Filter Funnel 0.45
-
Filter Funnel With Dark Membrane
Thermo Scientific Nalgene…of membrane for microbiological analysis. Membrane diameter is 47 mm and the pore size is 0.45 µm. Polypropylene housing with polystyrene collar. Supplied with six sterile funnel adapters, designed to fit a No. 8 rubber stopper. Each funnel is packaged in an easy-open bag for convenience.
-
…Microfil funnels that comes with the 0.45 mum pore size, black gridded S pak filter system eliminate the need for washing and sterilizing after each test thus making the equipment handling easier and efficient for general microbiological analysis. The push-fit design of the Microfil funnels seals…
-
…Microfil funnels that comes with the 0.45 mum pore size, black gridded S pak filter system eliminate the need for washing and sterilizing after each test thus making the equipment handling easier and efficient for general microbiological analysis. The push-fit design of the Microfil funnels seals…
-
Analytical Test Filter Funnels
Thermo Scientific NalgeneUse these economical sterile disposable filter funnels to perform microbiological QC testing and analysis of water, food/beverage, raw material and finished product. The squeeze and twist funnel is easy to remove for retrieval of the CN membrane. Economical, disposable and sterile …
-
Analytical Funnels
GVS Filter TechnologyReady-to-use 100 mL filtration units with removable cellulose nitrate membrane and culturing devices. Saves up to 50% in time with no flaming and sterilization required Minimizes the risk of cross contamination Easy release of membrane
-
…100 mL Microfil funnels that comes with the 0.45 mum pore size, black gridded EZ pak filter system eliminate the need for washing and sterilizing after each test thus making the equipment handling easier and efficient to trap bacteria. The push-fit design of the Microfil funnels seals tightly to…
-
…at once, directly into HPLC vials. Millex Filters for the Samplicity G2 System provide adaptor funnels and Millex 33 mm filters. Samplicity G2 System has lower ergonomic impact than manual syringe filtration. Available in 0.20 µm and 0.45 µm pore sizes with hydrophilic PTFE, Durapore…
-
…Milliflex filter units combine a funnel and a Durapore membrane (Polyvinyliden di-Fluoride (PVDF)) membrane filter in one device. The sealed integral membrane filter eliminates membrane manipulation and handling. This improves testing reliability. For sterility testing application, Milliflex funnels…
-
…system is a fast and reliable alternative for the detection of microorganisms. The kit includes fluorescent reagent and Milliflex(R) HAWG 100 mL funnels (0.45 mum membrane, white gridded). Synonyms: Fluorescence-based rapid detection system Application: The Milliflex(R) Quantum Universal Kit…
-
…sample throughout filtration, and a 360 rim prevents forceps from accidentally touching the membrane filtration area during membrane transfer. The funnel material is clear and transparent and allows for visualizing the end of the filtration from any angle. The blue units allow to either transfer the…
-
Analytical Filter Units
Thermo Scientific Nalgene…with polystyrene reservoir Filter units are excellent for microbial analysis, sterility testing and water quality or environmental testing. Model 1208M78 has a 0.2 µm white membrane and is ideal for sterility testing. Model 1208M79 is has a 0.45 µm white membrane with a grey…
-
…samples at once, directly into HPLC vials. Millex Filters for the Samplicity G2 System provide adaptor funnels and Millex 33 mm filters. Samplicity G2 System has lower ergonomic impact than manual syringe filtration. Available in 0.20 µm and 0.45 µm pore sizes with Durapore PVDF, Millipore…
-
…sterilized filter unit that combines a 100mL funnel and a membrane filter in a single device offering a complete solution for bioburden testing. The filter unit is made of polypropylene, SAN and the membrane is made of black gridded, 51mm diameter mixed cellulose esters (MCE) with 0.45mum pore size.…
-
150 mL Tube Top Filter
Corning…highest protein yields. Eliminates unneccesary transfer and minimizes contamination by filtering directly into a 50-mL centrifuge tube. The polypropylene centrifuge tube is supplied with an individually wrapped cap for storage. Funnel size is 150 mL. Case of 12 includes two centrifuge tube stands.
-
…sterilized filter unit that combines a 100mL funnel and a membrane filter in a single device offering a complete solution for bioburden testing. The filter unit is made of Polypropylene, SAN and the membrane is made of white gridded, 51mm diameter mixed cellulose esters (MCE) with 0.45mum pore size.…
-
…sterilized filter unit that combines a 250mL funnel and a membrane filter in a single device offering a complete solution for bioburden testing. The filter unit is made of polypropylene, SAN and the membrane is made of white gridded, 51mm diameter mixed cellulose esters (MCE) with 0.45mum pore size.…
-
…sterilized filter unit that combines a 100mL funnel and a membrane filter in a single device offering a complete solution for bioburden testing. The filter unit is made of polypropylene, SAN and the membrane is made of white plain, 51mm diameter polyvinylidene difluoride (Durapore®) with 0.45mum…
-
…funnel and a membrane filter in a single device offering a complete solution for bioburden testing and an empty media plate (cassette) for liquid media. The filter unit is made of Polypropylene, SAN and the membrane is made of white gridded, 51mm diameter mixed cellulose esters (MCE) with 0.45mum…
-
Sterile Bottle-Top Filters
Corning…membranes. Pores sizes of 0.2 or 0.45 µm are available for CA and CN membranes. NY and PES are available only in 0.2 µm pore size. Filters are color-coded by membrane type for fast and easy identification. Prefilters are included. Polystyrene funnels have either 33 or 45-mm polyethylene…
-
…samples at once, directly into HPLC vials. Millex Filters for the Samplicity G2 System provide adaptor funnels and Millex 33 mm filters. Samplicity G2 System has lower ergonomic impact than manual syringe filtration. Available in 0.20 µm and 0.45 µm pore sizes with Durapore PVDF, Millipore…
-
…samples at once, directly into HPLC vials. Millex Filters for the Samplicity G2 System provide adaptor funnels and Millex 33 mm filters. Samplicity G2 System has lower ergonomic impact than manual syringe filtration. Available in 0.20 µm and 0.45 µm pore sizes with Durapore PVDF, Millipore…
-
Autofil® SS Bottle-Top Vacuum Filters
Foxx Life Sciences…Flow Foxx Velocity 0.2um PES membrane. Perfect for filtering FBS and other viscous solutions. Our membrane is low protein binding and surfactant-free. Autofil SS is available in 250ml, 500ml, and 1000ml complete units or funnel only bottle-top filters. All units are sterile and manufactured from USP…
-
Autofil® PP Bottle-Top Filters for Solvent Filtration
Foxx Life Sciences…Sciences' Autofil® PP bottle-top filters for solvent filtration are a revolutionary new way to purify solvents for analytical applications to obtain sterilized or purified extracts. Foxx has developed the world's first single piece polypropylene funnel, designed to withstand harsh…
-
…mL to 1 L, with choice of membrane filter material: Cellulose Acetate (CA) with 0.22 or 0.45 µm pore size; Cellulose Nitrate (CN) or Nylon (NY) with 0.2 µm pore size; and Polyethersulfone (PES) with 0.22 µm pore size. Receiver bottle and funnel are of the same capacity except for…
-
Microbiological Monitors
GVS Filter TechnologyMicrobiological Monitor: The membrane is fixed to the unit. Available 47 mm or 56 mm Features and Benefits: Rapid testing: Pre-sterilized reduces testing time by up to 70% No flaming required: Combined filtration unit minimizes the risk of cross-contamination Filtration…
-
MILLIFLEX OASIS® filtration unit
MilliporeSigma…100 mL funnel is a ready-to-use, sterile filter unit that combine a funnel and a gridded membrane filter in a single device offering a complete solution for bioburden testing. The filter unit is made of Styrene butadiene copolymer and the membrane is made of mixed cellulose esters with 0.45 mum pore…
-
Autofil™ Bottle-Top Filtration System
Foxx Life Sciences…and 0.45 µm (clarification grade) PES membranes. The complete system is composed of a polystyrene filter funnel and receiver bottle, a SECUREgrasp cap, and a vacuum hose adapter. Systems with 15 mL and 50 mL polypropylene centrifuge tubes are also available. Filtration funnels are…
-
DURAN® TILT Bottles
DWK Life Sciences (Duran)… Filter Funnels Designed for sterilization or clarification of aqueous cell culture media. Supplied as a filter funnel only unit for use with the Duran TILT (with GL 45 thread adaptor) or 45 mm media bottles. Comes in three different asymmetric pore sizes (0.1 um, 0.2 um, 0.45 um). Raised…
-
Autofil® 2 Bottle Top Filtration Device Full Assembly
Foxx Life Sciences…and 0.45µm PES membranes. Perfect for filtering FBS and other viscous solutions. Our membrane is low protein binding and surfactant-free. Autofil® 2 is available in 250mL, 500mL, and 1000mL complete units with the NEW EZlabpure™ media bottle or funnel only bottle-top filters.…
