Luer Fittings

Compare Tool

Select up to 3 products

Luer Fittings
33 - 64 of 101
Sort
View
Show
  • Disposable Plastic Syringes

    National Scientific

    For use with syringe filters No rubber or synthetic plunger gaskets No silicone oil lubricant Luer-Slip or Luer Lok® fittings Two-part, all plastic syringes have polypropylene barrels and either polypropylene or polyethylene plungers for a wide range of chemical…

  • Omnifit® T-Series Solvent Waste Caps without Valve/Filter

    Diba

    …male Luer fittings to connect various tubing sizes Anti-twist design The T-series solvent bottle caps help contain vapors and protect lab staff from exposure to toxic fumes. Push through 1/8" OD semi-rigid tubing for a liquid- and vapor-tight seal or use standard male Luer fittings to…

  • Whatman Aqueous In-Line Filter/Degasser (IFD)

    GE Healthcare

    …polypropylene construction enables reliable filtration Can be integrity-tested with the bubble point method Includes end fittings – for replacements, see our IFD end fitting kit Faster than traditional methods of HPLC mobile phase preparation, saving time in the laboratoryProvides pure…

  • Omnifit® T-Series Solvent Waste Caps with Vent

    Diba

    Connect a vapor trap using the vent port to prevent solvent vapors from escaping Use without any fittings or use male Luer fittings to connect various tubing sizes Anti-twist design The T-series solvent bottle caps help contain vapors and protect lab staff from exposure to toxic…

  • Omnifit® T-Series Solvent Bottle Caps with Check Valve and Filter

    Diba

    …filter allow pressure equalization for safe solvent delivery Filter prevents particulate contamination Use without any fittings or use male Luer fittings to connect various tubing sizes Anti-twist design The T-series solvent bottle caps help contain vapors, protect lab staff from…

  • Aqueous IFD And Solvent IFD In-Line Filters/Degassers

    GE Healthcare

    …solvents. Both devices have a polypropylene housing, the circumference of which is sealed by a security ring, fittings to accommodate 1/8” tubing and an air vent on the inlet with luer lock cap to enable priming. The in-line filters work on the principle of “bubble point” - the…

  • Perfektum Needles

    Cadence Science

    Stainless steel with chrome-plated hub With regular medical point; 12-14° bevel. Hub flange engages socket of luer tip. Box of 12. Gage x length given in listings. Interchangeable fit with Luer Lock or Luer Slip syringes.

  • SLFHR04NL

    MilliporeSigma

    …a Hydrophobic PTFE membrane, for non-sterile filtration, has a 0.45 µm pore size used in clarification of organic solvents. 4 mm Millex filters are perfect for small sample sizes Non-sterile with excellent solvent resistance Male Luer slip fitting outlet is stepped Pack of 100

  • Whatman Polycap HD

    GE Healthcare

    …temperatures Sturdy construction leads to high flow and high retention capacity Can be autoclaved with steam at 121°C for 20 min Manual vent with luer lock to bleed air from upstream or serve as an injection or sample port Available in 0.45, 1.0, 5.0, 10, or 20 µm retention rating, as well as a…

  • Millex-HP 0.45 µm, PES 33 mm, non-sterile

    MilliporeSigma

    …instrument analyses. Connections, Inlet/Outlet: Female Luer-Lok/Male Luer slip Filter Code: HP Fitting Inlet: Female Luer-Lok® Fitting Outlet: Male Luer slip Housing Material: Polypropylene (PP) Color Code: …

  • Drenchers

    DWK Life Sciences (Wheaton)

    Intended for safe animal nose and mouth feeding, the drenchers have straight or bent shapes with rounded extremities Luer Lock fixture for tight fitting on syringe nozzle Stainless steel material, autoclavable

  • Digital Microdispenser Accessories

    Drummond

    …has Luer slip fitting at dispensing tip; side arm takes 2 mm bore tubing for connection to suitable reservoir Valve diaphragm is ethylene polypropylene rubber Kit includes 7691L60 Pall Valve; stainless steel inlet sinker; 760 mm length of 3/32” bore vinyl tubing; Luer pipet…

  • E-Cube Culture System

    Corning

    …female barbed luer fittings; 2 male luer plugs; 2 interlink injection sites; 1 sleeve of blunt plastic cannulas and 3 1.0” ID x 1.25” OD, 1/8” thickness O-rings. 45 mm Polypropylene cap is autoclavable and comes with two 15.24 cm stainless steel tubes. Cap fits Corning glass…

  • Scienceware® Varipet® Pipettors

    Bel-Art - SP Scienceware

    … Teflon® Tip Varipet® Pipettor has excellent chemical resistance because the fluids only contact the borosilicate glass and Teflon® Luer Lock Varipet® Pipettor is supplied with a chrome-plated steel Luer lock fitting, complete with removable cannula for general use Autoclavable

  • Hypodermic Needles

    Cadence Science

    …304 stainless steel tubing which must pass our rigorous inplant quality control prior to acceptance and use. Standard luer hubs comply with luer taper specifications ISO 594. This assures an interchangeable fit mating with luer slips and luer locks. Contoured hub cavity facilitates cleaning.

  • SurGuard2™ Safety Hypodermic Needles

    Terumo Medical Corporation

    …Sheath Bevel-up, sheath right needle orientation, especially useful for low-angle injections Ratchet mechanism, allows for precise positioning of sheath so as not to obscure injection site Standard hub fits all luer lock and luer slip syringes Large selection of sizes from 18G to 30G

  • 2mL Luer-Lok Syringe

    PerkinElmer

    Key Features Include: Precision-machined plunger and barrel Excellent fitting and tightness Permanent, high-visibility graduations

  • Headspace/Soil Gas Syringes

    SGE

    Available in 5mL and 10mL capacities, the Gas Tight syringes are fitted with a valve (SVLL) and a special Luer Probe with a side hole for efficient sample intake.

  • PTFE Stopcock Valve, 2 Way

    Ace Glass

    PTFE stopcock valve, 2-way, one 1/4 inch male luer port and one 1/4 inch male NPT port, 0.046 orifice. PTFE valve used with NPT fittings. Various ends available (male and female NPT, luer, 1/4" tube and 1/4"-28 UNF). IPS PTFE Stopcocks made of virgin PTFE. Compression ferrules made of virgin PTFE.…

  • Yale Reusable Glass Syringes

    BD

    Serially Numbered, Luer Slip Luer slip tip Barrel and plunger individually ground for precise fit and serially numbered Syringes are individually calibrated and have glass Luer slip tip. 1/4 cc, 1/2 cc, 1 cc and 2 cc syringes graduated in minims as well as cc. 1 cc syringe has…

  • Minipet™ Pipettors

    Bel-Art - SP Scienceware

    … Aqueous Minipet Pipettors are autoclavable and can be used with a Luer lock manifold for multi-well plate work; supplied with a chrome plated check valve, Luer lock fitting, Buna-N-seals, stainless steel spring, and Luer lock cannula, 45.7cm long (18”), 3.2mm (1/8") I.D. silicon…

  • VersaBarb™ and Spigot Technology

    Foxx Life Sciences

    …which can damage the seal. The spigot opening features 5/8" and 3/4" hose barbs for tube attachments, as well as an internal luer taper to fit a male barb adapter. The leakproof VersaBarbs provide bottom connection options for any standard carboy with a spigot. VersaBarbs are…

  • Gradient Makers

    C.B.S. Scientific

    …outlets. Gradient flow is controlled by a PTFE valve centered between the two chambers. The outflow channel is fitted with a male luer adapter which can be used with any needle or luer valve. Form all types of gradients for acrylamide gel electrophoresis, as well as sucrose or cesium…

  • Laboratory Pipetting Needles with Blunt Ends

    Cadence Science

    …steel cannulae. Catalog numbers 7950 to 7957 needles are fitted with stainless steel hubs for special applications with corrosive materials or critical procedures. Catalog numbers 7930 to 7942 needles are fitted with standard nickel plated luer hubs. These needles are used in conjunction with both…

  • Stainless Steel Syringe Filter Holders

    Advantec MFS

    …13mm and 25mm type 304 stainless steel syringe holders are economical and re-usable thereby reducing waste. Luer-lock fittings are compatible with standard syringes. Luer slip outlet. PTFE O-ring and gasket. The units can be sterilized by standard procedures including autoclave. Can be tightened…

  • 10µL to 500µL Gas Tight Syringes

    SGE

    …performance and superior quality. Constructed from borosilicate glass, PTFE plunger tips and Kel-F® or PTFE Luer cones where applicable Assembled with an interference fit between plunger tip and barrel to effect the gas sealing properties of the syringe Plungers are replaceable on…

  • NMR Funnel Polypro 200mm

    DWK Life Sciences (Kimble)

    … The lower column fitting with a Luer outlet is molded polypropylene with a specially designed recess to securely hold a porous polyethylene bed support or a glass wool plug Supplied unassembled with a column, polypropylene reservoir and lower column fitting Polyethylene bed supports…

  • Manual Syringes with Valves

    SGE

    …needle syringes. 1186G40 (031910): Push button valve with Luer Lock termination. Suits 5mL-2L syringes with removable Luer Lock or removable needle. 1186G41 (031915): Luer Lock valve for any Luer Lock and Luer Tip syringes or other Luer devices. Ideal when fast needle changeover is needed.

  • Chemically Resistant PFA In-Line Filter Holders

    Advantec MFS

    …on PFA47 is ETFE glass fiber filled PFA. Both units come standard with FFKM o-rings. Connections: PFA25 has Luer-lock inlet and Luer slip outlet connections that fit standard syringes. PFA47 has combination 1/4" NPTM, 1/4" tubing adapter inlet/outlet. Replacement parts and optional o-ring…

  • Filter Holder Accessories

    Sartorius

    Accessories for Sartorius Brand Filter Holders.

  • Inert Valve Hv 3-3

    Hamilton

    …interchange a wide variety of fittings, adapters and tubing, including male and female luers, FEP tubing assemblies, and adapters which thread directly into the valve providing an endless variety of valve configurations for any flow application. Hamilton (HV) fittings and adapters are installed…

  • Maroon PVDF Syringe Filters, 0.22 µm, 30 mm

    PerkinElmer

    …Effective Filtration Area (cm2): 5.39 Pore Size (µm): 0.22 µm Holdup Volume (µl): Sample Volume (mL): Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50 °C Maximum Operating Pressure: 6 bar Typical Applications: High particulate…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.