  • Glass Fiber Filters

    Sartorius

    Depth filters with high particle loading capacity. Made of 100% borosilicate. Temperature resistant up to 500 °C. Typically placed directly on top of other membrane filters to act as a prefilter; or may be used to filter solutions directly.

  • TSS Glass Fiber Filters

    Hach

    TSS Filters are recommended for use in Standard Methods 2540 C and 2540 D. Optimized surface characteristics of this binderless borosilicate glass microfiber filter eliminates pin-holing and fiber-shedding to ensure consistent, accurate results comparable to 934-AH® brand filters. Fast flow…

  • Glass Fiber Filters without Binder Resin

    MilliporeSigma

  • Glass Fiber Filters, Water Quality Testing

    Advantec MFS

    Advantec Glass Fiber Depth Filters feature high-loading capacity, fast flow rates, are highly resistant to chemical attack, and biologically inert. General purpose and clarifying filtration grades. Binder-free and thermostable to 500°C. Grade GA55 is a thin filter recommended for…

  • Glass Fiber Filters with Binder Resin

    MilliporeSigma

    …disc filters are available in a wide range of flow rates and throughput capacities. Glass fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar). Glass Fiber Filters with Binder Resin Millipore filters with binder…

  • Glass Fiber Binderless Filter 1.0um 90mm

    GVS Life Sciences

    No binder extractables Recommended for temperatures up to 510°C (950°F). Porosity micron: 1 Sterile: No Hydrophobic : No Kind : disk Dimension mm : 90 Grade : Plain Pad : NA

  • 25mm Glass Fiber Syringe Filters

    J.G. Finneran

    Finneran 25mm Glass Fiber Syringe Filters are available in 0.2um and 0.45 um pore size. Autoclavable.

  • Glass Fiber Filters with Binder Resin

    MilliporeSigma

    …Recommended prefilter for 0.2 to 0.6 µm filters Type AP20 Lower retention, higher dirt-holding capacity than AP15 filters Recommended prefilter for 0.8 to 8.0 µm filters Use upstream to protect type AP15 filters Type AP25 Added thickness yields…

  • AP40 Glass Fiber Filter

    MilliporeSigma

    This 90 mm hydrophilic Glass Fiber filter with a 0.7 µm pore size is recommended prefilter for 0.9 to 8um filters, especially for proteinaceious & heavily contaminated liquids. Can be sterilized by EO, gamma & autoclave. Filter Color: White Thickness: 475 µm …

  • Grade A-E Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Standard TCLP Filters

    Environmental Express

    Binder-free borosilicate glass fiber filters have porosity limits of 0.7µm +/- 0.1µm and exhibit a 98% particle retention rate at that particle size.

  • 934-AH™ Borosilicate Glass Microfiber Filters

    GE Healthcare

    …particles to 1.5 µm Extremely high flow rate; filtration takes place both vertically and laterally through the filters High loading capacity, which continues to filter efficiently for a greater extended period Highly resistant to chemical attack; absence of binders ensures that…

  • Whatman Grade GF/F Glass Microfiber Filters, Binder Free

    GE Healthcare

    …analysis in the Whatman binder-free range. Glass fiber TCLP test filters When the U.S. Environmental Protection Agency (EPA) Toxicity Characteristic Leaching Procedure 1311 was developed, it recommended using the Whatman Grade GF/F filter. Grade GF/F remains a popular and prominent component…

  • Whatman Multigrade 150 Glass Fiber Filters

    GE Healthcare

    …borosilicate glass, binder-freeExtends life of final filter membraneGE’s Whatman GMF 150 prefilters are multilayer graded density filters for rapid and efficient filtration of samples with high solids content. Multilayer filter design When a sample is applied, the multigrade glass filter traps…

  • Grade C Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Glass Fiber Binder Filter 0.5um 142mm

    GVS Life Sciences

    Acrylic binder High dirt holding capacity Biologically inert Bonding reduces media migration

  • Thomas Grade D Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Glass Fiber Filters without Binder Resin

    MilliporeSigma

  • Glass Fiber Filters, Air Monitoring

    Advantec MFS

    Advantec Glass Fiber Filters are depth filters made of pure borosilicate glass microfibers. Highly resistant to chemical attack and biologically inert. Binder-free and thermostable to 500°C. These grades are recommended primarily used in environmental air monitoring applications. Grade…

  • Glass Fiber Filters without Binder Resin

    MilliporeSigma

    …fibrous disc filters are available in a wide range of flow rates and throughput capacities. Glass fiber filters are available with or without binder resins and can be sterilized by EO, gamma, or autoclave (121 °C at 1 bar). Glass Fiber Filters without Binder Resin The filters without…

  • Glass Fiber Filters, Thicker for Viscous Liquids

    Advantec MFS

    Advantec Glass Fiber Filters are depth filters made of pure borosilicate glass microfibers. These grades are thicker and have a high loading capacity and typically faster flow times. Recommended for filtering viscous fluids such as proteinaceous solutions and gels and as prefilter to extend membrane…

  • Glass-Fiber Membrane Prefilters

    Thermo Scientific Nalgene

    Nalgene 281 Extends the life of membrane filters Thin, non-sterile Autoclavable Glass-fiber prefilters are for use with Nalgene disposable filter units.

  • Grade F Glass Microfiber Filters

    Thomas®

    …efficiency rating of the filter is characteristic of the complex pore structure that develops as the fibers overlap. The fibrous material within the filter is commonly glass micro fiber or polypropylene. In depth filters such as glass micro fiber, the purity of the filter is dictated by the presence…

  • Glass Fiber Filters without Binder Resin

    MilliporeSigma

  • PTFE Depth Filters

    Advantec MFS

    Pure PTFE (Polytetrafluoroethylene) fibers are sintered to create a unique depth-type filter. These PTFE filters offer superior handling and minimal fiber slough-off compared to glass and quartz filters. Naturally hydrophobic, the media will separate aqueous from non-aqueous phases of mixtures.…

  • Glass Fiber Filters without Binder Resin

    MilliporeSigma

  • Glass Fiber Filters without Binder Resin

    MilliporeSigma

  • Glass Fiber Filters without Binder Resin

    MilliporeSigma

  • Glass Microfiber Filter Media, Grade 169

    Ahlstrom

    …precipitate is collected on a glass fiber filter, such as Grade 169, to measure its weight and radioactivity. STM 7500-Sr Strontium Detection: Precipitation Method The precipitate is collected on a paper filter, such as Grade 94, or a glass fiber filter, such as Grade 169, to measure its…

  • Syringe Filter: Glass Fiber

    Graphic Controls

    A syringe filter generally consists of a plastic housing with a membrane which serves as a filter. The fluid to be purified may be cleaned by drawing it up the syringe through the filter. We offer three filter diameters: 15mm, 25mm and 30mm with membranes made of the following materials: GF -…

  • TCLP Glass Fiber Filters

    Designed to meet requirements for use in U.S. EPA SW-846 Method 1311: Toxic Characteristics Leaching Procedure (TCLP).

  • UNIFILTER 96-Well 800µL Microplates

    GE Healthcare

    …ensures efficient use of materials. Better control. Choice of filter media allows control of the flow rates and retention characteristics. Versatile. A broad range of filtration media is available, including glass fiber, polypropylene, cellulose nitrate, cellulose acetate, nylon, and ion…