Glass Hydrometer Cylinder
-
Hydrometer Cylinders
United Scientific SuppliesMade from heavy borosilicate glass, these cylinders have a beaded top with a pouring spout and a round base for stability.
-
-
Hydrometer Jar
Vee Gee ScientificVEE GEE Scientific Hydrometer Jars are made of borosilicate glass. Feature a beaded rim at the top and a circular base. Models 21000-250, 21000-500, and 21000-1000 are unmarked; model 21000-1000-L has a graduation line at 1000 mL for precise filling.
-
…performance liquid provides safe and easy cleanup in case of breakage. Scales are bold and easy to read. All instruments measure 15" in length and come with a built-in thermometer (range shown in listing). Hydrometer cylinder of at least 390 mm x 50 mm is required (See Thomas No. 6024Y50).
-
…6025F10 through F20 are for testing small quantities Models 6025C10 through C25 require a cylinder 340 x 38 mm diameter and approximately 250 mL of liquid for submersion. Models 6025F10 through F20 require a cylinder 150 mm deep x 25 mm i.d. and approximately 50 mL of liquid for submersion.
-
KIMAX Hydrometer Cylinders
DWK Life Sciences (Kimble)Plain, ungraduated cylinder With a hexagonal base ground flat for stability
-
PYREX Brand Hydrometer Cylinders
CorningBreakage is minimized by the heavy wall construction The large hexagonal base, sealed to the cylinder body, increases stability and prevents the cylinder from rolling off lab bench tops
-
Hydrometer Baume 0'-70'
Chase InstrumentsFor liquids heavier than water Tolerance ±1 scale division Requires a cylinder 300 x 38 mm and 300 mL of liquid.
-
…tank and shelf and finished steel exterior. Variable speed control for magnetic stirrer, temperature control dial and on/off switches for motor and power. Brass hydrometer cylinders feature wide base for maximum stability and a convenient pour-out lip. NOTE: for glass cylinder, see 3542D35.
-
Microprocessor PID control provides quick temperature stabilization without overshoot Holds 12 hydrometer cylinders Can be used for Reid Vapor Pressure immersion type cylinders Conforms to ASTM D 323, D 1298, D 8074, D 6158 and related specifications Designed for density/gravity…
-
Alcohol Hydrometer Tralle And Proof Scales
Chase Instruments… Calibrated at 60°F within a tolerance of ±0.5 smallest scale division Approximate total length 305 mm, length of scale 150 mm Requires a cylinder 340 x 38 mm and approximately 250 mL of liquid. Tralle scale expresses percent by volume of alcohol as 0 to 100° Tralle.
-
Glass Salimeter
Chase Instruments…at 60°F Range from 0° to 100° in 1° divisions; 100° indicates a saturated solution of sodium chloride in water, i.e. 26.395% salt Approximate total length 305 mm, approximate length of graduated scale 150 mm Requires a cylinder 340 x 38 mm and 300 mL of liquid.
-
KIMAX Cylinders
DWK Life Sciences (Kimble)…is 18 inches Scale is durable white ceramic enamel Used in measuring particle size distribution in soil suspensions by means of a hydrometer (ASTM D 422 and AASHTO T88) While the 1,205 mL size is not specified in this method, it is useful in certain special cases. Both sizes have…
-
Brix Precision Hydrometers
Chase Instruments…a tolerance of ±0.1° and otherwise in accordance with the requirements of the U.S. National Bureau of Standards Interval 0.1°; approximate total length 340 mm, approximate length of scale 140 mm, with graduations at least 1.4 mm apart Require a cylinder 38 x 375 mm and about 285 mL of liquid.
-
High-Range Specific Gravity-Baume Hydrometers
Chase Instruments…length 310 mm, approximate length of graduated scale 140 mm Tolerance ±1 scale division Requires a cylinder 340 x 38 mm and approximately 260 mL of liquid. Models 6026Q20 and Q30 hydrometers have specific gravity scale in divisions of .002, Baume scale in 0.2°; 6026Q35 in 0.005 and 0.5°, 6026Q40…
-
…correction scale. Readings are made on hydrometers at the top of the meniscus when overflowing in a clean special PYREX® brand glass cylinder. They check laboratory determinations made with the Boot or Reischauer pycnometer. All instruments and cylinders must be kept clean. We have found…
-
Brix Precision Thermo-Hydrometers
Chase Instruments…1° divisions, with red line at 20°C and with temperature correction scale Length 375 mm, approximate length of scale 120 mm, with graduations at least 1.2 mm apart Interval 0.1°; tolerance ±0.1° Require a cylinder 375 x 50 mm and approximately 500 mL of liquid.
-
Hydrometers, Specific Gravity 1 To 1.4
Chase InstrumentsFor testing small quantities of liquids heavier than water Approximate total length 150 mm, approximate length of graduated scale 45 mm; interval 0.005 Tolerance ±2 scale divisions Requires a cylinder 150 mm deep x 25 mm i.d. and approximately 50 mL of liquid.
-
Hydrometers, Specific Gravity 1 To 2
Chase Instruments…135 mm, except range 1.000 to 2.000, which has scale approximately 150 mm long and is made without conventional enlarged bulb at bottom Tolerance ±1 scale divisions Requires a cylinder 340 x 38 mm and approximately 250 mL of liquid. Model 6025M25 has 0.002 interval; 6025M35 has .005 interval.
-
Long Form Petroleum API
Chase InstrumentsGraduated in American Petroleum Institute scale in accordance with ASTM Hydrometer Standards E-100; API standard 526 As required for ASTM Standard D 287 Federal Test Method Standard No. 791, method 401.4; ANSI Z11.31; and API Standard 526 Maximum total length 335 mm, maximum length of scale…