Flash Column
-
…phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography…
-
…polar and basic compound—ideal for carbohydrates Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or with vacuum processing stations. All columns are made from polypropylene and come with polyethylene frits.
-
…Optimized column geometry provides maximum recovery Bonded octadecyl stationary phase offers reverse phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns…
-
Flash glass columns
MACHEREY-NAGELGlass columns and kits for low pressure flash chromatography Economic low-tech method for the synthesis laboratory Suited for the separation of compounds up to gram levels No expensive equipment required MN flash chromatography kits include a glass column, eluent reservoir, silica 60…
-
CHROMABOND® Flash Columns and Connecting Kits
MACHEREY-NAGEL…ferrules; 2 x 1/4"-28 nylon unions; 2 x 1/4"-28 PP nuts CHROMABOND® Flash DL empty columns Can be used as solid injection system or for self-filling and packing of flash cartridges Column connection: female Luer lock inlet and male Luer lock outlet Each cartridge comes…
-
…peak shapes with polar and basic compound—ideal for carbohydrates Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.
-
…column geometry provides maximum recovery Use to separate primary, secondary, and tertiary amines NH2 shows better peak shapes with polar and basic compound—ideal for carbohydrates Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are…
-
Optimized column geometry provides maximum recovery Excellent for purification of a wide range of synthetic and natural compounds Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings…
-
…and Buchi® Optimized column geometry provides maximum recovery Excellent for purification of a wide range of synthetic and natural compounds Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are made of polypropylene and have…
-
…reverse phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or with vacuum processing stations. All columns are made from…
-
Ideal for first stage clean-up columns post synthesis using a vacuum manifold Excellent for purification of a wide range of synthetic and natural compounds Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or…
-
…make a pressure-tight, O-Ring compression seal with glass stem on reservoir & flow adapter. Bushing replaces joint clamp. Column & reservoir, only, are Epoxy Coated. Column available with or without Por.B (70-100m) fritted disc sealed in. Order each item separately for complete system.
-
…chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and adapter…
-
…chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g3 in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and adapter…
-
CHROMABOND® Flash BT Cartridges
MACHEREY-NAGELIdeal for Flash separations from 10 mg up to 33 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…
-
CHROMABOND® Flash RS SiOH Cartridges
MACHEREY-NAGELIdeal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…
-
Use when samples need to be pre-absorbed onto loose sorbent material Suitable for dry loading and packing home-built columns The TELOS bulk sorbents for flash chromatography dry loading are available in silica, NH2 (bonded aminopropyl), C18 (octadecyl), and NM (diatomaceous earth). Silica,…
-
CHROMABOND® Flash RS SPHERE SiOH Cartridges
MACHEREY-NAGELIdeal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…
-
CHROMABOND® Flash RS C18 ec Cartridges
MACHEREY-NAGELIdeal for Flash separations from 10 mg up to 300 g Features For convenient operation and reliable upscaling the complete program of ready-to-use Flash cartridges for the Isco Companion® and other Teledyne Isco CombiFlash® systems, or as stand-alone version for all…
-
Supeltex® M-4 Packed Column Ferrule
MilliporeSigma…clean, sharp profile with minimal flash.Characteristics: Seals at one-quarter turn past fingertight. Maximum sealing surface contact, reduced risk of column contamination at installation.Material Composition: flexible graphiteMaximum Temperature: 450 C Legal Information: Supeltex is a registered…
-
Supeltex® M-4 Packed Column Ferrule
MilliporeSigma…clean, sharp profile with minimal flash.Characteristics: Seals at one-quarter turn past fingertight. Maximum sealing surface contact, reduced risk of column contamination at installation.Material Composition: flexible graphiteMaximum Temperature: 450 C Legal Information: Supeltex is a registered…
-
TELOS® Dry Loading Columns
KinesisColumns are prefitted with a bottom frit Use dry loading columns with bulk sorbents to quickly and easily apply to flash chromatography system. Attach dry loading columns directly to the main flash columns to suit majority of reaction scales. Columns feature Luer-lok® inlet and Luer-slip…
-
SYNTHWARE Chromatography Columns with Reservoirs
Kemtech America…chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Top Joint: ST 24/40 Note: since the chromatography column is used…
-
SYNTHWARE Modified Chromatography Columns
Kemtech AmericaSYNTHWARE short chrmoatography column with a lower standard taper 24/40 inner joint with a sealed in drip tip and a hose connection. Designed to perform seperations using a vacuum source. All sizes have a fritted disc to support column packing.
-
SYNTHWARE Chromatography Columns with Spherical Joints
Kemtech America…purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top spherical socket joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Joint: SJ 35/20 Note: since the chromatography column is used with positive air…
-
SYNTHWARE Chromatography Columns with Teflon® Stopcocks
Kemtech America…general purpose chromatography column with heavy wall design. With reinforced beaded top. Supplied with a PTFE stopcock. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with positive air pressure,…
-
General purpose column having a PTFE stopcock and a top Rodaviss® outer joint. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC CHEMISTRY 43, 2923 [1978], and covered in U.S. Patent Number…
-
General purpose column has a PTFE stopcock and a top outer joint. Glass wool (not supplied) is used to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia…
-
SYNTHWARE Heavy Wall Design Chromatography Columns
Kemtech America…purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Top Joint: ST 24/40. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with positive…
-
…chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top spherical socket joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Joint: SJ 35/20 Note: since the chromatography column is used with…
-
Similar to CG-1196 but with a COARSE porosity sealed in fritted disc to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC…
-
Similar to CG-1188 but with a sealed in COARSE porosity fritted disc to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC…
