Glass Filter

Compare Tool

Select up to 3 products

Glass Filter
1 - 32 of 852
Sort
View
Show
  • 934-AH™ Borosilicate Glass Microfiber Filters

    GE Healthcare

    …temperatures. As specified for the analysis of water and waste samples in the Standard Methods for the Examination of Water and Wastewater (1992) Retains precipitates such as silver chloride Compares favorably with fritted glass filter crucibles Maximum usable temperature 500°C

  • Whatman Grade 934-AH Glass Microfiber Filters, Binder Free

    GE Healthcare

    …934-AH borosilicate glass microfiber filters from GE are smooth water quality filters with high retention efficiency. Grade 934-AH filters are often used in total suspended solids analysis. Grade 934-AH: 1.5 µm Discover other binder-free Whatman glass microfiber filters from GE Healthcare’s…

  • Holmium Oxide Glass Filter

    PerkinElmer

    Holmium oxide glass filter for checking the wavelength accuracy of a UV/Vis or UV/Vis/NIR spectrometer. The filter is mounted in precision aluminium spring mount and is provided in a robust aluminium container with a Certificate of Calibration.

  • Glass Filter Disc

    Ace Glass

    Filter discs, available in glass fiber or granular type. Glass fiber filter discs last longer, are more abrasion resistant, and are superior in performance than granular type discs. Granular discs for analytical and general bacteria filtration are avai

  • GF/A Borosilicate Glass Microfiber Filters

    GE Healthcare

    …particles to 1.6 µm Extremely high flow rate; filtration takes place both vertically and laterally through the filters High loading capacity, which continues to filter efficiently for a greater extended period Highly resistant to chemical attack; absence of binders ensures that…

  • Borosilicate Glass Filter Crucibles

    Corning

    Fused, fritted glass disc Polished ends Pore size: coarse, 40-60 µm, medium, 10-15 µm, fine 4-5.5 µm 30 mL disc diameter: 30 mm; fits tube i.d. 36 mm, 50 mL disc diameter: 40 mm; fits tube i.d. 42 mm.

  • Glass Fiber Filter Disks

    Celltreat Scientific

    Glass Fiber Filter Disks are an ideal prefilter to prevent clogging when filtering viscous or particulate-laden solutions with CELLTREAT Scientific Products vacuum Filter Systems and Bottle Top Filters. Increase filtration speed by removing larger part

  • Grade GF/C Glass Microfiber Filters

    GE Healthcare

    Grade GF/C is the standard filter in many parts of the world for the collection of suspended solids in potable water and natural and industrial wastes. Grade GF/C: 1.2 µm Combines fine particle retention with good flow rate. Fast and efficient clarification of aqueous liquids…

  • Bluestem Glass Solvent Filter

    Restek

    …Bluestem glass solvent filter. Restek Bluestem glass solvent filter provides clean mobile phase to extend the life of columns and pump seals 15 µm borosilicate glass frit sits lower than conventional glass filters to draw more mobile phase from each bottle Blue filter stem allows…

  • AP40 Glass Fiber Filter

    MilliporeSigma

    This 90 mm hydrophilic Glass Fiber filter with a 0.7 µm pore size is recommended prefilter for 0.9 to 8um filters, especially for proteinaceious & heavily contaminated liquids. Can be sterilized by EO, gamma & autoclave. Filter Color: White Thickness: 475 µm …

  • Glass Fiber Filter Microplates

    Agilent Technologies

    We offer filtration microplates in a range of filtration media, including glass fiber, polyethylene, polypropylene, nylon, polyethersulphone (PES) and polyvinylidene fluoride (PVDF). Four well configurations (140µl to 15ml/well) are available. The microplates are suitable for vacuum/positive…

  • GF/D Borosilicate Glass Microfiber Filters

    GE Healthcare

    …speed; ten times more rapid than the fastest comparable retention cellulose filter paper Withstands temperature to 500°C Designed as a membrane pre-filter, with sizes to fit most holders Used for sample collecting and testing in clinical screening; borosilicate glass without binders

  • TSS Glass Fiber Filters

    Hach

    TSS Filters are recommended for use in Standard Methods 2540 C and 2540 D. Optimized surface characteristics of this binderless borosilicate glass microfiber filter eliminates pin-holing and fiber-shedding to ensure consistent, accurate results comparable to 934-AH® brand filters. Fast flow…

  • Grade GF/F Glass Microfiber Filters, Binder Free

    GE Healthcare

    glass. GF/F offers very fine particle retention and good loading capacity and flow rate. 0.7 µm nominal particle retention Served as the basis filter for EPA standard for the toxicity characteristic leaching procedure GE’s Whatman brand glass microfiber filters provide…

  • Whatman Grade GF/A Glass Microfiber Filters, Binder Free

    GE Healthcare

    …of binder-free glass microfiber filters for different sample types and analysis needs. For higher wet strength, increased loading capacity, or different particle retention, see GE’s other Whatman binder-free filter options. Whatman glass microfiber filters without binder Filters that combine…

  • Grade 934-Ah Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Glass Microfiber Filters

    Ahlstrom

    …Widely used as a depth type pre-filter ahead of final membrane filters. Sometimes used in combination with grade 121 as a graded porosity protective and retentive pre-filter for highly-efficient protection of membrane filters. GRADE 131 (1.0 µm): Binder-free grade, found in many…

  • Glass Fiber Filters

    Sartorius

    Depth filters with high particle loading capacity. Made of 100% borosilicate. Temperature resistant up to 500 °C. Typically placed directly on top of other membrane filters to act as a prefilter; or may be used to filter solutions directly.

  • GF/B Borosilicate Glass Microfiber Filter Discs

    GE Healthcare

    …particles to 1.0 µm Extremely high flow rate; filtration takes place both vertically and laterally through the filters High loading capacity, which continues to filter efficiently for a greater extended period Highly resistant to chemical attack; absence of binders ensures that…

  • 25mm Glass Fiber Syringe Filters

    J.G. Finneran

    Finneran 25mm Glass Fiber Syringe Filters are available in 0.2um and 0.45 um pore size. Autoclavable.

  • Glass Microfiber Filters

    Sartorius

    Depth filters with high particle loading capacity. Made of 100% borosilicate. Temperature resistant up to 500 °C. Typically placed directly on top of other membrane filters to act as a prefilter; or may be used to filter solutions directly.

  • Whatman Multigrade 150 Glass Fiber Filters

    GE Healthcare

    …borosilicate glass, binder-freeExtends life of final filter membraneGE’s Whatman GMF 150 prefilters are multilayer graded density filters for rapid and efficient filtration of samples with high solids content. Multilayer filter design When a sample is applied, the multigrade glass filter traps…

  • TCLP Glass Fiber Filters

    Designed to meet requirements for use in U.S. EPA SW-846 Method 1311: Toxic Characteristics Leaching Procedure (TCLP).

  • KIMAX Glass Buchner Filter Funnels

    DWK Life Sciences (Kimble)

    Kimble 28400 With fused-in fritted discs Designed from Federal Specification DD-F-776 Dimensions are identical with corresponding sizes of 5220F28 series. Type designates capacity (in mL) and porosity.

  • Grade A Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Grade C Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Grade A-E Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Grade B Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Whatman Grade GF/C Glass Microfiber Filters, Binder Free

    GE Healthcare

    …offers glass microfiber filters with a range of pore sizes and thicknesses. Total suspended solids filter Whatman Grade GF/C filters from GE are widely used as a total suspended solids filter for applications testing both potable water and waste water. GF/C can also function as a filter

  • Grade F Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Whatman Grade GF 10 Glass Microfiber Filters with Binder

    GE Healthcare

    Whatman Grade GF 10 glass microfiber filters from GE Healthcare’s Life Sciences business are made from borosilicate glass and strengthened with an organic binder to provide high mechanical stability. Temperature resistance up to 180°C Strengthened with high-quality organic…

  • Grade GF 8 Glass Microfiber Filters with Binder

    GE Healthcare

    Grade GF 8 glass microfiber filter used in the filtration of coarse particles. Grade GF 8: Inorganic binder This glass fiber filter is used in the filtration of coarse particles. Frequently used in: Environmental analysis, in the determination of PCB, DDE, DDT, furans, and dioxins in the…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.