Ion Selective Electrode Orion

Compare Tool

Select up to 3 products

Ion Selective Electrode Orion
1 - 32 of 45
Sort
View
Show
  • Chloride Ion Electrode & Accessories

    Thermo Scientific Orion

    4210N68 Requires Thomas number 4215F60 reference electrode. Includes 760 mm lead. Uses Orion 900002 fill solution, order as 4215F70. Accessories Chloride Standard, 0.1000 ±0.0005M Chloride Standard, 100.0 ±0.5 ppm Ionic Adjustment Solution, Sodium Nitrate…

  • Fluoride Electrode and Reagent Kits

    Thermo Scientific Orion

    …of dental fluorosis. Thermo Scientific Orion offers Orion Fluoride ISE and Reagent Kits which enable you to easily comply with both standards. Fluoride Electrode and Reagent Kit Components (C838K34) 9609BNWP Combination Fluoride Electrode with Sure-Flow Reference 940907 100 ppm…

  • Calcium Ion Electrode

    Thermo Scientific Orion

    …Includes 60 mL of refill solution. Uses easily replaceable 4210B03 plastic membrane module. 4210B13 Highly selective for calcium over other divalent cations Polymer-membrane electrode measures calcium in aqueous solutions from 40,100 down to 0.02 ppm as calcium over optimal temperature range…

  • Orion Carbon Dioxide Buffer 475 ml

    Thermo Scientific Orion

    Ionic strength adjustor for Carbon Dioxide Electrode. Used for analysis with ion selective electrodes 475mL bottle

  • Orion Ion Selective Electrodes (ISE)

    Thermo Scientific Orion

    Measurements using an ion selective electrode (ISE) are applicable in virtually every laboratory. ISEs can be used to measure ion concentrations in water, food, pharmaceuticals and biological samples. Ion selective electrodes can be used as endpoint indicators or to perform direct measurement and…

  • Potassium Ion Electrode

    Thermo Scientific Orion

    …Combination ISE Optimal temperature range 0 to 40° C Polymer membrane electrode measures potassium in aqueous solutions from 39,000 to 0.04 ppm. Includes easily replaced cat no. 971901 plastic membrane electrode modules and 60 mL of refill solution (900065). Reorder as 0732N10.

  • Electrode Body Handle, Waterproof

    Thermo Scientific Orion

    Thermo Orion IonPlus Handle with BNC Waterproof Connector For Ion+ ISE combination plastic membrane electrodes Accessories for solid state and plastic membrane ion selective electrodes Electrodes handles are used with plastic membrane combination or half cell electrodes Polishing strips…

  • Orion Polishing Strips

    Thermo Scientific Orion

    Polishing Strips for Solid State Ion Selective Electrodes. Helps restore the performance of solid state, half cell, or combination ion selective electrodes Pack of 24

  • Nitrate Ion Electrode

    Thermo Scientific Orion

    …filling solution. Nitrate Standard: 0.1000 ±0.0005 Nitrate Interference Suppressor Solution Filling Solutions:  For 4210S10 Combination Electrode use 4210S03  For 4210S11 and S12 Half Cell Electrodes use 4210S40  For 4215F60 Half Cell Reference Electrode use 4215F70

  • Fluoride Ion Electrode

    Thermo Scientific Orion

    …fluoride ion activity in concentrations from saturated to 10 -6 M (0.02 ppm) Method approved by ASTM for water, drinking water, wastewater and seawater brines and it is approved by EPA, Standard Methods and AOAC for feeds Range saturated to 0.02 ppm Requires 4215F10 reference electrode. Uses…

  • High Performance Ammonia Electrode

    Thermo Scientific Orion

    …membrane on the electrode. The ammonia electrode has a waterproof BNC connector that can be used with any meter that has a BNC input and ensures a waterproof and secure connection when used with the Orion Star Series meters. Easy electrode maintenance with a translucent electrode body with fill…

  • Ammonia Ion Electrode Accessories

    Thermo Scientific Orion

    …with threads to mount membrane. Nitrate Test Kit Permits use of Ammonia Electrodes to measure nitrate Kit solutions are used to make sample basic and then to convert nitrate to ammonia for measurement. Ions such as chloride, which normally interfere, have no effect on the measurement.…

  • Sodium Ion Electrode

    Thermo Scientific Orion

    ROSS, Half Cell ISE For determination of Na+ ion activity in concentrations from saturated to 10 -6 M (saturated to 0.02 ppm) Model 4210E63 ROSS electrode requires Thomas number 4153Q87 or 0732K95 reference electrode. Uses Orion 900004 fill solution, order as 4153F22. Accessories: Sodium…

  • Orion Reference Electrode Fill Solution, Na, 5 X 50 ml

    Thermo Scientific Orion

    …of your ion selective electrodes with Thermo Scientific™ Orion™ ISE Filling Solutions. These solutions are specially formulated to work with the recommended ion selective electrodes and prevent electrode interferences from filling solution. Ion Selective Electrode Filling…

  • Orion Cyanide Electrode w / BNC

    Thermo Scientific Orion

  • Orion Cupric Electrode w / BNC

    Thermo Scientific Orion

  • Orion Potassium Electrode w / BNC

    Thermo Scientific Orion

  • Orion Bromide Electrode w / BNC

    Thermo Scientific Orion

  • Orion Iodide Electrode w / BNC

    Thermo Scientific Orion

  • Orion™ Lead Electrode

    Thermo Scientific Orion

    The Thermo Scientific Orion 9482BN Half-Cell Lead Electrode measures lead ions in aqueous solutions quickly, simply, accurately, and economically. Free-flowing Sure-Flow™ junction assures stable, drift-free potentials When conventional electrode junctions clog, the Sure-Flow™…

  • Orion CO2 Internal Fill Solution

    Thermo Scientific Orion

    …the performance and extend the life of your ion selective electrodes with Thermo Scientific™ Orion™ ISE Filling Solutions. These solutions are specially formulated to work with the recommended ion selective electrodes and prevent electrode interferences from filling solution. …

  • Orion Potassium Sensing Module

    Thermo Scientific Orion

    Replacement Module for Potassium Sure-Flow Combination Electrode (9719BNWP). Plastic membrane half-cell sensing module

  • High Performance Ammonia Electrode and Reagent Kit

    Thermo Scientific Orion

    …with each providing varying standards that must be strictly followed. Orion Ammonia Electrode and Reagent Kits make it easy and economical to measure ammonia levels in wastewater during and after treatment. The Orion High Performance Ammonia ISE, which is part of this kit, offers a fast,…

  • Standard Ammonia Electrode and Reagent Kit

    Thermo Scientific Orion

    …Ammonia Electrode Filling Solution, 60mL  951207 100 ppm Ammonia as Nitrogen Standard, 475mL  951007 1000 ppm Ammonia as Nitrogen Standard, 475mL  951204 Loose membranes for Standard electrodes, Box of 20 951211 pH adjusting ISA, for samples with metalic ions, 475mL …

  • Orion Potassium Isa, 475 ml

    Thermo Scientific Orion

    Orion™ ISE Ionic Strength Adjustors (ISA). Used for analysis with ion selective electrodes, ionic strength adjustor is added to all samples and standards to create a uniform background ionic strength, which provides more reproducible measurements ISA for Potassium Electrode 475 mL…

  • Orion Lead Standard 475 ml

    Thermo Scientific Orion

    Sulfate Standard for Lead ISE. For use with Ion selective electrodes from ammonia to water hardness 0.1M concentration 475 mL

  • Orion Nitrate Isa, 475 ml

    Thermo Scientific Orion

    Adjusts the ionic strength of samples and standards to similar levels so an electrode can be calibrated Reduces the effect of interfering ions to minimize distortion of electrode readings For use with particular ion selective electrodes(sold separately) 10 ppm concentration 475 mL bottle

  • Orion Iodide Standard, 475 ml

    Thermo Scientific Orion

    Iodide Standard for use with Iodide Ion selective electrodes. 0.1M concentration 475 mL bottle

  • Orion 1000 ppm Na Standard, 475 ml

    Thermo Scientific Orion

    Sodium standard for use with Ion selective electrodes from ammonia to water hardness. 1000 ppm concentration 475 mL bottle

  • Orion 10 ppm Sodium Standard, 475 ml

    Thermo Scientific Orion

    Sodium standard for use with Sodium Ion selective electrodes. 475 mL bottle 10 ppm concentration

  • Orion Chloride Act Standard, 475 ml

    Thermo Scientific Orion

    Chloride standard for use with Chloride Ion selective electrodes. 1000 ppm concentration 475 mL bottle

  • Orion Carbon Dioxide Standard, 475 ml

    Thermo Scientific Orion

    Carbon Dioxide standard for use with Ion selective electrodes. 0.1 M concentration 475 mL bottle

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.