Female Luer

Compare Tool

Select up to 3 products

Female Luer
33 - 64 of 114
Sort
View
Show
  • … Membrane: Binder-free Glass Microfiber Housing: medical grade, virgin polypropylene     Connections: enhanced female Luer-Lok™ inlet, male Luer slip outlet       Max. operating temperature: 110°C Max. operating pressure: 30mm - 90psi   …

  • Blood collection / infusion sets with female luer attached are used for routine venipunctures and infusion applications.

  • …made of Ethyl Vinyl Acetate (EVA) and are provided in a hanging configuration for greater functionality. A male MPC connector and male and female luers are connected to the bag by C-Flex clear tubing. EVA is a copolymer of ethylene and vinyl acetate, and is recognized for its exceptional flexibility…

  • …manifold is used under closed conditions and must be vented to the atmosphere without breaking the vacuum connection. The 3-way valve vent is female luer slip and accepts a disposable syringe filter(13JP020AN) or KS13 holder with PTFE filter(J020A013A) to maintain sterility. The manifold outlet is…

  • Luer-to-Luer Adapters

    Cadence Science

    …plastic male luer lock adapters. Uniquely designed to facilitate easy cleaning and maintenance. Male Luer Lock (MLL) – male luer slip with a threaded sheath for a secure fitting to a female luer lock. Male Luer (ML) – male luer slip that fits with a female luer. For…

  • MAWP025A0

    MilliporeSigma

    3-piece polystyrene monitor with 16 mm center ring. Female Luer slip vacuum connection. Requires tubing adapter (XX62 000 05). This monitor is also available without membranes. With 25 mm filter

  • … Available in 10L and 20L sizes Film type: EVA Port 1:  Female MPC connector with 1/4" barb + plug, Slide clamp Port 2:  Male MPC connector with 1/4" barb + cap, Slide clamp Port 3:  Vinyl cap, Swabbable valve, Female luer with barb

  • …improved patient outcomes. It offers the security of a threaded, locking luer connection, replacing a luer-slip device. It is latex-free and compatible with a female luer connection or needleless IV site designed for luer lock access. *As of April 2019, 364902 will be now be packaged in 6-unit…

  • …Effective Filtration Area (cm2): 1.09 Pore Size (µm): 0.45 µm Holdup Volume (µl): Sample Volume (mL): Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50°C Maximum Operating Pressure: 87 psi (6.0 bar) at 20 °C Typical Applications: …

  • …Effective Filtration Area (cm2): 5.39 Pore Size (µm): 0.22 µm Holdup Volume (µl): Sample Volume (mL): Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50 °C Maximum Operating Pressure: 6 bar Typical Applications: High particulate…

  • …membrane materials, offered in 0.2µm or 0.45µm pore sizes. The filter membranes are reinforced with polypropylene housing with a female Luer-lok inlet and a male Luer slip outlet. All materials comply with USP Class VI Standards. PES - high asymmetric PES membrane, high flow rate, low extractable…

  • SLGVR33RB

    MilliporeSigma

    A 33 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic PVDF membrane. Color Code: Yellow Connections, Inlet/Outlet: Female Luer-Lok/Male Luer slip Maximum Inlet Pressure, bar (psi): 10 (145) Sterilization: Gamma irradiation

  • …size, membrane, and housing polymer. Units are sterilized by EtO gas, except PES and Nylon are Gamma Irradiated. Dismic models have female luer-lock inlet and male luer slip outlet. These units are individually blister packed. Labodisc-50 models are in-line units with 7-13.5 mm hose barb inlet and…

  • SLHAR33SS

    MilliporeSigma

    A 33 mm diameter sterile syringe filter with a 0.45 µm pore size Mixed Cellulose Esters membrane. Color Code: Blue Connections, Inlet/Outlet: Female Luer-Lok/Male Luer slip Maximum Inlet Pressure, bar (psi): 10 (145) Sterilization: Ethylene oxide

  • …polymer. Polypropylene can be autoclaved, acrylic can not. For pre-sterilized units see our sterile listing. Dismic models have female luer-lock inlet and male luer slip outlet. Labodisc-50 models are in-line units with 7-13.5 mm hose barb inlet and outlet connections and an inlet vent. …

  • …accepts a 40/35 female joint to adapt to microanalysis units. The valve is PVC with a PTFE stopcock. The 3-way PVC valve with PTFE stopcock allows the manifold to be vented to atmosphere when used under closed conditions without breaking the vacuum connection. The valves luer slip vent port accepts…

  • SLVVR33RS

    MilliporeSigma

    …a 0.1 µm pore size hydrophilic PVDF membrane. Lowest protein binding sterilization/clarification of biological solutions Connections, Inlet/Outlet: Female Luer-Lok/Male Luer slip Color Code: Yellow Sterilization: Gamma irradiation Maximum Operating Temperature, °C: 45

  • SLGPM33RS

    MilliporeSigma

    A 33 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic Polyethersulfone (PES) membrane. Color Code: Green Connections, Inlet/Outlet: Female Luer-Lok/Male Luer slip Maximum Inlet Pressure, bar (psi): 10 (145) Sterilization: Gamma irradiation

  • …samples high in particulates. Membrane: Hydrophilic Polypropylene Housing: medical grade, virgin polypropylene Connections: enhanced female Luer-Lok inlet, male slip outlet Max. operating temperature: 110°C Max. operating pressure: 17mm - 115psi, 30mm - 90psi Retention…

  • Syringe Type Membrane Filters

    Thermo Scientific Nalgene

    Membrane filters enclosed in plastic housing with female Luer-Lok fitting on inlet for attachment to standard Luer-Lok-tip syringes. Male Luer-slip tip on outlet accepts standard needles. Usable for pressure or vacuum applications. Effective filtration area is 3.8 cm 2 . Offered in a choice of…

  • …1/4"-28 nylon unions; 2 x 1/4"-28 PP luer locks female; 1 x 1/4"-28 PP luer locks male; 1 x 1/4"-28 PP luer tip male CHROMABOND® Flash Stand Alone Kit consists of: 1 x 1/4"-28 PP luer lock female; 1 x 1/4"-28 PP luer lock male; 2 x 1/8" ETFE ferrules; 2 x…

  • Syringe Filters

    Celltreat Scientific

    … The filters are heat sealed in the housing, providing a reliable seal without the use of glues or sealants. All filters are designed with Female Luer-Lock inlets and Male Luer-Lock outlets. Gamma sterilized, non-pyrogenic and RNA/DNA-Free. Tips on choosing membrane: PVDF…

  • Target HPLC Syringe Filters

    National Scientific

    Non-sterile, sample prep membrane filters 7 membrane types Female Luer-Lock inlet, male Luer-slip outlet Solvent resistant polypropylene housings PES, GMF, Polypropylene and Cellulose Acetate membranes are certified for Ion Chromatography The polypropylene housings with all…

  • …Filtration Area (cm2): 1.09 Pore Size (µm): 0.45 µm Holdup Volume (µl): <25 Sample Volume (mL): <10 Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50°C Maximum Operating Pressure: 87 psi (6.0 bar) at 20 °C Typical Applications: …

  • …Filtration Area (cm2): 1.09 Pore Size (µm): 0.22 µm Holdup Volume (µl): <25 Sample Volume (mL): <10 Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50°C Maximum Operating Pressure: 87 psi (6.0 bar) at 20 °C Typical Applications: …

  • …Effective Filtration Area (cm2): 5.39 Pore Size (µm): 0.45 µm Holdup Volume (µl): Sample Volume (mL): Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50 °C Maximum Operating Pressure: 6 bar Typical Applications High particulate…

  • …Filtration Area (cm2): 4.08 Pore Size (µm): 0.45 µm Holdup Volume (µl): <100 Sample Volume (mL): <100 Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50 °C Maximum Operating Pressure: 87 psi (6.0 bar) at 20 °C Typical Applications: …

  • …Filtration Area (cm2): 4.08 Pore Size (µm):0.22 µm Holdup Volume (µl): <100 Sample Volume (mL): <100 Inlet Connection: Female luer lock Outlet Connection: Male luer slip Maximum Operating Temperature: 50 °C Maximum Operating Pressure: 87 psi (6.0 bar) at 20 °C Typical Applications: …

  • Metallocene Collection Bags

    Corning cellgro

    … Film type: Metallocene Port 1:  24" length 1/4" I.D. x 3/8" O.D. PCMGS tubing, female Luer with 1/4" barb, cap, slide clamp Port 2:  24" length 1/4" I.D. x 3/8" O.D. PCMGS tubing, male Luer with 1/4" barb, cap, slide clamp

  • …other instrument analyses. Connections, Inlet/Outlet: Female Luer-Lok/Male Luer slip Filter Code: HP Fitting Inlet: Female Luer-Lok® Fitting Outlet: Male Luer slip Housing Material: Polypropylene (PP) Color…

  • High quality anhydrous sodium sulfate Approximately 2 grams prepackaged in a convenient capped cartridge with both male and female luer ends for easy connection to a variety of devices or equipment The adsorbent is fully activated and ready to use for removal of excess water from organic…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.