Ion Selective Electrodes

Compare Tool

Select up to 3 products

Ion Selective Electrodes
1 - 32 of 139
Sort
View
Show
  • ISE-08 Sodium Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-08 Sodium Ion-Selective Electrode (ISE) is an affordable laboratory or field electrode offering good performance and longevity for Sodium analysis in many water applications like food & beverage analysis. Specifications: Sensor Type: Solid State (glass membrane) …

  • Orion Ion Selective Electrodes (ISE)

    Thermo Scientific Orion

    Measurements using an ion selective electrode (ISE) are applicable in virtually every laboratory. ISEs can be used to measure ion concentrations in water, food, pharmaceuticals and biological samples. Ion selective electrodes can be used as endpoint indicators or to perform direct measurement and…

  • ISE-04 Nitrate Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-04 Nitrate Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance nitrate analysis performance for many water applications such as drinking water, agriculture applications and food/beverage. Specifications: …

  • ISE-07 Ammonia Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-07 Ammonia (NH3) Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering convenient replaceable membrane modules and excellent performance. Specifications: Sensor Type: Gas-Sensing - glass pH with gas-permeable membrane …

  • Thomas Brand Mercury Ion Electrodes

    Thomas®

    …reference electrode. A separate reference electrode can be used with more than one type half-cell ISE, saving some cost. Double junction reference electrodes allow the use of special outer chamber electrolyte formulas which can avoid or reduce interferences from other ions. Electrodes measure…

  • Ion Selective Electrodes

    WTW

    Ion selective electrodes for the electro-chemical concentration determination of selected ions - combined electrodes as well as half cells available. Cost-effective process with few samples Wide selection of electrodes for different ions Easy handling by combined electrodes WTW…

  • Ion Selective Electrodes

    Oakton

    Oakton has a large selection of ion-selective electrodes (ISEs) to suit a wide variety of applications. Each electrode has a typical response time of 20 to 30 seconds but will vary with solution concentration. Oakton offers four electrode types: membrane, solid-state, gas sensing, and glass bulb.…

  • ISE-03 Silver Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-03 Silver Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Silver analysis performance for many water applications. Specifications: Sensor Type: Solid State Range: 0.01-107,900 ppm Sample pH…

  • ISE-02 Chloride Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-02 Chloride Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Chloride analysis performance for many water applications. Specifications: Range: 1.8-35,500 ppm Sample pH Range: 2-12 Slope: 56…

  • ISE-01 Fluoride Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-01 Fluoride Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Fluoride analysis performance for many water applications. Specifications: Sensor Type: Solid State (LaF Crystal) Range: 0.02 to…

  • ISE-06 Calcium Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-06 Calcium Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Calcium analysis performance for many water applications such as beverages, milk, aquariums, and water hardness evaluations. Specifications: …

  • Thomas Brand Nitrate Ion Electrodes

    Thomas®

    …contact electrodes require no preconditioning. Simply place electrode in a sample and read results. This innovative technology offers unlimited shelf life and greater measurement stability. Thomas also offers a half-cell version that requires a single junction reference electrode. A separate…

  • ISE-05 Potassium Ion-Selective Electrode

    labForce (a Thomas Scientific Brand)

    The labForce ISE-05 Potassium Ion-Selective Electrode (ISE) is a general purpose, laboratory or field electrode offering affordable, low maintenance Potassium analysis performance for many water applications such as wastewater, agriculture applications and food/beverage. Specifications: …

  • "Calcium ionophore II, Selectophore™, function tested"

    MilliporeSigma

    …460.69 CAS No.: 74267-27-9 Application: Lipophilic ionophore for Ca 2+ -selective electrodes with detection limit in the sub-nanomolar range. Extremely efficient carrier of Ca 2+ -ions; induces a selectivity in membranes for Ca 2+ over Mg 2+ by a factor of about 10 4 . General description:…

  • High Performance Ammonia Electrode

    Thermo Scientific Orion

    …membrane on the electrode. The ammonia electrode has a waterproof BNC connector that can be used with any meter that has a BNC input and ensures a waterproof and secure connection when used with the Orion Star Series meters. Easy electrode maintenance with a translucent electrode body with fill…

  • Thomas Brand Nitrite Ion Electrodes

    Thomas®

    …contact electrodes require no preconditioning. Simply place electrode in a sample and read results. This innovative technology offers unlimited shelf life and greater measurement stability. Thomas also offers a half-cell version that requires a single junction reference electrode. A separate…

  • Thomas Brand Cadmium Ion Electrodes

    Thomas®

    …reference electrode. A separate reference electrode can be used with more than one type half-cell ISE, saving some cost. Double junction reference electrodes allow the use of special outer chamber electrolyte formulas which can avoid or reduce interferences from other ions. Electrodes measure…

  • IntelliCAL ISENH3181 Ammonia Ion Selective Electrode (ISE) Replacement Membranes

    Hach

    Replacement membrane modules for IntelliCAL ISENH3181 Ammonia ISE only. Modular, easy to maintain design Pack of three membranes extends the time between replacement orders

  • Thomas Brand Water Hardness Ions Electrodes

    Thomas®

    …contact electrodes require no preconditioning. Simply place electrode in a sample and read results. This innovative technology offers unlimited shelf life and greater measurement stability. Thomas also offers a half-cell version that requires a single junction reference electrode. A separate…

  • LIS Chamber

    Hach

    LIS Sample Chamber for sensION instruments (NOT FOR USE WITH HQd). For low ionic strength samples. Isolates samples from atmosphere. Accurate Easy to Use Rugged and Durable Flexible Note: this is the LIS Chamber only.  

  • Sodium Ion Electrode

    Thermo Scientific Orion

    ROSS, Half Cell ISE For determination of Na+ ion activity in concentrations from saturated to 10 -6 M (saturated to 0.02 ppm) Model 4210E63 ROSS electrode requires Thomas number 4153Q87 or 0732K95 reference electrode. Uses Orion 900004 fill solution, order as 4153F22. Accessories: Sodium…

  • Thomas Brand Potassium Ion Electrodes

    Thomas®

    …contact electrodes require no preconditioning. Simply place electrode in a sample and read results. This innovative technology offers unlimited shelf life and greater measurement stability. Thomas also offers a half-cell version that requires a single junction reference electrode. A separate…

  • Thomas Brand Bromide Ion Electrodes

    Thomas®

    …reference electrode. A separate reference electrode can be used with more than one type half-cell ISE, saving some cost. Double junction reference electrodes allow the use of special outer chamber electrolyte formulas which can avoid or reduce interferences from other ions. Electrodes measure…

  • Thomas Brand Chloride Ion Electrodes

    Thomas®

    electrode. A separate reference electrode can be used with more than one type half-cell ISE, saving some cost. Double junction reference electrodes allow the use of special outer chamber electrolyte formulas which can avoid or reduce interferences from other ions. Dry contact electrodes require…

  • Thomas Brand Ammonia Ion Electrodes

    Thomas®

    Traditional Gas Sensing Type ISE High accuracy Robust, rugged and reliable Combination Electrodes measure 12 mm diameter x 145 mm length and are equipped with a one meter cable, BNC type connector, 2 membrane caps and filling solution.

  • REF-01 Double Junction Reference Electrode

    labForce (a Thomas Scientific Brand)

    The labForce REF-01 Double Junction Reference Electrode Reference Solution: options of the first salt bridge solution and the second salt bridge solution Reference Electrode: Ag/AgCl Junction: Ceramic Dimension: Φ12x155mm Compatible labForce meters: ISE500 and M1000. May…

  • Ammonia Ion Electrode Accessories

    Thermo Scientific Orion

    …with threads to mount membrane. Nitrate Test Kit Permits use of Ammonia Electrodes to measure nitrate Kit solutions are used to make sample basic and then to convert nitrate to ammonia for measurement. Ions such as chloride, which normally interfere, have no effect on the measurement.…

  • HI 9829 Multiparameter Meters

    Hanna

    …to 12 parameters simultaneously from up to 15 user selectable parameters. Combined with one of the HI 76x9829 series probes, the HI 9829 can measure water quality parameters such as pH, ORP, conductivity, turbidity, temperature, ions ions ammonium, nitrate, chloride (NH4+, NO3-—N or Cl-),…

  • ION 700 Benchtop Meters

    Oakton

    …benchspace Store and recall up to 100 data sets Ion 700 meter measures pH, mV, relative mV, and temperature while adding ion measurement capabilities. Ion concentration is directly read in ppm for easy use. Verify electrode operation while taking measurements with the dual ppm and mV…

  • Nitrate Ion Electrode

    Thermo Scientific Orion

    …filling solution. Nitrate Standard: 0.1000 ±0.0005 Nitrate Interference Suppressor Solution Filling Solutions:  For 4210S10 Combination Electrode use 4210S03  For 4210S11 and S12 Half Cell Electrodes use 4210S40  For 4215F60 Half Cell Reference Electrode use 4215F70

  • Thomas Brand Sodium Ion Electrodes

    Thomas®

    …Reliable Economical Glass sensor electrodes are the best available method for measuring sodium ions. They are less expensive than solid state or dry sensing membranes and still offer a high degree of accuracy and responsiveness. Electrodes measure 12 mm diameter x 145 mm length and…

  • Thomas Brand Fluoride Ion Electrodes

    Thomas®

    …reference electrode can be used with more than one type half-cell ISE, saving some cost. Electrodes measure 12 mm diameter x 145 mm length and are equipped with a one meter cable and BNC type connector. connectION Technology Direct concentration readout in ppm and pX No Ion

Compare Tool

Select up to 3 products

Please Log In