Glass Hydrometer Cylinder

Compare Tool

Select up to 3 products

Glass Hydrometer Cylinder
1 - 20 of 20
Sort
View
Show

Globe Scientific

  • quick-ship

    United Scientific Supplies

    Made from heavy borosilicate glass, these cylinders have a beaded top with a pouring spout and a round base for stability.

  • GSC International, Inc.

    250ml - Borosilicate Glass, Ungraduated Cylinder

  • Vee Gee Scientific

    VEE GEE Scientific Hydrometer Jars are made of borosilicate glass. Feature a beaded rim at the top and a circular base. Models 21000-250, 21000-500, and 21000-1000 are unmarked; model 21000-1000-L has a graduation line at 1000 mL for precise filling.

  • …performance liquid provides safe and easy cleanup in case of breakage. Scales are bold and easy to read. All instruments measure 15" in length and come with a built-in thermometer (range shown in listing). Hydrometer cylinder of at least 390 mm x 50 mm is required (See Thomas No. 6024Y50).

  • …6025F10 through F20 are for testing small quantities Models 6025C10 through C25 require a cylinder 340 x 38 mm diameter and approximately 250 mL of liquid for submersion. Models 6025F10 through F20 require a cylinder 150 mm deep x 25 mm i.d. and approximately 50 mL of liquid for submersion.

  • DWK Life Sciences (Kimble)

    Plain, ungraduated cylinder With a hexagonal base ground flat for stability

  • Breakage is minimized by the heavy wall construction The large hexagonal base, sealed to the cylinder body, increases stability and prevents the cylinder from rolling off lab bench tops

  • quick-ship

    Chase Instruments

    For liquids heavier than water Tolerance ±1 scale division Requires a cylinder 300 x 38 mm and 300 mL of liquid.

  • …tank and shelf and finished steel exterior. Variable speed control for magnetic stirrer, temperature control dial and on/off switches for motor and power. Brass hydrometer cylinders feature wide base for maximum stability and a convenient pour-out lip. NOTE: for glass cylinder, see 3542D35.

  • Microprocessor PID control provides quick temperature stabilization without overshoot Holds 12 hydrometer cylinders Can be used for Reid Vapor Pressure immersion type cylinders Conforms to ASTM D 323, D 1298, D 8074, D 6158 and related specifications Designed for density/gravity…

  • … Calibrated at 60°F within a tolerance of ±0.5 smallest scale division Approximate total length 305 mm, length of scale 150 mm Requires a cylinder 340 x 38 mm and approximately 250 mL of liquid. Tralle scale expresses percent by volume of alcohol as 0 to 100° Tralle.

  • quick-ship

    Chase Instruments

    …at 60°F Range from 0° to 100° in 1° divisions; 100° indicates a saturated solution of sodium chloride in water, i.e. 26.395% salt Approximate total length 305 mm, approximate length of graduated scale 150 mm Requires a cylinder 340 x 38 mm and 300 mL of liquid.

  • quick-ship

    DWK Life Sciences (Kimble)

    …is 18 inches Scale is durable white ceramic enamel Used in measuring particle size distribution in soil suspensions by means of a hydrometer (ASTM D 422 and AASHTO T88) While the 1,205 mL size is not specified in this method, it is useful in certain special cases. Both sizes have…

  • Chase Instruments

    …a tolerance of ±0.1° and otherwise in accordance with the requirements of the U.S. National Bureau of Standards Interval 0.1°; approximate total length 340 mm, approximate length of scale 140 mm, with graduations at least 1.4 mm apart Require a cylinder 38 x 375 mm and about 285 mL of liquid.

  • …length 310 mm, approximate length of graduated scale 140 mm Tolerance ±1 scale division Requires a cylinder 340 x 38 mm and approximately 260 mL of liquid. Models 6026Q20 and Q30 hydrometers have specific gravity scale in divisions of .002, Baume scale in 0.2°; 6026Q35 in 0.005 and 0.5°, 6026Q40…

  • …correction scale. Readings are made on hydrometers at the top of the meniscus when overflowing in a clean special PYREX® brand glass cylinder. They check laboratory determinations made with the Boot or Reischauer pycnometer. All instruments and cylinders must be kept clean. We have found…

  • …1° divisions, with red line at 20°C and with temperature correction scale Length 375 mm, approximate length of scale 120 mm, with graduations at least 1.2 mm apart Interval 0.1°; tolerance ±0.1° Require a cylinder 375 x 50 mm and approximately 500 mL of liquid.

  • For testing small quantities of liquids heavier than water Approximate total length 150 mm, approximate length of graduated scale 45 mm; interval 0.005 Tolerance ±2 scale divisions Requires a cylinder 150 mm deep x 25 mm i.d. and approximately 50 mL of liquid.

  • …135 mm, except range 1.000 to 2.000, which has scale approximately 150 mm long and is made without conventional enlarged bulb at bottom Tolerance ±1 scale divisions Requires a cylinder 340 x 38 mm and approximately 250 mL of liquid. Model 6025M25 has 0.002 interval; 6025M35 has .005 interval.

  • Chase Instruments

    Graduated in American Petroleum Institute scale in accordance with ASTM Hydrometer Standards E-100; API standard 526 As required for ASTM Standard D 287 Federal Test Method Standard No. 791, method 401.4; ANSI Z11.31; and API Standard 526 Maximum total length 335 mm, maximum length of scale…

Compare Tool

Select up to 3 products