Glass Cold Trap
-
Glass Vacuum Cold Trap for Safe Vacuum Operations
Across International…to trap solvent. Liquid oxygen can be condensed into a cold trap if a pump has sucked air through the trap when the trap is very cold. Features Utilizes dry ice for optimal efficiency Comes with scissor jack for easy collection flask removal Easy to clean all glass construction…
-
Glass Trap for Ai -40°C Cold Traps (Second Generation)
Across International…International 500mL glass trap for Ai 2nd Gen T40 -40°C UL/CSA certified cold traps. Upward hose barb ports give you safer and easier vacuum tubing connection and removal. Attention! This new glass trap ONLY fits our new 2nd Gen UL/CSA certified T40 -40°C cold traps (released 9/2018).
-
Glass Traps for Ai T Series Cold Traps (First Generation only)
Across International…Glass Trap High quality 1-piece glass trap for Ai T series -40°C and -80°C cold traps. Features Inlet and outlet: 3/8" hose barb 2" OD x 10" height Glass material: high borosilicate glass 3.3 CTG-2P: Openable Glass Trap High quality glass trap…
-
Aquilon Cold Trap
Holland Green ScienceThe Aquilon cold trap is a device that condenses vapor into a liquid or solid (ice). The main purpose is to prevent vapors from entering the vacuum pump, where they would condense, contaminate vacuum pump oils and can cause corrosion. Whilst doing this task the cold trap further prevents vacuum pump…
-
CA Series Cold Traps
YamatoEfficiently traps water vapor and toxic substances discharged from vacuum oven and rotary evaporator to protect the vacuum pump Features Excellent choice to extract acid and organic solvents with the optional glass condenser Efficiently reduces vapor inhalation amount to the vacuum…
-
Trap Packing Disk
PerkinElmerGlass fiber disk tor separating sorbents when packing ATD cold trap with multiple sorbents. Recommended when using low flow trap.
-
Ai 2L SolventVap W/ Electric Lift And Cold Trap Condenser 110V
Across International…controller ensures accurate temperature control is maintained. Your safety is important to us! Please use caution when operating. Users of glass reaction equipment must take all necessary precautions to avoid contact with rotating parts, particularly entanglement of loose clothing, hair,…
-
High Vacuum System Trap
Ace GlassVacuum trap system protects gauge heads, like our 14034, and pumps from corrosive vapors and particle fouling. System consists of a Dewar flask, cold trap and inlet arm. High-vacuum stopcocks are used throughout. Gauge & inlet arm are Ace-Thred connections. Pump & manifold connections are o-ring…
-
Glass Jacketed Filter Reactor
Cascade Sciences LLCGlass jacketed filter reactor is a turnkey package for benchtop filter reactions, isolate production. Includes temp control, powerful stirring, clean, oil-free vacuum, cold trap, glass carboy, thermofluids, hoses, connection fittings.
-
…hooks that allow the trap to hang on the side of the RapidVap Vacuum System. Alternatively, the bracket serves as a stand to stabilize the glass container resting on a flat work surface. This trap may also be used with pre-2005 CentriVap Cold Traps. Liquid Trap prevents liquid from entering…
-
Ai 6" Glass Turnkey Thin Film Distillation Gen 2 ETL, 230V, 1ph, 2-5L/hr
Across International…down to -80°C (no dry ice needed) Installation included in the price within contiguous 48 US states Cold Traps are only suitable for use with dry ice or a cold finger chiller such as an IP-80 or TC100/TC100E. Always wear proper PPE when handling dry ice. ETL tested to…
-
CentriVap Acid-Resistant System
LabconcoThe CentriVap Vacuum Concentration System includes the following components: Acid-Resistant Benchtop Vacuum Concentrator with Glass Lid 7810016; Cold Trap 7811020; Clear Canister 7460900; Acid Insert 7814800; 12-13 mm Acid-Resistant Rotor 7455101; Glass Trap 7397605; and Vacuum Tubing and 6 Clamps.
-
The CentriVap Vacuum Concentration System includes the following components: Acid-Resistant Benchtop Vacuum Concentrator with Glass Lid, Cold Trap, Clear Canister, Acid Insert, 12-13 mm Acid-Resistant Rotor, Glass Trap, and Vacuum Tubing and 6 Clamps.
-
Centrivap Concentrator Systems
Labconco…catalog number. Just add a vacuum pump and you will be ready to concentrate your samples! CentriVap Solvent Systems are for concentrating organic solvents. They include a Benchtop Concentrator with Glass Lid, Glass Lid Cold Trap, Clear Canister, Solvent Insert, 12-13 mm Rotor and Vacuum Tubing.
-
Parts & Accessories for Ai SolventVap Rotary Evaporators
Across International…out of your rotary evaporators. Comes with two 3/8" hose barb connectors, and a detachable bottle holder. Glass Cold Trap (Dry Ice) Condenser High quality glass cold trap (dry ice) condenser with lid. No chillers needed, utilizes dry ice for optimal efficiency. Designed and specially…
-
… Glass Assembly: C (Cold trap) for low boiling point solvents Protective Coating: Without Recirculating Chiller: Without Vacuum Controller: I-100, with Woulff bottle Vacuum Pump: V-100, 1.5 m3/h, 10 mbar 1190U73 Glass Assembly: C (Cold trap) for low boiling…
-
Turnkey wiped film system
Cascade Sciences LLC…wiped film system for precise distillations. Complete system includes 2-liter Jacketed Fill Funnel, all temperature control of the glass jacketed fill funnel, main body, condensor, cold fingers and cold trap. Powerful PTFE wiper stirring, deep vacuum, and professional Installation.
-
Traps, C Set, Rotary Evaporator
Ace GlassBorosilicate glass components for model R220 rotary evaporators. Traps are both inner and outer cold traps available either safety coated or plain. This improved version utilizes flat ground flanges on the inner and outer trap that is sealed together with a Duran quick- release clamp. Outer traps…
-
… solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also be installed. 1230D92 - Secondary Cold Trap, Glass, If dry ice is used instead of cooling water, a suitable cold trap can also be installed.
-
…residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also be installed. 1230D92 - Secondary Cold Trap, Glass, If dry ice is used instead of cooling water, a suitable cold trap can also be installed.
-
Savant™ SpeedVac Universal Vacuum Systems
Thermo Scientific…and vapor path Post trap Ammonia Neutralizing Trap (ANT100) included Includes the VaporNet™ technology. This represents a valve in the vacuum line and a control circuit for that valve. Modulating this valve causes molecules to remain in the cold trap for longer than would be…
-
…features PTFE diaphragms and a fluoropolymer flowpath for excellent corrosion resistance. Catchpots are made of borosilicate glass. Many applications do not require a cold trap. Quiet, Trouble-Free Operation. The MZ2C NT Synchro operated near ultimate vacuum is whisper quiet, with sound…
-
…features PTFE diaphragms and a fluoropolymer flowpath for excellent corrosion resistance. Catchpots are made of borosilicate glass. Many applications do not require a cold trap. Quiet, Trouble-Free Operation. The MD4C NT Synchro operated near ultimate vacuum is whisper quiet, with sound…
-
MZ2C NT+2AK Dry Chemistry Diaphragm Pump
BrandTech®…features PTFE diaphragms and a fluoropolymer flowpath for excellent corrosion resistance. Catchpots are made of borosilicate glass. Many applications do not require a cold trap. Quiet, Trobule-Free Operation. The MZ2C NT+2AK operated near ultimate vacuum is whisper quiet, with sound pressure…
-
Side Seal Joints
Chemglass…sizes are compatible with Buchi Rotary Evaporators. Part number CG-132-02 has a single sidearm and a drip tip permitting the seal to be made for the PTFE feed tube. Part number CG-132-03 has two sidearms sealed 180° apart and is used for replacement on the vertical cold trap condenser assembly.
-
Distillation Apparatus, Cyanide
Ace Glass…valve for added protection against boil back. Jacketed still head is lengthened for efficient condensing. Head and cold finger have a 29/42 joint and #11 Ace-thred on side arm. Two #11 bushings hold the threaded adapter to still head. 10-20m frit, 19/22 trap joint, and 8mm side arm threaded adapter.
-
Ai 6" Stainless Turnkey Thin Film Distillation Gen 2 ETL - 230V, 1ph, 3-8L/hr
Across International…for mobility and stability Redesigned drain port with sight glass for easy cleaning and maintenance. Installation included in the price within contiguous 48 US states Cold Traps are only suitable for use with dry ice or a cold finger chiller such as an IP-80 or TC100/TC100E. Always wear…
-
Savant™ SpeedVac™ SPD2030 Integrated Vacuum Concentrator Systems
Thermo Scientific…Savant™ SpeedVac™ SPD1030 and SPD2030 Vacuum Concentrators are fully integrated systems that combine concentrator, refrigerated cold trap, diaphragm pump and vacuum gauge in a single, compact unit. Convenience and Flexibility in two capacity ranges The Savant SpeedVac SPD1030…
-
Savant™ SpeedVac™ SPD1030 Integrated Vacuum Concentrator Systems
Thermo Scientific…Savant™ SpeedVac™ SPD1030 and SPD2030 Vacuum Concentrators are fully integrated systems that combine concentrator, refrigerated cold trap, diaphragm pump and vacuum gauge in a single, compact unit. Convenience and Flexibility in two capacity ranges The Savant SpeedVac SPD1030…