Pressure Reaction

Compare Tool

Select up to 3 products

Pressure Reaction
1 - 32 of 203
Sort
View
Show
  • pressurization or contents release, allowing many test parameters Reaction vessels are available in three standard capacities: 3 oz., 6 oz. and 12 oz. CAUTION: safety precautions should be used with glass under pressure. Maximum safe pressure depends on service conditions. Pressure

  • …6384, 6386, 6388, 6423, 6425, 6427, or 6429 reaction flasks. Duran flange supplied with a shallow O-Ring groove for use with mating grooved flask. #15 Ace-Thred center and various #15 and #7 side necks available allow connections under pressure conditions without danger of blowout. For connectors,…

  • Adapter permits rotary evaporation of the contents of any of our CG-1880 pressure vessels after the reaction is complete. Adapter can also be connected to any vacuum line having a 24/40 port or used in conjunction with a CG-1014 adapter to connect to hoses. Eliminates the need to transfer samples…

  • …wall pressure vessels have an internal thread for use with PTFE bushings as pressure seals. The unique design allows hand tightening and loosing for easy access into the vessel. O-ring is positioned on the bushing above the thread for improved sealing. Vessels are useful for pressure reactions and…

  • …a high capacity outlet. BUBBLERS, PRESSURE RELEASE, Used for the purging of AIRFREE® or vacuum apparatus with an inert gas. The pressure release valve is connected on one side to the low pressure gas source and the other side to a manifold or reaction vessel. The check valve prevents oil and…

  • Moisture test receiver utilizes Ace-Thred bushings to achieve a 45psi @ 100 degrees C pressure rating when used in conjunction with Ace pressure reactors. Graduated receiver in 1ml subdivisions with PTFE bottom outlet stopcock. See also our 6024 series pressure condenser.

  • Pressure reactor thermowell has a shoulder that rides against bottom of a bushing to prevent blowout. Inner diameter of well is approximately 5mm and is available in many lengths. Order thermowell and bushing separately.

  • Blood Pressure Kit

    GSC International, Inc.

    Our blood pressure kit includes an aneroid sphygmomanometer, a stethoscope, extra ear buds, an extra diaphragm, and a carrying case. Use this kit to accurately measure blood pressure. Instructions included. PRODUCT WARNINGS WARNING: This product can expose you to chemicals…

  • …allows the sampleto escape if the pressure should exceed 150 atmospheres. The use ofhigh pressure capsules in DSC permits suppressing the endothermicsignal resulting from the volatilization of sample material or fromthe volatilization or decomposition of reaction by-products. Highpressure capsules…

  • pressure reactor system designed to perform low to moderate positive pressure reactions, synthesis and catalysis. Reactor capacities range from 500ml to 5000ml and use Ace-Threds to achieve a leak-tight system. One-piece design features a 25mm center opening and has a higher allowable pressure

  • pressure reactor system designed to perform low to moderate positive pressure reactions, synthesis and catalysis. Reactor capacities range from 500ml to 5000ml and use Ace-Threds to achieve a leak-tight system. One-piece design features a 25mm center opening and has a higher allowable pressure

  • Complete, two-piece, plain flask, pressure reactor system designed to perform low to moderate positive pressure reactions, synthesis and catalysis. Reactor capacities range from 500ml to 5000ml and use Ace-Threds to achieve a leak-tight system. Two-piece (flanged flask and head) design allows the…

  • Complete, two-piece, jacketed flask, pressure reactor system designed to perform low to moderate positive pressure reactions, synthesis and catalysis. Reactor capacities range from 500ml to 5000ml and use Ace-Threds to achieve a leak-tight system. Two-piece (flanged flask and head) design allows the…

  • …to escape if the pressure should exceed 150 atmospheres. The use of high pressure capsules in DSC permits suppressing the endothermic signal resulting from the volatilization of sample material or from the volatilization or decomposition of reaction by-products. High pressure capsules permit the…

  • Complete inlet and outlet manifold set for use with 10L to 20L flasks with 1in beaded pipe connections, 10PSI relief pressure, M16x1 circulator connections.

  • …featuring a one-piece, unjacketed, pressure vessel with a combination Ace-thred valve and 28/15 o-ring ball joint bottom outlet. Vessel top has a 25mm Ace-thred center neck and various multi-neck configurations. System is designed to perform positive pressure reactions at up to 45 psi at 100 degrees…

  • pressure reactor system designed to perform low to moderate positive pressure reactions, synthesis and catalysis. Reactor capacities range from 500ml to 5000ml and use Ace-Threds to achieve a leak-tight system. One-piece design features a 25mm center opening and has a higher allowable pressure

  • Complete, two-piece, plain flask with bottom outlet, pressure reactor system designed to perform low to moderate positive pressure reactions, synthesis and catalysis. Reactor capacities range from 500ml to 5000ml and use Ace-Threds to achieve a leak-tight system. Two-piece (flanged flask and head)…

  • Complete, two-piece, jacketed flask with bottom outlet, pressure reactor system designed to perform low to moderate positive pressure reactions, synthesis and catalysis. Reactor capacities range from 500ml to 5000ml and use Ace-Threds to achieve a leak-tight system. Two-piece (flanged flask and…

  • …sample to escape if the pressure shouldexceed 150 atmospheres. The use of high pressure capsules in DSCpermits suppressing the endothermic signal resulting from thevolatilization of sample material or from the volatilization ordecomposition of reaction by-products. High pressure capsulespermit the…

  • Sparger tube for use in #15 Ace-Thred with either ONE-PIECE or TWO-PIECE Reactors. Consists of a closed bottom, 1/2" O.D. tube with a 1/8" I.D. bore. Bottom of tube has two 3/64" holes, 90 degree apart; top has a 5/16" male thread for connecting to bot

  • …PTFE bushings. IMPORTANT NOTICE: ALL CHEMGLASS PRESSURE VESSELS ARE TESTED AT 150 PSI, OR APPROX TWO AND ONE-HALF TIMES THEIR RECOMMENDED WORKING PRESSURE. HOWEVER, CHEMGLASS DOES NOT GUARANTEE THE VESSEL FROM BREAKING UNDER PRESSURE, DUE TO THE NATURE OF MATERIAL AND CONDITIONS BEYOND OUR…

  • Reaction Kettle Clamp

    Wilmad-LabGlass - SP Scienceware

    This reaction vessel clamp for O-rings and flat flanges is a cast bronze ring with a black oxidized finish. Three insulated, spring activated clamping arms fit beneath the flange of the flask body. Simple pressure on the heat-resistant fiber knobs and a twist, permit attachment or removal.

  • …in alcohol and ether. Clarity 1% w/v aqueous solution is clear without any haziness after autoclaving at 15 lbs pressure (121ºC) for 15 minutes. Reaction Reaction of 2% w/v aqueous solution at 25ºC. Storage and Shelf Life Store below 30°C. Use before expiry date on the label.

  • …surfaces. Plain flat or grooved PTFE gaskets reduce breakage and make an effective seal. Our flat, exclusive FETFE gasket provides a leak-free seal with slight clamp pressure. These are designed especially for use with our conical or flat ground flange style reactor flasks from 500mL up to 4000mL.

  • 5mm O.D. Quick Pressure Valve (QPV) NMR Sample Tubes

    Wilmad-LabGlass - SP Scienceware

    …catalysis, gas-liquid phase reactions, air sensitive samples and elevated temperature studies using low boiling point solvents. Due to the nature of glass, Extreme Caution should be exercised when using at elevated or reduced pressures as performance of tubes under pressure or vacuum cannot be…

  • Stainless Steel McCarter Reaction Clamps

    Wilmad-LabGlass - SP Scienceware

    …two pieces of glass with flat flanges of the same diameter, these stainless steel horseshoe-shaped clamps are uniquely designed. Adjustable tension springs that secure even pressure over the flange area, may be slid on or off easily - thus facilitating assembly and disassembly of apparatus setups.

  • …Clamping which is positive and quick-acting; easier to apply and remove than two-piece clamps Spring-action lugs which cannot crack flange Fiber knobs which are heat-resistant Ribbed Teflon gaskets, which reduce clamp pressure required for complete seal Maximum temperature 200°C

  • SYNTHWARE cylindrical reaction tube with standard taper outer joint and 2mm bore glass stopcock sidearm. Useful for sample storage and simple reactions. The stopcock has a constant pressure retention device.

  • Complete reaction assembly available in 12L, 22L, 50L and 72L spherical flask capacities. Unit is complete with heating mantle and controls, mechanical stirrer and controls, pressure equalizing funnel and pilot plant condenser.

  • SYNTHWARE round bottom two neck reaction flask with standard taper outer joints and 2mm bore glass stopcock sidearm. Useful for sample storage and simple reactions. The stopcock has a constant pressure retention device.

  • SYNTHWARE round bottom single neck reaction flask with a standard taper outer joint and a 2mm bore glass stopcock sidearm. Useful for sample storage and simple reactions. The stopcock has a constant pressure retention device.

Compare Tool

Select up to 3 products

Please Log In