  • The glass indicating trap clearly shows when the filter needs to be replaced with the use of color changes. The packing material is a silica-based environmentally friendly substitute for cobalt dioxide (blue) in the moisture indicator. Available as a kit with the necessary 1/8" brass connectors, and…

  • Helium-specific Click-On in-line Super Clean gas trap and kits are designed specifically for purification of helium in GC-MS systems.

  • Click-On Inline Super-Clean Traps are inline traps designed with Click-On adaptor connectors which allows inline cartridges to be exchanged without introducing oxygen. Spring loaded check valves seal when a filter is removed and open only when a new filter has been locked in. There is no need for…

  • Hydrocarbon Trap

    PerkinElmer

    New Hydrocarbon Trap - great for LCMS nitrogen units and GC units with 1.5 times the capacity of our current N9301192 High Capacity Hydrocarbon Trap - N9301192 Contains 750cc of preconditioned activated charcoal. Stainless Steel bdy. 1/4" brass compression fittings with ferrules for…

  • Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen Reduces water to less than 15 ppb Maximum operating pressure: 250 psi (1,724 kPa) Maximum flow: 1.25 L/min

  • Packed with an extremely high surface area, baked coconut shell–based activated carbon Purged with ultra-high-purity helium; ready to use with any carrier gas including hydrogen Reduces organics to 0.1 ppm (assuming 100 ppm input) Maximum operating pressure: 250 psi (1,724 kPa)

  • …included. Your elemental analyzer uses several gases. High purity oxygen (99.995 mole percent minimum) is required for sample combustion. Prepurified helium (99.995 mole percent minimum is recommended) or argon carry the products of combustion through the system. During oxygen analysis, pyrolysis of…

  • …This avoids the costly replacement observed with other broad-spectrum traps that have exhausted their capacity for one contaminant, but still have capacity for other contaminants. This trap will easily purify 99.997% purity helium to a cumulative level of 100 ppb (hydrocarbons + moisture + oxygen +…

  • Oxygen/Moisture Traps

    Agilent Technologies

    …adsorbents team up to give you two functionalities in the same trap Optimized for maximum surface area and capacity Leak-free, one-piece design (tested to 2000 psi) Bed material treated with ultra-high purity helium Filter design: prevents channeling, promotes efficient scrubbing…

  • …99.9999% pure gas (maximum flow of 8 L/min). Triple gas trap is ideal for purifying carrier gas. Helium-specific triple gas trap is made for GC-MS—ready to use within 15 minutes of installation. Hydrocarbon trap removes hydrocarbon contamination from carrier gas to help eliminate…

  • This trap contains oxygen, moisture and hydrocarbons adsorbents in one trap and is packed and purged under helium. The glass indicating trap clearly shows when the filter needs to be replaced with the use of color changes. The packing material is a silica-based environmentally friendly substitute…

  • Capillary Grade Hydrocarbon Traps

    Agilent Technologies

    Extremely high surface area, coconut shell-based, activated carbon 100 cc of filtering media Purged with ultra-high purity helium Refillable

  • …supply or system operation. Spring-loaded check valves seal when a filter is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process.

  • Big Universal Traps

    Agilent Technologies

    …pressure is 500 psi. Big Universal Traps are more economical than other purifiers. They cost only slightly more than competitive products, but offer nearly three times the capacity. Big Universal Traps are ideal for any GC or GC/MS application where helium is employed and assurance of purity is…

  • …is removed and open only when a new filter has been locked in place. There is no longer a need for loosening and tightening fittings every time a trap is changed and your system will not become contaminated during the process. Carrier Gas Purity Carrier gas should contain less than 1ppm of oxygen,…

  • …Indicating Moisture Traps are designed to remove water, oil, and organics from gases employed in, but not limited to, gas chromatography. Refillable moisture traps are constructed from Lexan brand polycarbonate tubing. Lightweight, chemically resistant and of superior strength when compared to traps

  • Specifically designed for purification of helium in GC-MS systems Traps are packed and conditioned using helium Uses standard single-position base plate

  • Available in three different sizes Mixed packing bed prevents improper installation Easily refillable Tested to 150 psi (helium) Both inlet and outlet connectors are equipped with stainless steel frits to prevent particulates from entering the gas stream. Indicating 4Å is…

  • Sampling Screen

    PerkinElmer

    …hydrocarbon impurities (50 ppm or less) from inert gases, nitrogen and hydrogen at room temperature to low ppb range, Capacity of 67 g of hydrocarbons C5 and heavier, 10 µ stainless steel porous frits protect gas stream from particulates, and Individually helium leak tested. Shipped lled wth helium.

  • …ppm) purity, and correspondingly longer for purer gases. Replace separate oxygen, moisture, and hydrocarbon traps with one multiple-bed purifier, specific for purifying helium, hydrogen, nitrogen, or air Reduce gas impurities from ppm to low ppb levels Decrease baseline noise and…

  • … One 2 m oxygen column (P/N N2420212) One quartz insert (P/N N2411401) One 454 g. bottle of Copper Plus Wire Form (P/N 02401362) One scrubber trap assembly (P/N N2410189) One acid gas scrubber tube (P/N N2411359) One 100 g. bottle of Colorcarb (P/N 02400115) One 454 g. bottle of Magnesium…