Flash Chromatography Column

Compare Tool

Select up to 3 products

Flash Chromatography Column
1 - 32 of 55
Sort
View
Show

GFS

  • …general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Top Joint: ST 24/40. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with…

  • …Excellent for purification of a wide range of synthetic and natural compounds Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • FlashPure EcoFlex cartridges are packed with quality silica designed to help maximize cost and performance on any flash purification instrument. Large selection of cartridge sizes Several stationary phases available Luer lock inlet and Luer slip outlet Non-RFID suitable on any…

  • …phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography

  • … Pure C-810 / C-815 Flash More purification in a very convenient way Pure C-810 / C-815 Flash are two advanced and powerful flash systems designed to get more purification in less space, as they belong to the smallest chromatography systems on the market be operated…

  • …phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back…

  • …purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Top Joint: ST 24/40 Note: since the chromatography column is…

  • …peak shapes with polar and basic compound—ideal for carbohydrates Make connections to flash chromatography instruments quick, easy, and secure with Luer-lok connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top standard taper outer joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully minimized to…

  • FlashPure cartridges are packed with high quality silica designed to help maximize performance on any flash purification instrument. Large selection of cartridge sizes Luer lock inlet and Luer slip outlet Non-RFID suitable on any system Standard FlashPure cartridges use a…

  • Flash glass columns

    MACHEREY-NAGEL

    Glass columns and kits for low pressure flash chromatography Economic low-tech method for the synthesis laboratory Suited for the separation of compounds up to gram levels No expensive equipment required MN flash chromatography kits include a glass column, eluent reservoir, silica 60…

  • …general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top spherical socket joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Joint: SJ 35/20 Note: since the chromatography column is used with positive…

  • Ideal for first stage clean-up columns post synthesis using a vacuum manifold Excellent for purification of a wide range of synthetic and natural compounds Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or…

  • Samples that are not readily soluble in the mobile phase, are adsorbed onto a solid phase adsorbent (e.g silica or celite). The adsorbent with the added sample is then placed into an empty solid loader tube, and introduced into the Reveleris® flash chromatography instrument.

  • …absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and…

  • SYNTHWARE general purpose chromatography column with heavy wall design. With reinforced beaded top. Supplied with a PTFE stopcock. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with positive air…

  • SYNTHWARE short chrmoatography column with a lower standard taper 24/40 inner joint with a sealed in drip tip and a hose connection. Designed to perform seperations using a vacuum source. All sizes have a fritted disc to support column packing.

  • …make a pressure-tight, O-Ring compression seal with glass stem on reservoir & flow adapter. Bushing replaces joint clamp. Column & reservoir, only, are Epoxy Coated. Column available with or without Por.B (70-100m) fritted disc sealed in. Order each item separately for complete system.

  • …absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g3 in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and…

  • General purpose column having a PTFE stopcock, reservoir of the listed capacity and a top spherical socket joint. Glass wool (not supplied) is used to support the column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by…

  • … Excellent for purification of a wide range of synthetic and natural compounds Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • Samples that are not readily soluble in the mobile phase, are adsorbed onto a solid phase adsorbent (e.g silica). The adsorbent with the added sample is then placed into an empty solid loader tube, and introduced into the Reveleris® flash chromatography instrument.

  • General purpose column has a PTFE stopcock and a top outer joint. Glass wool (not supplied) is used to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia…

  • …particles. FlashPure Select silica cartridges are filled with 15 µm spherical particles for the ultimate and unmatched performance in a flash chromatography cartridge. FlashPure Select funcationalized silica cartridges such as C18, Amino and Diol are packed with 30 µm spherical silica.

  • Similar to CG-1196 but with a COARSE porosity sealed in fritted disc to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia University in JOURNAL OF ORGANIC…

  • FlashPure ID cartridges are packed with high quality silica designed to help maximize performance on BUCHI Reveleris chromatography systems. Large selection of cartridge sizes Luer lock inlet Luer slip outlet RFID tag tracks cartridge use and history Standard FlashPure ID…

  • …purpose column having a PTFE stopcock, reservoir of the listed capacity and a top standard taper outer joint. Glass wool (not supplied) is used to support the column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described…

  • …reverse phase flash capabilities Has a pore size of 60Å and a carbon loading of ≈18% Easily connect to flash chromatography system using the Luer-slip connection. Use columns on a rack or stand using gravity flow or with vacuum processing stations. All columns are made from…

  • Columns are prefitted with a bottom frit Use dry loading columns with bulk sorbents to quickly and easily apply to flash chromatography system. Attach dry loading columns directly to the main flash columns to suit majority of reaction scales. Columns feature Luer-lok® inlet and Luer-slip…

  • …TELOS flash column installation Luer connections ensure leak-free chromatography Flash column holders accommodate any combinations of TELOS dry loading columns (4 to 40 g) and TELOS flash columns (4 to 330 g). Easily increase the capacity by installing two 120 g columns in series. Column

  • … NH2 shows better peak shapes with polar and basic compound—ideal for carbohydrates Make connections to flash chromatography instruments quick and easy with Luer connectors. Columns are made of polypropylene and have pressure ratings to support common flash chromatography back pressures.

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a reinforced beaded top. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully minimized to prevent…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.