Pressure Filtration

Compare Tool

Select up to 3 products

Pressure Filtration
1 - 32 of 218
Sort
View
Show
  • Pressure filtration devices with a sample loading cylinder are suitable for batch filtration of samples from 20 ml. Devices without infusion cylinders are connected inline and are suitable for larger volumes of several liters. Pressure filtration devices with a sample loading cylinder are…

  • High Quality, Corrosion-Resistant Funnel for Rapid Batch Filtration Stainless steel construction offers excellent chemical resistance.   Convenient hand tightening makes filter changing easy. Pall Laboratory products are designed for laboratory applications only. This…

  • Adapters are used for reduced pressure filtration with plain stem buchner funnels. Top is tooled to accept the listed size of pluro-stopper. Serrated hose connection has an O.D. of 10mm at the largest serration. FOR PLURO STOPPERS SEE CG-1401.

  • PVDF Filtration

    NEST Scientific USA

    …transparent polystyrene funnel connected to a receiving bottle by a connector. The disposable vacuum filter utilizes a vacuum pump to provide pressure differentials for processing large volumes of tissue culture fluids and other laboratory fluid solutions and the volume of processed samples could…

  • MCE Filtration

    NEST Scientific USA

    …transparent polystyrene funnel connected to a receiving bottle by a connector. The disposable vacuum filter utilizes a vacuum pump to provide pressure differentials for processing large volumes of tissue culture fluids and other laboratory fluid solutions and the volume of processed samples could…

  • Adapter used for reduced pressure filtration with plain stem buchner funnels. Top is flared to accept the listed size pluro stopper. The hose connection has an O.D. of 10mm at the largest serration. ADAPTER IS NOT SUPPLIED WITH RUBBER PLURO STOPPER, See CG-1401.

  • Used for reduced pressure filtration with 7186 style, plain stem Buchner funnels. Top is tooled to accept a pluro stopper, bottom has a joint. Serrated hose connection has a second ring of 13.5mm O.D. Inserting the recommended size pluro stopper and th

  • Adapter used for reduced pressure filtration with plain stem buchner funnels. Top has a HEAVY DUTY tooled flare to accept the listed size pluro stopper. Hose connection is 10mm OD at the largest serration. ADAPTER IS NOT SUPPLIED WITH RUBBER PLURO STOPPER. CG-1052-A-14 Accepts up to…

  • For positive pressure filtration of materials up to 15 psi. Connection between the funnel and adapter is made by an o-ring joint which permits a larger, grease free opening for sample retrieval. The 24/40 lower inner standard taper joint has an outlet for connection to a vacuum source. Complete item…

  • …processing Short filtration time – under 20 minutes, even for 6 samples Pump to speed up filtration process & washing Efficient Operation Unclog crucibles with air pump to improve filtration quality Electronic setting of counter pressure Recommendations…

  • …three-place manifold, for microbiology monitors and analytical funnels AS 300 and 600 Series The stainless steel manifold for three or six filtration units is fitted with stainless steel units. The apparatus can be autoclaved and sterilized by dry heat at up to 180°C. Suitable only for vacuum…

  • …via 0.02 µm PTFE vent Filters are designed as positive pressure devices for use with a peristaltic pump or pressure vessel to eliminate the denaturation of proteins which may occur when using vacuum filtration devices. Ordering information: Individually packaged units come…

  • …helping HVAC field technicians determine the performance of heating and cooling systems. This handheld meter measures differential and static pressure, and calculates air velocity and flow. Meters are heavy duty, easily configurable, and feature a large backlit LCD. View measurement data in…

  • … 90mm, 142mm, 293mm Filter Diameters Available in Type 304ss and 316ss Large Sanitary Stainless Steel Pressure Filter Holders for batch type laboratory filtration using disc media. Sanitary connections can be completely disassembled for thorough cleaning. Clean holder design minimizes…

  • …transparent polystyrene funnel connected to a receiving bottle by a connector. The disposable vacuum filter utilizes a vacuum pump to provide pressure differentials for processing large volumes of tissue culture fluids and other laboratory fluid solutions and the volume of processed samples could…

  • AS300/3 Multiple Vacuum Filtration Apparatus, three-place vacuum filtration system, stainless steel 500 ml, 47/50 mm, support screen AS300/3 Multiple Vacuum Filtration Apparatus, three-place vacuum filtration system, stainless steel 500 ml, 47/50 mm, support screen The apparatus can be autoclaved…

  • AS600/3 Multiple Vacuum Filtration Apparatus, six-place vacuum filtration system, stainless steel 500 ml, 47/50 mm, with support screen AS600/3 Multiple Vacuum Filtration Apparatus, six-place vacuum filtration system, stainless steel 500 ml, 47/50 mm, with support screen AS 600 Series The…

  • …lateral wicking Unlike standard holders, the Multi-Media Pressure Sealing Filter Holder has a dual sealing system which allows the use of a broad range of media thickness, including pads. This enhanced pressure sealing system can accomodate media thickess up to 3mm without compromising…

  • Large Filtration Area for Easy Operation and Fast Liquid Flow Economical for small-volume (10 to 100 mL) filtration. Accepts 25 mm filter discs. Luer inlet and outlet fittings provide easy connections. Delrin (acetal resin) construction provides broad chemical compatibility and…

  • High-quality and durable, this 47mm stainless steel in-line pressure holder can operate at high pressures up to 1420 psi (9.8 MPa). Standard FPM(Viton) O-rings are compatible with many aggressive liquids and gases. Type 304ss body and type 316ss sintered support screen. An optional…

  • …and 293mm filter diameters Available in type 304ss or 316ss Large Stainless Steel Pressure Filter Holders are offered in various sizes for batch type laboratory filtration or continuous filtration operations using disc media. Advantec holders have been designed to minimizes resistance and…

  • Use these electropolished stainless steel pressure vessels to propel filtration fluids through pressure holders by applying external pressure from compressed gases. Increasing pressure increases the efficiency of the EPR (ethylene propylene rubber) O-ring seal. Vessels feature 5-7⁄8"x…

  • …Resistant Packed: 50/Bag-In-Box; 2000/CS Meets ASTM Level 2 Requirements: BFE (Bacterial Filtration Efficiency): >99% PFE (Particle Filtration Efficiency): >99% Fluid Resistance: 120 mm Hg Differential Pressure: 4.53 mm H2O/cm2 Flammability: Class 1

  • Adapter used for reduced pressure filtrations using plain stem buchner funnels. Stopcock permits control of vacuum source. Top of adapter is tooled to accept the listed size of pluro-stopper. NOTE: ADAPTER IS NOT SUPPLIED WITH RUBBER PLURO-STOPPER, SEE CG-1401

  • Ultraclean or sterilize liquids or gases by pressure filtration Autoclave with Durapore filter in­place 316 stainless steel with anodized aluminum legs

  • Sartolab P20

    Sartorius

    Sartolab P/P20/P20+: Ready-to-use pressure filtration units for sterilie filtration of tissue culture solutions from 100 ml to 5 liter of buffer, media, and aqueous solutions. For use with laboratory pumps.

  • XX4304700

    MilliporeSigma

    Ultraclean liquids or gases in-line by pressure filtration. Open for filter change without disturbing attached plumbing. Polypropylene filter holder with stepped hose connector at both ends for easy installation

  • XX6702500

    MilliporeSigma

    …cleaning. Solvent dispenser has an integral, stainless steel membrane filter holder (XX4002500) which can also be used by itself for in-line pressure filtration of gases Includes filter support screens, fluoroelastomer filter holder gaskets and pressure rated polyethylene tubing (6-Feet)

  • Polysulfone Bottle-Top Filter Holders

    Thermo Scientific Nalgene

    …maximum flow rate and throughput Molded-in graduations Cover ports accommodate 1/4” i.d. tubing for flushing procedures, sterile venting or pressure filtration Without required membrane, accepts 47 or 50 mm membrane * Use only sterile bottles designed for use with a vacuum

  • Buchner Filter Funnel with a sealed in Perforated Plate Capacity: Available in sizes ranging from 60-600 mL Glass Disk Size: Available in sizes ranging from 42-90mm. Not recommended for filtration where pressure will exceed 15 psi

  • …in fabrication of special glass apparatus. Available in F, M, C and XC porosities. Pressure Limits: Fritted glassware is designed for low pressure vacuum filtration or gas flow. The MAX differential pressure should not exceed 15 PSI. Thermal Limits: Fritted glassware should not be exposed to…

  • Buchner Funnel, Fritted Disc, Inner Joint Capacity: Avilable in multiple capacities ranging from 15-600mL Joint: Multiple Joint sizes available Frit OD: ranging form 20-90mm Porosity: Medium and Course available Not recommended for filtration where pressure will exceed 15 psi

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.