Grinding Bead

Compare Tool

Select up to 3 products

Grinding Bead
1 - 32 of 91
Sort
View
Show
  • …Biology Grade Grinding Beads are treated to inactivate contaminating enzymes and have been tested accordingly. Low Binding Grinding Beads are coated to reduce non-specific binding of nucleic acids and proteins and are used for lysing dilute samples of cells. Acid Washed Grinding Beads are treated to…

  • Hard tissue grinding MK28-R 2.8mm metal beads - 2mL pre filled Reinforced tubes ; Reinforced Lysing kit for Precellys - MK28-R Hard tissue kit - 2mL tubes 50 prep. The MK28 matrix is composed of 2.8mm Metal beads recommended for hard tissues such as muscle, skin, spinal cord, bone, teeth, hair but…

  • Hard tissue grinding MK28 - 2.8mm metal beads - 2mL pre filled tubes Lysing kit for Precellys - MK28 Hard tissue kit - 2mL tubes 50 prep. The MK28 matrix is composed of 2.8mm Metal beads recommended for hard tissues such as muscle, skin, spinal cord, bone, teeth, hair but also for plant roots,…

  • Sample grinding GK60

    Bertin Corp

    Sample grinding GK60 - Mix of Garnet beads in 2mL pre filled Reinforced tubes ; Includes 50 preps of garnet flakes 0.7mm and one ceramic (Zirconium Oxide, Ceria stabilized) in 2mL reinforced tubes. GK60 is designed for wet or dry tissue grinding like liver, plants, or dry samples like rice and more.…

  • Soil grinding SK38

    Bertin Corp

    Soil grinding SK38 - Mix of glass and Zirconium oxide beads - 2mL pre filled tubes ; Lysing kit for Precellys - SK38 Soil Kit - 2mL tubes 50 Prep. The SK38 kit is composed of a complex matrix containing 0.1mm glass beads, 1.4mm ceramic (zirconium oxide) beads and a 3mm glass bead. This kit is…

  • Tissue grinding CKMix50-R - Mix of 2.8mm and 5.0mm Zirconium oxide beads - 2mL pre filled Reinforced tubes ; Reinforced Lysing kit for Precellys - CKMix50-R Hard tissue kit -2mL tubes 50 prep. The CKMix50 matrix is composed of a dual ceramic (zirconium oxide) bead type of 2.8mm and 5.0mm in…

  • Chrome steel has a density of 7.9g/cc (used mostly for grinding leaves). Beads are sold in one pound bottles.

  • Tissue grinding CKMix50, 7mL -Mix of 2.8mm and 5.0mm Zirconium oxide beads - 7mL pre filled tubes; Lysing kit for Precellys - CKMix50 Hard Tissue kit - 7mL tubes 50 prep. The CKMix50 matrix is composed of a dual ceramic (zirconium oxide) bead type of 2.8mm and 5.0mm and is recommended for hard…

  • Tissue grinding CKMix50, 15mL - Mix of 2.8.. and 5.0mm Zirconium oxide beads - 15mL pre filled tubes ; Lysing kit for Precellys - CKMix50 Tissue kit - 15mL tubes 25 prep. The CKMix50 matrix is composed of a dual ceramic (zirconium oxide) bead type of 2.8mm and 5.0mm and is recommended for hard…

  • Soil grinding SK38_7mL - Mix of glass and Zirconium oxide beads-7mL pre filled tubes ; Lysing kit for Precellys - SK38 Soil kit - 7mL tubes 50 prep. The SK38 kit is composed of a complex matrix containing 0.1mm glass beads, 1.4mm ceramic (zirconium oxide) beads and a 3mm glass bead. This kit is…

  • Dry hard tissue grinding CK68-R- 6.8 mm ceramic beads - 2mL pre filled Reinforced tubes; Reinforced Lysing kit for Precellys - CK68-R Dry Hard Tissue kit - 2mL tubes 50 prep. The CK68 matrix is composed of 6.8mm ceramic (zirconium oxide) bead recommended for hard tissues such as muscle, skin,…

  • Dry hard tissue grinding CK68, 15mL - 6.8mm ceramic beads -152mL pre filled ; Lysing kit for Precellys - CK68 Dry Hard Tissue kit - 15mL tubes 25 prep. The CK68 matrix is composed of 6.8mmceramic (zirconium oxide) bead recommended for hard tissues such as muscle, bone, teeth, hair but also for…

  • …closing. Applications Dry grinding very tough or hard samples where heat generated can damage plastic tubes Cryogenic dry grinding where severe cold temps (dry ice or LN2) can damage plastic tubes Milling or grinding non-biological samples where plastic contamination…

  • …closing. Applications Dry grinding very tough or hard samples where heat generated can damage plastic tubes Cryogenic dry grinding where severe cold temps (dry ice or LN2) can damage plastic tubes Milling or grinding non-biological samples where plastic contamination…

  • Bead tubes are pre-filled with an optimized amount of lysing matrix. Bead Media: Glass, Metal, Ceramic Compatible with: Bead Ruptor 4, 12 and 24 Certification: RNase & DNase free Soft Tissue Homogenizing Mix Recommended for: soft tissues, brain, liver, kidney, spleen,…

  • …for lysis, grinding or homogenization Faster and more effective than tissue grinders Mix 1, 2 or 3 tubes simultaneously Extremely compact, less than 7" wide Eliminates the cross contamination associated with hand held homogenizers Compatible with these Beads and Prefilled…

  • …nuclease Bead beating is quickly becoming the preferred process used to break up (lyse) samples in order to release the DNA, RNA and proteins contained within cells. Samples are placed in tubes with the appropriate grinding beads and subjected to high energy mixing. The beads impact the…

  • Stainless steel beads have a density of 7.9g/cc. They are used mostly for grinding leaves and seeds. They are made of Type 316 stainless steel - the most corrosion resistant available.

  • …(cryo-grinding). Dry gringing requires using special microvials resistant to breakage. When dry grinding with ceramic or steel beads at room temperature our 'XXTuff' microvials are recommended. Our stainless steel microvials are available for dry grinding with steel beads at cryo-temperatures.

  • …separately for those who wish to fill their own Lysing Matrix Tubes. Use with Empty FastPrep Tubes. Add sample to empty tube, add appropriate Lysing Matrix material and lysing buffer, and apply cap. Process using FastPrep instrument or other bead-beater to lsye, grind or homogenize sample.

  • SuperFastPrep-2™

    MP Biomedicals

    The SuperFastPrep-2™ is an attachment for a rotary tool developed for vigorous cell disruption (bead beating) and allows the researcher/investigator to process samples in the field, at the site of sample collection. It can be used to lyse microbes in soil, sediment, sludge, and fecal samples…

  • …by impaction of tough chitin/protein composites that comprise the exoskeleton of arthropods and crustaceans. Matrix I can also be used for dry grinding fungal spores to isolate RNA and Proteins. Lysing Matrices are critical components of the FastPrep™ Sample Preparation system. MP…

  • …mL cluster-strip tube and cap assemblies. Each tube is pre-filled with garnet matrix and 1 (one) 4 mm glass grinding sphere. Lysing Matrix A is used for all sample types except soil for the subsequent isolation of genomic DNA. This grinding matrix is chemically inert and will not bind nucleic acids.

  • Each impact-resistant 15mL tube contains 2.0 mm diameter Yttria-Stabilized Zirconium Oxide beads. Y2O3 + ZrO2 has high density and has extremely high hardness making this matrix ideal for cracking of very tough cell walls, while it's smooth.

  • Each impact-resistant 15mL tube contains 2.0 mm diameter Yttria-Stabilized Zirconium Oxide beads. Y2O3 + ZrO2 has high density and has extremely high hardness making this matrix ideal for cracking of very tough cell walls, while it's smooth.

  • Each impact-resistant 4.5 mL tube contains 0.5 mm diameter Yttria-Stabilized Zirconium Oxide beads. Y2O3 + ZrO2 has high density and has extremely high hardness making this matrix ideal for cracking of very tough cell walls, while it's smooth.

  • …to sub-rounded Each impact-resistant 15 mL tube contains garnet matrix and 10 (ten) 1/4 inch ceramic sphere. Lysing Matrix A is used for all sample types except soil for the subsequent isolation of genomic DNA. This grinding matrix is chemically inert and will not bind nucleic acids.

  • … Lysing Matrix D is used primarily for lysis of softer tissues like brain, liver, kidney, lung, and spleen. Also used to lyse plant tissue such a leaves, roots, and fruits, as well as cultured cells and whole insects. This grinding matrix is chemically inert and will not bind nucleic acids.

  • Lysing Matrix K is effective in breaking fungal spores, cysts, and yeast polysaccharide capsules. 0.8mm zirconium silicate beads Impact-resistant tube High density, tensile strength and hardness Lysing Matrices are critical components of the FastPrep™ Sample Preparation…

  • Lysing Matrix S, Bulk

    MP Biomedicals

    Lysing Matrix S is used to break hard/brittle samples. Impact-resistant tube RNA and protein extraction from difficult samples Lysis by impaction with minimal mechanical shearing Lysing Matrices are critical components of the FastPrep™ Sample Preparation system. MP…

  • Lysing Matrix S is used to break hard/brittle samples. Impact-resistant tube RNA and protein extraction from difficult samples Lysis by impaction with minimal mechanical shearing Lysing Matrices are critical components of the FastPrep™ Sample Preparation system. MP…

  • Lysing matrix C, 15mL tubes are for rapid and reliable biological sample lysis from a wide variety of starting materials. Lysing matrix C is a critical component of FastPrep® sample preparation system. Each impact-resistant 15 mL tube contains 1 mm silica spheres. Applications …

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.