Flash Chromatography Column

Compare Tool

Select up to 3 products

Flash Chromatography Column
1 - 32 of 55
Sort
View
Show

GFS

  • …phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography

  • …peak shapes with polar and basic compound—ideal for carbohydrates Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • …Excellent for purification of a wide range of synthetic and natural compounds Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • …phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back…

  • … NH2 shows better peak shapes with polar and basic compound—ideal for carbohydrates Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • … Excellent for purification of a wide range of synthetic and natural compounds Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • …purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Top Joint: ST 24/40 Note: since the chromatography column is…

  • …reverse phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or with vacuum processing stations. All columns are made from…

  • SYNTHWARE general purpose chromatography column with heavy wall design. With reinforced beaded top. Supplied with a PTFE stopcock. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with positive air…

  • Ideal for first stage clean-up columns post synthesis using a vacuum manifold Excellent for purification of a wide range of synthetic and natural compounds Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or…

  • … Pure C-810 / C-815 Flash More purification in a very convenient way Pure C-810 / C-815 Flash are two advanced and powerful flash systems designed to get more purification in less space, as they belong to the smallest chromatography systems on the market be operated…

  • …polar and basic compound—ideal for carbohydrates Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or with vacuum processing stations. All columns are made from polypropylene and come with polyethylene frits.

  • …general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Top Joint: ST 24/40. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with…

  • …make a pressure-tight, O-Ring compression seal with glass stem on reservoir & flow adapter. Bushing replaces joint clamp. Column & reservoir, only, are Epoxy Coated. Column available with or without Por.B (70-100m) fritted disc sealed in. Order each item separately for complete system.

  • …absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a reinforced beaded top. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully minimized to prevent…

  • …absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g3 in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top standard taper outer joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully minimized to…

  • Use when samples need to be pre-absorbed onto loose sorbent material Suitable for dry loading and packing home-built columns The TELOS bulk sorbents for flash chromatography dry loading are available in silica, NH2 (bonded aminopropyl), C18 (octadecyl), and NM (diatomaceous earth). Silica,…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is…

  • …TELOS flash column installation Luer connections ensure leak-free chromatography Flash column holders accommodate any combinations of TELOS dry loading columns (4 to 40 g) and TELOS flash columns (4 to 330 g). Easily increase the capacity by installing two 120 g columns in series. Column

  • Flash glass columns

    MACHEREY-NAGEL

    Glass columns and kits for low pressure flash chromatography Economic low-tech method for the synthesis laboratory Suited for the separation of compounds up to gram levels No expensive equipment required MN flash chromatography kits include a glass column, eluent reservoir, silica 60…

  • SYNTHWARE short chrmoatography column with a lower standard taper 24/40 inner joint with a sealed in drip tip and a hose connection. Designed to perform seperations using a vacuum source. All sizes have a fritted disc to support column packing.

  • …general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top spherical socket joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Joint: SJ 35/20 Note: since the chromatography column is used with positive…

  • Samples that are not readily soluble in the mobile phase, are adsorbed onto a solid phase adsorbent (e.g silica). The adsorbent with the added sample is then placed into an empty solid loader tube, and introduced into the Reveleris® flash chromatography instrument.

  • Samples that are not readily soluble in the mobile phase, are adsorbed onto a solid phase adsorbent (e.g silica or celite). The adsorbent with the added sample is then placed into an empty solid loader tube, and introduced into the Reveleris® flash chromatography instrument.

  • FlashPure cartridges are packed with high quality silica designed to help maximize performance on any flash purification instrument. Large selection of cartridge sizes Luer lock inlet and Luer slip outlet Non-RFID suitable on any system Standard FlashPure cartridges use a…

  • General purpose column having a PTFE stopcock and a top Rodaviss® outer joint. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC CHEMISTRY 43, 2923 [1978], and covered in U.S. Patent Number…

  • …particles. FlashPure Select silica cartridges are filled with 15 µm spherical particles for the ultimate and unmatched performance in a flash chromatography cartridge. FlashPure Select funcationalized silica cartridges such as C18, Amino and Diol are packed with 30 µm spherical silica.

  • FlashPure ID cartridges are packed with high quality silica designed to help maximize performance on BUCHI Reveleris chromatography systems. Large selection of cartridge sizes Luer lock inlet Luer slip outlet RFID tag tracks cartridge use and history Standard FlashPure ID…

  • SYNTHWARE chromatography reservoirs with standard taper 24/40 joints or spherical 35/20 joints. Designed for use with flash chromatography.

  • FlashPure EcoFlex cartridges are packed with quality silica designed to help maximize cost and performance on any flash purification instrument. Large selection of cartridge sizes Several stationary phases available Luer lock inlet and Luer slip outlet Non-RFID suitable on any…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.