Gravity Column

Compare Tool

Select up to 3 products

Gravity Column
1 - 32 of 79
Sort
View
Show
  • Spin Adapters for Gravity Columns

    GE Healthcare

    …rings designed for use with the gravity columns PD MiniTrap G-25, PD MidiTrap G-25, and PD-10 Desalting Columns when the spin protocol is used. MiniSpin Adapter fits PD MiniTrap G-25 columns, MidiSpin Adapter fits PD MidiTrap G-25 columns, and PD-10 Spin Adapter fits PD-10 Desalting Columns.

  • Empty Gravity Columns

    Expedeon

    These columns are designed for gravity purification using small quantities of resin of your choice. Two different column sizes are available: 0.5-2.0mL and 2-6mL bed volume.

  • Gravity Chromatography Columns

    DWK Life Sciences (Kimble)

    Gravity chromatography column manufactured from medium wall tubing with PTFE stopcock and in-line reservoir for containing liquid buffer Standard Taper joint size 24/40 These columns may be used alone or in combination with 420575-2440 flow control adapter A coarse porosity glass frit…

  • NUCLEODUR® C8 Gravity HPLC Columns

    MACHEREY-NAGEL

    …for modern HPLC phases. It is the result of MACHEREY-NAGEL's pioneering research in chromatography for almost 50 years. NUCLEODUR® C8 Gravity Nonpolar high density monomeric octyl modification, endcapped, USP L7 Key features: Suitable for LC/MS and HPLC at pH extremes (pH…

  • Empty Disposable PD-10 Columns

    GE Healthcare

    Columns with LabMate Buffer Reservoir for convenient equilibration, sample application, and wash.PD-10 Columns are economical, plastic columns for gravity flow purification. Empty Disposable PD-10 Columns are economical, plastic columns for single-use applications using gravity flow. The columns

  • NUCLEODUR® C18 Gravity HPLC Columns

    MACHEREY-NAGEL

    …modern HPLC phases. It is the result of MACHEREY-NAGEL's pioneering research in chromatography for almost 50 years. NUCLEODUR® C18 Gravity Nonpolar high Density octadecyl modification, USP L1 Properties / Key features Suitable for LC/MS and HPLC at pH extremes (pH…

  • NUCLEODUR® C8 Gravity VarioPrep HPLC Columns

    MACHEREY-NAGEL

    …backflushing techniques Allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column VP columns can be made in many column dimensions combination. Available lengths [mm]: 50, 75, 100, 125, 150, 250, 500 …

  • C Columns

    GE Healthcare

    …reservoirs for each column diameter optimize packing conditions.C columns are delivered with polyethylene tubing (1.0-mm ID, 2 m in length), bed support screens, snap-on net rings, and instructions.C columns are economical modular columns for low pressure or gravity feed, providing even…

  • NUCLEODUR® C18 Gravity VarioPrep HPLC Columns

    MACHEREY-NAGEL

    …backflushing techniques Allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column VP columns can be made in many column dimensions combination. Available lengths [mm]: 50, 75, 100, 125, 150, 250, 500 …

  • illustra NAP Columns

    GE Healthcare

    …purification, desalting and buffer exchange.Disposable columns prepacked with Sephadex G-25 DNA Grade which require only gravity to run. NAP Columns are disposable columns prepacked with Sephadex G-25 DNA Grade and require only gravity to run. Each package includes a complete step-by-step protocol…

  • NUCLEODUR® C18 Gravity-SB HPLC Columns

    MACHEREY-NAGEL

    NUCLEODUR® is a fully synthetical type B silica (silica of 3rd generation) offering highly advanced physical properties: Totally spherical particle shape Outstanding surface microstructure High pressure stability Low metal content NUCLEODUR® as a state-of-the-art silica…

  • NUCLEODUR® C18 Gravity-SB VarioPrep HPLC Columns

    MACHEREY-NAGEL

    …backflushing techniques Allows compensation of a dead volume, which could result at the column inlet after some time of operation, without need for opening the column VP columns can be made in many column dimensions combination. Available lengths [mm]: 50, 75, 100, 125, 150, 250, 500 …

  • Flex-Column Economy Chromatography Column Accessories

    DWK Life Sciences (Kimble)

    …diffusion disc from the column Packing Reservoir Funnels The funnels are used for initial column packing and as a small buffer reservoir. Available in two capacities: 100 mL for the 0.7, 1.0 cm and 1.5 cm ID columns and 700 mL for the 2.5 cm columns Manufactured from…

  • Chromatography Columns

    Chemglass

    General purpose gravity eluted column having a PTFE stopcock and reinforced beaded top. Column is constructed using MEDIUM WALL TUBING. Glass wool (not supplied) is used to support column packing. Lower end of the column has a round bottom.

  • Cu-IMAC Columns

    bioWORLD

    Cu-immobilized metal affinity chromatography (IMAC) columns consist of Cu-Chelated Separopore®matrix conveniently prepacked spin columns for gravity flow chromatography. Cu-IMAC Columns separate proteins via their differences in affinity to Cu2+ metal ions. Ideal for purification of recombinant…

  • Sephadex G-25 in PD-10 Desalting Columns

    GE Healthcare

    …labels) from samples using gravity flow or centrifugation. What comes in the PD-10 column package? Each product pack includes 30 columns, a buffer tray, a column stand, and 4 adapters for centrifugation. Versatile for use with centrifugation or gravity flow The product…

  • Zn-IMAC Columns

    bioWORLD

    Zn-immobilized metal affinity chromatography (IMAC) columns consist of Zn-Chelated Separopore®matrix conveniently prepacked spin columns for gravity flow chromatography. Zn-IMAC Columns separate proteins via their differences in affinity to Zn2+ metal ions. Ideal for purification of recombinant…

  • illustra NICK Columns

    GE Healthcare

    …labeled nucleotides NICK Columns were originally designed for purification of nick-translated DNA fragments but are also suitable for separation of any labeled probe from unincorporated labeled nucleotides. They are ready for immediate use, and operate by gravity flow. Tests show that at least…

  • Ni-IMAC 1mL Columns

    bioWORLD

    Ni-immobilized metal affinity chromatography (IMAC) columns consist of Ni-Chelated Separopore®matrix conveniently prepacked spin columns for gravity flow chromatography. Ni-IMAC Columns separate proteins via their differences in affinity to nickel metal ions. Ideal for purification of recombinant…

  • His GraviTrap TALON

    GE Healthcare

    …can be applied all at once.His GraviTrap TALON® is a prepacked gravity flow column for convenient manual purification of histidine-tagged proteins. His GraviTrap TALON® gravity flow columns are designed for convenient and efficient gravity flow purification of histidine-tagged proteins directly from…

  • PD MidiTrap G-10

    GE Healthcare

    …in the volume range 400 to 1000 ?l.PD MidiTrap G-10 columns are prepacked, single-use gravity columns for buffer exchange and cleanup of biological samples, for example peptides, small proteins, and oligosaccharides PD MidiTrap G-10 gravity columns give fast and simple desalting and buffer exchange…

  • PD MiniTrap G-10

    GE Healthcare

    …the volume range of 100 to 300 ?l.PD MiniTrap G-10 columns are prepacked, single-use gravity columns for buffer exchange and cleanup of biological samples, for example peptides, small proteins, and oligosaccharides PD MiniTrap G-10 gravity columns give fast and simple desalting and buffer exchange…

  • PD MidiTrap G-25

    GE Healthcare

    …protocol with all gravity columns PD MidiTrap G-25 is designed for convenient desalting and buffer exchange of biological samples and volumes up to 1.0 ml can be handled. Two alternative application protocols are available, gravity or centrifugation. By using the gravity protocol, a simple…

  • 20mL Empty Disposable Columns

    G-Biosciences

    Our 20mL empty, plastic, disposable columns, designed for small scale gravity flow purifications, have an internal volume of 32mL and a resin bed volume of 20mL.  The columns are supplied with screw caps and stoppers. Features Total Volume: 32mL Resin Volume: 20mL Reservoir…

  • GST Bulk Kit

    GE Healthcare

    …of GST-tagged proteins using gravity flow columns or using batch purification with high specificity. Preserves protein antigenicity and function. Yields up to 50 mg of pure protein. For rapid purification of GST-tagged proteins using gravity flow columns or using batch purification with…

  • 10mL Spin Columns

    G-Biosciences

    These empty, plastic, disposable 10ml spin columns have an internal volume of 22ml and is designed for small scale purifications using 50ml centrifuge tubes. Supplied with screw cap and plastic stoppers. This columns are also ideal for gravity flow purifications Features Total…

  • illustra plasmidPrep Midi Flow Kit

    GE Healthcare

    …pipetting volume changes, color-coded kit components, and pre-equilibrated columns. Modified alkaline lysis procedure. Anion exchange chromatography. Purification is in single-use format, gravity fast flow columns. > 70% (strain-dependent) of supercoiled pDNA. Kit consistently produces…

  • 5mL Spin Columns

    G-Biosciences

    These empty, plastic, disposable 5ml spin columns have an internal volume of 8.5ml and is designed for small scale purifications using 15ml centrifuge tubes. Supplied with screw cap and plastic stoppers. This columns are also ideal for gravity flow purifications Features Total…

  • His GraviTrap

    GE Healthcare

    …GraviTrap is a prepacked, single-use column for purification of histidine-tagged proteins by immobilized metal affinity chromatography (IMAC). Column gives fast and simple gravity-flow purifications without any need for a purification The ready to use column is prepacked with Ni Sepharose 6 Fast…

  • GST GraviTrap

    GE Healthcare

    …disposable columns prepacked with 2 ml of Glutathione Sepharose 4B, sufficient for purification of up to 20 mg of fusion protein Convenient, prepacked gravity-flow columns. Allows direct purification of both clarified and unclarified cell lysates. Yields up to 20 mg of pure proteins per column.

  • Chromatography Columns with Standard Taper Joints

    Chemglass

    General purpose column has a PTFE stopcock and a top outer joint. Glass wool (not supplied) is used to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia…

  • Protein G GraviTrap

    GE Healthcare

    …on protein G ligands in gravity-flow columns. You do not need any other instrument with this protocol because the entire process relies on the flow of gravity. The yield varies from 20 to 50 mg of purified antibodies depending on the ligand you use. The columns are reusable up to five times.

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.