  • Ramptrol Heating Mantle Controller

    Glas-Col

    …microprocessor-based ramping control Microprocessor based PID control Ramp-rate or time-based programming profiles 24 Step program capability Program looping Guaranteed soak (dwell) deviation Auto tuning function allows automatic setting of control parameters with a…

  • Electromantle® EM Series Heating Mantles With Controller

    Electrothermal (Bibby Scientific US)

    Unique Electrothermal replaceable heating element/cartridge Heating mantle and controller in one unit Polypropylene housing The EM Series Electromantle incorporates the proven electrothermal coiled, flexible heating element in special insulation and features a “power…

  • Heating Mantles

    Glas-Col

    …order. In self-standing metal case, Model TM (5910C10 to C45) Glass cloth mantle, which is suspended in cylindrical aluminum housing; heavily insulated against heat loss Heating element is distributed over bottom and sides. Housing is grounded to third wire of line cord,…

  • Temp 9000 Standard Benchtop Temperature Controllers

    Oakton

    Outlet receptacle allows for direct plug-in of heating devices such as hot plates, heat tapes, or mantles. These temperature controllers can be used for a wide variety of applications including pilot process plants, R & D labs, or for OEM requirements. Rear panel output receptacle for direct…

  • HM Upper Hemispherical Heating Mantles

    BriskHeat

    …of flask Excellent alternative to other heating methods like a bunsen burner Opening holds 1, 2, or 3 neck flasks on ring stand Specifications Fiberglass cloth outer shell Uniform, low-watt density knitted and braided heating element. Temperatures up to 900°F (482 °…

  • Traceable® Temperature Controller

    Thomas®

    …On/Off settings Controllers turn any piece of equipment on or off when the temperature rises above a “high” set point or falls below a “low” set point. Automatic switchings allow it to control heating elements, cooling blocks, hot plates, heating mantles, cooling systems or…

  • Minitrol Heating Mantle Controller

    Glas-Col

    Manually adjustable; has a percentage-timer design and no sensing element Regulates mantles, tapes and cords, as well as small furnaces, ovens, hot plates, dies and other applications requiring stepless control Can be used on any non-inductive loads to its rated capacity of 1,440 watts …

  • Electrothermal EMA Stirring Heating Mantles

    Electrothermal (Bibby Scientific US)

    …achieved by placing the correct size stir bar into the flask, turning the stir control to the minimum speed and ramping up slowly. If the magnetic coupling to the stir bar is lost for any reason, the stir speed control should be reduced slightly and the auto-recapture switch can be activated. …

  • Powrtrol Heating Mantle Controller

    Glas-Col

    Provides precise manual control of heating mantles, tapes, cords and other resistive loads Adjustable output range from 3-100% of rated voltage Mount on lattice work or bench top Model 5915A01 will accommodate non-conductive loads to 1200 watts; model 5915A05 to 2400 watts. Electrical…

  • Temperature Controllers

    Glas-Col

    For use with heating mantles, tapes, ovens, water baths or other processes requiring accurate temperature control Feature a 1/32 DIN format with 1 or 2 load receptacles Easy set-up and simple input commands make this controller very user-friendly Controllers use one thermocouple to…

  • Heating Mantle RB Flask 50ml

    Glas-Col

    Heating mantles are preferred to Bunsen burners or hot plates for organic liquids. They provide even heating (no hot spots) and maximum surface coverage for better temperature uniformity. The Series TM spherical flask mantle covers only the flask's bottom half, letting you see its full contents.…

  • Powrtwin Heating Mantle Controller

    Glas-Col

    Controls two separate circuits independently Provides precise manual control of heating mantles, tapes, cords and other resistive loads Adjustable output range from 3-100% of rated voltage Use on bench top or mount to lattice work using clamp provided on back panel Will…

  • Limitrol Heating Mantle Controller

    Glas-Col

    Provides a safety backup for lab heating processes Compact, 1/16 DIN unit Allows for over-temperature limiting Terminates primary control when temperature exceeds set limit Model 5916A30 will accommodate a non-conductive load to 1200 watts; Model 5916A35 to 2400 watts.…

  • HM Spherical Heating Mantles

    BriskHeat

    …halves together 120VAC model includes 3” (76mm) lead wire with NEMA L1-15R connector and a 4-foot (1.2m) power adaptor cord with NEMA 1-15 plug. 240VAC model includes 3” (76mm) lead wire with no plug Temperature controller is required for these products

  • 1-Way Heating Controllers

    Electrothermal (Bibby Scientific US)

    …They all have a regulator control knob which can be turned clockwise to increase power. As the knob is turned, the heating controller's amber neon light will pulsate to show that power is being supplied to the equipment being controlled, e.g. mantles, heating tape or cord. The pulse frequency…

  • CMU Controlled Electromantles™

    Electrothermal (Bibby Scientific US)

    CMU Controlled Electromantles CMU metal-cased Electromantles are used in chemistry to heat liquids in round bottom flasks. They are ideal for busy laboratories with multiple users as they are very safe to use, the metal case being designed to remain "cool-to-the-touch" when in…

  • EMC-4 StirControl II Speed Controller for StirMantles

    Glas-Col

    For use with Thomas 5912L10 series Synchronizes the rotation of the magnetic fields with its solid-state electronic controls Fine control of stirring speed; there is almost no variation; no speed increase in warming or slowdown in cooling Can be reproducibly set to any given speed; range 50 rpm…

  • Resin Fabric Mantles

    Glas-Col

    This mantle's even heat distribution prevents scorching of clear resinous materials. It's one-circuit heat input simplifies temperature control. Resin flask mantles, as well as most other Series O mantles, are available modified to accept vessel drains or other tubulations.

  • CMUA Electromantles™ for Heating and Stirring

    Electrothermal (Bibby Scientific US)

    …is simply achieved by placing the correct style and sized magnetic stir bar into the flask, selecting the minimum speed on the stirring dial control and then ramping up slowly to the required speed. The correct style and size of stir bar is determined according to the flask volume and the viscosity…

  • Digitrol II Heating Mantle Controller

    Glas-Col

    Use with heating mantles, tapes, cords, small ovens and other resistive heating loads Digital dual output display for set point and process temperature indication Automatic tuning for accuracy with minimum overshoot Auto cold junction compensation and thermocouple break protection …

  • Heat Mantle w / Control CSA250ml

    Glas-Col

  • Premier Heating Mantle

    Glas-Col

    …found on other heating mantles Chemical-resistant cabinet Housing remains cool to the touch during operation UL fire-rated plastic enclosure Spills are channeled away from heating element Built-in proportional power controller maintains precise temperature control. Heating element is easily…

  • HM Table Top Heating Mantles

    BriskHeat

    … Self-supporting: can be placed directly on counter top Easy viewing of flask contents Stackable for easy storage Includes 6-foot (1.8m) power cord with either a NEMA 1-15 (for 120VAC) or NEMA 6-15 (for 240VAC) plug Temperature controller is required for this product

  • Electrothermal CMUT Multiple Volume Heating Mantles

    Electrothermal (Bibby Scientific US)

    …coiled heating elements absorb shock, minimising the risk of flask breakage Heating element is attached to a rigid thermal insulating cartridge to ensure maximum heat transfer and support Added safety features such as a grounded earth stainless steel screen covering the heating element…

  • Mantle Minder II Heating Mantle Controller

    Glas-Col

    Provides automatic, time-proportioning control of temperature for loads of up to 1,200 watts Temperature range 0-500°C (0-1,000°F) Used with heating mantles, tapes, cords, small ovens and other resistive heating loads Controller has a calibrated set-point dial in °C and…

  • Heat Mantle w / Control CSA500ml

    Glas-Col

  • Heat Mantle w / Control CSA5000ml

    Glas-Col

  • Heat Mantle w / Control CSA1000ml

    Glas-Col

  • Heat Mantle w / Control CSA2000ml

    Glas-Col

  • Heat Mantle w / Control CSA300ml

    Glas-Col

  • Heat Mantle w / Control 3000ml

    Glas-Col

  • Mantle Accessory

    Glas-Col

    Heating mantles must be operated through a power control. Heating mantles are preferred to Bunsen burners or hot plates for organic liquids. They provide even heating (no hot spots) and maximum surface coverage for better temperature uniformity. The Series TM mantles for paint cans in…