  • …fiberglass-reinforced serpentine-wound multi-stranded heating element Power density: 6.0 watts/in 2 (0.009 watts/mm 2 ) Suitable for electrically conductive surfaces Compact, time percentage controller built-in 6 feet (2m) long power cord with options 120VAC: standard 2-prong plug…

  • … Includes adjustable thermostat control Useful for a wide range of applications:  Process temperature control De-icing Supplemental heat Exceptional heater flexibility, durability, and uniformity…

  • … Includes adjustable thermostat control Useful for a wide range of applications:  Process temperature control De-icing Supplemental heat Exceptional heater flexibility, durability, and uniformity…

  • Product Highlights Built-in adjustable thermostat control Useful for a wide range of applications: Process temperature control, De-icing, Supplemental heat Exceptional heater flexibility, durability, and uniformity Rapid heat-up and thermal response Specifications …

  • Product Highlights Built-in adjustable thermostat control Useful for a wide range of applications: Process temperature control, De-icing, Supplemental heat Exceptional heater flexibility, durability, and uniformity Rapid heat-up and thermal response Specifications …

  • …time-on/time-off stepless input control, 5% thru 62% plus full-on Built-in cycle and power-on lights One standard single duplex outlet at rear of housing Control compensates for line voltage fluctuations and ambient temperature changes. Control comes complete with five foot, 3-wire…

  • 1-Way Heating Controllers

    Electrothermal (Cole-Parmer)

    …designed to control the heating of resistive loads for bench top operation. The heating controllers deliver different levels of power according to your requirements and are suitable for EM series Electromantles, the Electric Bunsen and Heating Cords and Tapes. Each heating controller has 2 neon…

  • …positive break when turned off. Pilot light is connected across the output side of the control and indicates power to the load. Features simple dial setting which, with the desired temperature determined on the initial run, controls repeat operation. Dimensions: 63 x 108 x 51 mm H; 120 V, 50/60 Hz.

  • …high-moisture areas and helps to make the tapes resistant to most laboratory environmental conditions Electrical connections: in-locking plug on one end of tape. Separable cord with 2-blade plug. Maximum temperature 480°F. For 120 V controller see Thomas number 5916A10; for 230 V see…

  • Provides precise manual control of heating mantles, tapes, cords and other resistive loads Adjustable output range from 3-100% of rated voltage Mount on lattice work or bench top Model 5915A01 will accommodate non-conductive loads to 1200 watts; model 5915A05 to 2400 watts. Electrical…

  • …response. Maximum exposure temperatures up to 482°F (250°C) Perfect for a wide range of applications including heating laboratory apparatus, gas tubing, temporary heat, valves, and more! Exceptional flexibility and durability Wide range of sizes Includes 9" (230mm) long high…

  • Controls two separate circuits independently Provides precise manual control of heating mantles, tapes, cords and other resistive loads Adjustable output range from 3-100% of rated voltage Use on bench top or mount to lattice work using clamp provided on back panel Will…

  • Use with heating mantles, tapes, cords, small ovens and other resistive heating loads Digital dual output display for set point and process temperature indication Automatic tuning for accuracy with minimum overshoot Auto cold junction compensation and thermocouple break protection …

  • Heating tapes must be operated through a power control. In both permanent and temporary applications, this tape heats odd lengths of glass tubes and metal pipes. Ribbon-type heating elements running lengthwise in the tape are encased in durable glass braid and are impregnated and covered with

  • …attached cord with 2 blade plug. Single end termination Power ratings are for tapes not covered by insulation when installed. If covered, temperature should be monitored and controlled to avoid exceeding 480 degree F limit. Heating tapes must be operated through a power control.

  • …Maximum exposure temperatures up to 900°F (482°C) Perfect for a wide range of applications including heating laboratory apparatus, gas tubing, temporary heat, valves, and more! Exceptional flexibility and durability Wide range of sizes Suitable for electrically conductive…

  • Provides automatic, time-proportioning control of temperature for loads of up to 1,200 watts Temperature range 0-500°C (0-1,000°F) Used with heating mantles, tapes, cords, small ovens and other resistive heating loads Controller has a calibrated set-point dial in °C and…

  • Tape

    Glas-Col

    In both permanent and temporary applications, this tape heats odd lengths of glass tubes and metal pipes. Ribbon-type heating elements running lengthwise in the tape are encased in durable glass braid and are impregnated and covered with tough silicone rubber, which insulates stranded terminal leads…

  • Tape

    Glas-Col

    tapes must be operated through a power control.  In both permanent and temporary applications, this tape heats odd lengths of glass tubes and metal pipes. Ribbon-type heating elements running lengthwise in the tape are encased in durable glass braid and are impregnated and covered with

  • Tape

    Glas-Col

    tapes must be operated through a power control.  In both permanent and temporary applications, this tape heats odd lengths of glass tubes and metal pipes. Ribbon-type heating elements running lengthwise in the tape are encased in durable glass braid and are impregnated and covered with

  • …to your choice of temperature control Includes high-temperature tie-downs for easy installation Wide range of sizes Specifications Highly flexible and durable multi-stranded dual heating element provides even heat across the tape Reinforced with high temperature Samox®…

  • …Polyimide film wrapped fiberglass knitted and braided heating element construction Power density: 4.3 watts/in 2 (0.007 watts/mm 2 ) Suitable for electrical conductive surfaces 24" (610mm) power leads with 3-wire bare wire connection 120 or 240VAC Temperature controller required

  • …up to 900°F (482°C) Fiberglass knitted and braided construction Power density: 8.6 watts/in 2 (0.013 watts/mm 2 ) 24" (610mm) power leads with: 120VAC: Separable standard 2-prong power plug (NEMA 1-15) 240VAC: Bare wire connection Temperature controller required

  • … Specifications Built-in controlling thermostat set at 60°F (16 ° C) Maximum exposure temperature: 450 ° F (232 ° C) Silicone rubber extruded outer sheath Moisture and chemical resistant Patented grounded heating element meets NEC 427.23 Power density:…

  • …of heating mantle controllers feature solid-state proportional voltage power control in a compact benchtop design. Controllers provide accurate manual control of heating mantles, tapes and all other resistive loads with an adjustable output range from 5 to 100% of the rated voltage. Controller is…

  • Our controllers feature solid-state proportional voltage power control in a compact benchtop design. Controllers provide accurate manual control of heating mantles, tapes and all other resistive loads with an adjustable output range from 5 to 100% of the rated voltage. All units are supplied with a…

  • …(760°C) High temperature Samox® knitted and braided construction Power density: 13.1 watts/in 2 (0.020 watts/mm 2 ) 24" (610mm) power leads with: 120VAC: Separable standard 2-prong power plug (NEMA 1-15) 240VAC: Bare wire connection Temperature controller required

  • …and braided heating element construction Moisture and chemical resistant Power density: 4.3 watts/in 2 (0.007 watts/mm 2 ) 24" (610mm) power leads with: 120VAC: Separable standard 2-prong power plug (NEMA 1-15) 240VAC: Bare wire connection Temperature controller required

  • …Maximum exposure temperatures up to 900°F (482°C) Perfect for a wide range of applications including heating laboratory apparatus, gas tubing, temporary heat, valves, and more! Exceptional flexibility and durability Wide range of sizes Suitable for electrically conductive…

  • …Maximum exposure temperatures up to 900°F (482°C) Perfect for a wide range of applications including heating laboratory apparatus, gas tubing, temporary heat, valves, and more! Exceptional flexibility and durability Wide range of sizes Suitable for electrically conductive…

  • …lamp, 3-wire receptacle (U.S. plug) on a 12 in. cord, and a 4 ft, 3-wire power cord with U.S. plug. Used to control THERMOWELL heating mantles or other resistive heating circuits (hot plates, heat tapes, water baths, etc.). Available in solid-state or proportional on/off models. All models…

  • …easy with single end termination. Electrical: 2 wire locking plug on one end of cord All heating cords have separable extension cord with 2 blade plug For temperature regulation always operate through controls. Because most laboratory uses are temporary, manual controls such as…