Injection Septum
-
Adapter, Injection Port, Michel-Miller
Ace Glass…PTFE septum injector. Allows direct, on-column injection to the center of the filter disc at top of column without stopping the solvent flow through the 1/4"-28 female side thread (with or without helicoil). Locknut design provides leaktight seal without o-rings. You can order the 5/16"-28 septum…
-
…Microseal septum include elimination of septum coring; longer life; and consistent, low needle-insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs in the injection port liner.…
-
Thermogreen® LB-2 Septa
MilliporeSigmaSeptum is a very important component of syringe injection system. They are usually fabricated from elastomeric, self-sealing materials such as silicone rubber, neoprene or fluoroelastomers. It is suitable to conveniently introducing the sample without causing the system to leak. Improper septa…
-
Premium HT quality GC injection port septa
MACHEREY-NAGEL…critical analyzes Longer lasting than BTO septa Combines longevity and low bleeding pattern Marathon Septa with extremely long life Longest lasting septa - also for use with autosamplers Up to 400 injections per septum Also ideal for manual standing injections for GC and GC-MS
-
Standard quality GC injection port septa
MACHEREY-NAGELGC injection port septa Standard quality Septum grade: Standard septa (ST) Material: beige silicone Thickness: 4 mm Hardness: 60° shore A Septum grade: High temperature septa (HT) Material: red non-bleeding silicone Thickness: 3 mm Hardness: 60° shore A …
-
Needle guide allows easy penetration and prevents septum coring Manual injection septum nut allows use of 26-gauge needles for on-column injections Made of high-quality stainless steel
-
…thousands of injections Eliminates septum coring and crumbling Reliable performance during extended runs O-ring detail seals needle during injection Duckbill seals more tightly at higher pressures Low insertion force for easy manual injections Reduced septum bleed and ghost…
-
Septa Pick
Chromatography Research SuppliesFor removing small pieces of septa lodged in the threads and corners of the septum cap or injection port and other small cleaning jobs.
-
Septa
Agilent Technologies…the injection side that guides the syringe needle to the same point with every injection. Center point guides the needle for easy penetration and less coring. Long-Life Septa are the preferred septum for autosamplers and are ideal for overnight runs. You can make up to 400 injections per septum…
-
…Microseal septum include elimination of septum coring, longer life, and consistently low needle-insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs in the injection port liner.…
-
…Microseal septum include elimination of septum coring, longer life, and consistent low needle insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs in the injection port liner.…
-
…types of tubing and various configurations that can integrate needle-free valves including the SmartSite™ valve or VersaSafe™ split septum injection ports. Gravity set check valve flow regulator slide clamp(s) 2 NAC-y needle-free valve(s) 7", 54" from spin male luer lock.…
-
The Advanced Green septum was created to combine significantlylonger injection life, low bleed and low injection port adhesion.The result is a general use green septum you can use for all yourcritical analyses. Advance Green septa are packaged in a plasticdial pack of 10 septa.
-
Aluminum Seals with PTFE-Faced Silicone Septa
DWK Life Sciences (Kimble)Medium durometer PTFE / silicone septum Allows for good resealability, core resistance, multiple injections and easy penetration
-
…elimination of septum coring, long lifetime, and consistently low needle-insertion force. The Microseal septum incorporates two separate sealing mechanisms; these sliding seals prevent septum coring and the associated accumulation of septum crumbs in the injection port liner. Installation…
-
Head, Hickman Still
Ace Glass…threaded to allow a O-RING-CAP-SEAL connection with mating male joint and inner joint at bottom. Supplied with cap, O-Ring and septum. Available with ex-ternally threaded outer side port off resevoir, both side port and top joint supplied with cap and septum for syringe injection or retrieval.
-
8-425 Screw Thread Caps with Inserted Septa
National Scientific…caps and septa are convenient and minimize contamination from handling Phenolic caps can be autoclaved Kim-Lok™ cap/septum assemblies feature a molded centering ring to eliminate septum movement during injection Storage cap has a solid top and pre-inserted PTFE disk liner
-
…Microseal septum include elimination of septum coring; longer life; and consistent, low needle-insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs in the injection port liner.…
-
Septa, Long Life GC Autosampler
HamiltonLong injection life, pre-pierced for minimal coring. Maximum temperature 400°C. Long injection life septum typically achieves 400 injections without failure, when used with a rounded-tip (Agilent-style) needle and autosampler or needle guide. Ideal for standard manual-injection GC and GC/MS. 3 mm…
-
Vials, screw top
MilliporeSigmaVials (volume 7 mL, clear glass vial, O.D. x H 17 mm x 60 mm, tan PTFE/silicone septum) are suitable basically to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials. Caps are made from phenolic…
-
Marathon Septa
Chromatography Research Supplies…GC Septa for autosampler use Outstanding lifetime Very low bleed Maximum temperature of 350°C Septum typically achieves 400 injections without failure when used with HP-style needles and autosampler needle guide. Soft, 45 Durometer, septa are easy on autosampler…
-
…plunger design minimizes bending and seizing, and the cone tip needle point style has been developed specifically to withstand multiple fast septum injections. Select from a wide range of fixed needle and removable needle options. PTFE tipped replaceable plunger versions are available for use…
-
…plunger design minimizes bending and seizing, and the cone tip needle point style has been developed specifically to withstand multiple fast septum injections. Select from a wide range of fixed needle and removable needle options. PTFE tipped replaceable plunger versions are available for use…
-
…liner. Why replace the septum? The septum maintains a leak-tight seal that excludes air from the inlet. Frequent replacement prevents fragmentation and leaks. Multiple injections and continuous exposure to hot injection port surfaces will decompose the septum and can create particles, which…
-
Gas Sampling Bulbs, 250cc
SP Bel-Art…recommended pressure is 15 psi 1207Y48 has 4mm straight bore stopcock on one end and silicone rubber septum mounted in screw fitting on the other end. Septum can withstand several injections. 6 septa included. Overall length 29cm (11-15/16") 0211F02 has 4mm straight bore stopcock on each…
-
Molded Thermogreen® LB-2 Septa
MilliporeSigma…puncture the same location every injection, resulting in two benefits: •Minimal coring leading to long life •Less septum fragments that contaminate the inlet linerTheir high puncture tolerance makes these septa ideal for use with autosampler injections, manual injections, and/or SPME applications.
-
Thermogreen® LB-2 Septa
MilliporeSigmaSeptum is a very important component of syringe injection system. They are usually fabricated from elastomeric, self-sealing materials such as silicone rubber, neoprene or fluoroelastomers. It is suitable to conveniently introducing the sample without causing the system to leak. Improper septa…
-
Caps
TriForest…culture. Septum Cap Serves as closure for flasks and media bottles. This cap comes in standard blue polypropelene with gray butyl rubber. Ideal for injectibles, especially pathogenic media. DuoSeptum Cap This cap is an ingenious combination of our TriForest septum Cap and vented…
-
Chromatography Syringes
Hamilton…allowing 6000 psig maximum injection pressures. These hubs also allow the attachment of a spacer for repeatable injection depths. Point style 2 needles are beveled, non-coring needle points for septum penetration. Point style 3 needles are recommended for HPLC injection valves and for sample…
-
The inlet seal at the base of the GC injection port contacts the sample and must be changed frequently to prevent adsorption of active compounds. In addition, septum fragments and sample residue accumulate on the disk surface, requiring disk replacement. Siltek treatment provides inertness…
-
Vials, screw top with phenolic open-top cap, pre-assembled
MilliporeSigmaVials are used basically to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials. Screw top glass vials are used on many autosamplers with a standard opening of 4.6 mm. Amber glass prevents the…
-
Inlet Liner, Direct (SPME) Type, Straight Design (unpacked)
MilliporeSigma…capillary injection ports. Fits Agilent (5890, 6890, and 7890) Fits Finnigan (9001GCQ) Fits Varian (CP-1177 Injector) The liner is the second most important part of the inlet. It is the centrepiece of the inlet system, basically a glass tube between the septum and the column,…
