Reference Electrode Filling Solution
-
Orion Reference Electrode Fill Solution, Na, 5 X 50 ml
Thermo Scientific Orion…selective electrodes with Thermo Scientific™ Orion™ ISE Filling Solutions. These solutions are specially formulated to work with the recommended ion selective electrodes and prevent electrode interferences from filling solution. Ion Selective Electrode Filling Solutions, 5 x 60mL…
-
Ion Selective Electrode (ISE) Chloride Reference Fill Solution
Agilent TechnologiesChloride reference fill solution. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.
-
Ion Selective Electrode (ISE) Sodium & Potassium reference Fill Solution
Agilent TechnologiesSodium and potassium reference fill solution. This product is only available to U.S. Domestic Customers. For research use only, not to be used in diagnostic procedures.
-
The Ricca Chemical potassium chloride with a composition of 80.26% water and 19.74% potassium chloride, is suitable for use in medicine and scientific applications. It can be stored at a temperature of 15 to 30 degree C. Filling solution for ROSS pH combination and reference electrodes
-
Orion™ pH Electrode Filling Solution
Thermo Scientific OrionUse Thermo Scientific™ Orion™ pH Electrode Filling Solution with pH electrodes and reference electrodes. Packaged as five 2 oz. (5 x 60mL) bottles.
-
Orion Filling Solution
Thermo Scientific OrionThermo Scientific Orion filling solutions for use with pH electrodes and reference electrodes. Filling solutions are packaged as five 2 oz. (5 x 60mL) bottles.
-
Orion™ pH Electrode Filling Solution
Thermo Scientific OrionUse Thermo Scientific™ Orion™ pH electrode filling solution with pH electrodes and reference electrodes. Packaged as five 2 oz. (5 x 60mL) bottles.
-
Fluoride Ion Electrode
Thermo Scientific Orion…seawater brines and it is approved by EPA, Standard Methods and AOAC for feeds Range saturated to 0.02 ppm Requires 4215F10 reference electrode. Uses 4215F20 fill solution Accessories: Fluoride standard, 0.1000 M ±0.0005 Fluoride standard, 100 ppm ±0.5 ppm 1 or 2 ppm Fluoride standard with…
-
Reference Fill Solution
OaktonThe Oakton 0.1M reference fill solution is mainly used with pH electrodes to ensure high performance and durability.
-
Nitrate Ion Electrode
Thermo Scientific Orion…4215F70 filling solution. Nitrate Standard: 0.1000 ±0.0005 Nitrate Interference Suppressor Solution Filling Solutions: For 4210S10 Combination Electrode use 4210S03 For 4210S11 and S12 Half Cell Electrodes use 4210S40 For 4215F60 Half Cell Reference Electrode use…
-
Ref Electrode Fill Sol F/Dbl Junct 5X60mL
Thermo Scientific OrionFilling solution for Double Junction, Double Junction KNIpHE™ electrodes. For use with pH electrodes and reference electrodes - only use ROSS filling solution (4153W50) with ROSS™ and ROSS Ultra™ pH electrodes to prevent damaging the ROSS electrodes 60 mL bottle
-
The Oakton KNO3 reference fill solution is mainly used with pH electrodes and reference electrodes to provide more reliable results. This solution is suitable for use in research facilities and general laboratories while conducting analytical chemistry experiments.
-
Electrode Care
Oakton…Accepts pH electrodes up to 12 mm in dia. General-purpose pH/ORP electrode cleaning solution removes build-up from electrodes and maintains electrode sensitivity. Storage and cleaning solutions come in 1 pint bottles. Use the reference fill solutions with refillable pH electrodes.
-
Calcium Ion Electrode
Thermo Scientific Orion…calcium in soils, fertilizers, feeds and plant tissues or calcium in boiler feed waters. Requires reference electrode 4215F10. Reference fill solutions: 4210B10 uses Optimum Results A filling solution (Thomas number 4209N38); 4210B13 uses 4 N KCl saturated with Ag (Thomas Number 4153H44) …
-
Sodium Ion Electrode
Thermo Scientific Orion…to 10 -6 M (saturated to 0.02 ppm) Model 4210E63 ROSS electrode requires Thomas number 4153Q87 or 0732K95 reference electrode. Uses Orion 900004 fill solution, order as 4153F22. Accessories: Sodium Ionic Strength Adjusting solution Sodium Standard, 100 ppm, calculated as Na+. Concentration…
-
Chloride Ion Electrode & Accessories
Thermo Scientific Orion…reference electrode. Includes 760 mm lead. Uses Orion 900002 fill solution, order as 4215F70. Accessories Chloride Standard, 0.1000 ±0.0005M Chloride Standard, 100.0 ±0.5 ppm Ionic Adjustment Solution, Sodium Nitrate Solution Acid and Iodide Reagent Reference…
-
… ISE TruLine Electrode features include: Wide selection of 15 electrodes for 16 different parameters 4 sensor technologies - gas sensing, polymer/PVC membrane, solid state, and glass sensor Integrated reference (i.e. combination/full-cell). Separate reference not needed …
-
Reference Electrodes For ISEs
Thermo Scientific Orion…has filling hole near top. Sleeve cannot be dislodged accidentally. Can be disassembled for cleaning. Electrodes potential characteristics match those of a saturated KCl calomel electrode. If filled with saturated KCl in place of 4215F20 refill solution, characteristics match those of reference…
-
ROSS® Ultra reference half-cell electrode with glass body and pin tip connector
Thermo Scientific Orion…a unique reference system developed by Thermo Scientific that offers longer life, greater stability, and fast results, regardless of sample composition or temperature. pH response is independent of temperature changes. Electrode Includes a 60 ml bottle of ROSS electrode fill solution, 810007.…
-
Electrolyte solution nonaqueous, 2 M LiCl in ethanol
MilliporeSigma…Applications portal to learn more. Synonyms: Lithium chloride solution Molecular Formula: ClLi Molecular Weight: 42.39 Linear Structural Formula: LiCl MDL Number: MFCD00011078 Application: Filling solution for reference electrodes used for titrations in nonaqueous solutions.
-
Combination Electrodes
Sensorex…glass electrode and sealed Ag-AgCl reference electrode in a single stem Range pH 0 to 14, 0° to 100°C Usable at pressures from 0 to 100 psig (690 kPa) Offered in choice of types, each with US Standard or BNC Connector The flat-tip electrodes have pH electrode and porous…
-
Combination pH Electrodes
Corning…cleaning; also usable with solutions containing suspended solids and non-aqueous solutions. Replacement Junctions (4136L60) Furnished immersed in KCl solution in screw cap bottle Flat Surface pH Combination (4136L96) AgCl internal reference sealed by ion exchange…
-
"Lithium chloride solution, 1 M in ethanol"
MilliporeSigmaFormula: LiCl Formula Weight: 42.39 CAS No.: 7447-41-8 Density: 0.83 g/mL at 20 °C Application: Filling solution for reference electrodes used for titrations in nonaqueous solutions Packaging: 250 mL in glass bottle
-
Synonyms: Potassium chloride solution saturated with AgCl Formula: KCl Formula Weight: 74.55 CAS No.: 7447-40-7 Density: 1.13 g/mL at 20 °C Application: Electrolyte filling solution for Ag/AgCl reference electrodes General description: Visit our Sensor Applications portal to…
-
ROSS® Sure-Flow® pH Electrodes
Thermo Scientific Orion…Electrode recommended for rugged conditions and field use. Epoxy Body Combination Semi-Micro Electrode recommended for small sample volumes and micro/titrations, includes bulb guard. Glass Body Reference Electrode is for all sample types, includes pin-tip connector and 3M KCl filling solution.
-
TRUEscience Redox Combination Electrodes
TRUEscience…Redox Combination Electrode S7. Ceramic single junction silver/silver chloride reference Electrode only with electrode soaker bottle and storage solution 1x TRUEscience Epoxy Redox Combination Electrode with S7 connector 1x soaker bottle filled with storage solution TRUEscience Item…
-
TRUEScience Ion Selective Electrodes
TRUEscience…Selective Electrodes (ISE) are rugged solid state sensors with built in Teflon double junction reference half cells that do not require filling solutions, membrane replacements or operator maintenance. These combination ISEs can be stored dry. The solid state sensor and maintenance free reference…
-
Solution Kits
Oakton…and activity. All solutions are supplied with MSDS (Material Safety Data Sheet) and have a value of 1000 ppm. Solution kits include replacement reference electrolyte, ISA (ionic strength adjustor)*, calibration standard, and filling pipette. Kits for solid-state electrodes also include polishing…
-
pH Elect. Calomel SJRG
OaktonThese electrodes are liquid-filled and refillable glass-bodied electrodes which allow the user to decide which application specific reference solution fits the need. Ideal for solutions containing organics Annular-type junction provides faster electrode response
-
ROSS® Ultra Refillable Glass Triode
Thermo Scientific OrionpH and temperature measurement with one electrode Versatile with chemically compatible glass body, refillable with ROSS 3M KCL solution or a fill solution compatible to your sample type Fast pH response even in samples at varying temperatures Compatible with Mettler-Toledo TM Five and Seven…
-
Star A325 pH/Conductivity Portable Multiparameter Meter
Thermo Scientific Orion…4.01 Buffer Pouches; 910710 pH 7.00 Buffer Pouches; 911010 pH 10.01 Buffer Pouches; 810001 ROSS Electrode Storage Solution, 475mL; 01100710 Conductivity 1413uS/cm Standard Pouches; 911110 Rinse Solution Pouches; STARA-CS Star A Hand-Held Meter Hard Carrying Case; STARA-AR Star A Hand-Held Meter…