Extraction Thimble Glass

Compare Tool

Select up to 3 products

Extraction Thimble Glass
1 - 22 of 22
Sort
View
Show
  • All glass extraction thimble permits viewing during extraction process and subsequent weighing. Sizes correspond to CG-1368 or CG-1369 extractor. Available in coarse or extra coarse porosity.

  • Extraction Thimble, All Glass Available in multiple sizes (small, medium, large) Porosity: Available in Extra Course and Course All glass extraction thimble permits viewing extraction process and subsequent weighing.

  • …most Soxhlet extraction units. They are well-suited to pollution monitoring when analysis of hot and acidic gases is required. Extraction thimbles in glass, quartz, or cellulose are available from Cytiva (formerly GE Healthcare Life Sciences) business. Glass Soxhlet extraction thimble applications…

  • Glass Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can withstand temperatures up to 500°C making them ideal for high temperature extractions, dust monitoring, or smoke stack gas sampling. They are acid resistant(except hydrofluoric). Thimbles have…

  • Quartz thimbles are used for emission testing in high temperature environments. They can also be used for testing acidic gases which are not compatible with micro-glass fiber thimbles. Quartz meets the highest purity requirements due to the lowest possible heavy metal content.

  • With an ACE fritted disc sealed in. Can be used in any standard Soxhlet extraction apparatus. The sizes below correspond to the size specifications of extraction bodies and will fit those units. Available in porosities A, B, C, D and E. All porosities of a given size are priced the same. Height…

  • … High-purity glass binderless microfiber Common Cellulose Thimble applications include fat determination of meat and dairy products, determination of PCB in fish products, determination of free fats in food products, determination of pesticide residues in food products, extraction of plasticizers…

  • Soxhlet type extraction apparatus used for continuous extraction of solids with a suitable solvent. Extractor uses paper or CG-1372 glass thimbles. Condenser has an enlarged uptake tube to improve condensing capacity. Complete apparatus consists of an Allihn condenser, extractor and flat bottom…

  • …in solid wastes Extraction thimbles in glass, quartz, or cellulose are available from Cytiva (formerly GE Healthcare Life Sciences) business. Cytiva (formerly GE Healthcare Life Sciences) standard glass Soxhlet thimble range Whatman standard glass extraction thimbles are available in a range…

  • …Taper joints for quick, secure connections. Extraction thimbles, paper filters or glass wool are used to support the sample. The siphon tube on the extractor is protected by the vapor sidearm tube. Small with 50 mL flask (4406K22) Extraction chamber 29 mm i.d. x 110 mm usable depth …

  • …chemical applications. Improved design permits greater condensing capacity. Condenser approximately 139mm jacket length. Joint between condenser and extractor is 24/25. Flask joint is 14/20. Designed to accommodate paper thimble, size 10 x 50 mm. Flask is 30mL capacity. Hose connections are size B.

  • …an open drain of at least 3/4" IPS; and 6-foot, 3-wire cord with plug. Includes 6 support stirrups, 12 borosilicate glass 100 ml beakers, 6 alundum extraction thimbles, 6 heat covers, 6 cork gaskets, 6 beaker rings, 6 upper condenser gaskets, 9 sample tubes and 9 borosilicate glass reclaiming tubes.

  • glass binderless microfiber Common Glass Microfiber Thimble material applications include gravimetric methods for hot environments, gravimetric methods for acidic gasses, and extraction methods common to biochemical analysis. Common Thimble applications include soxhlet extraction, air…

  • glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles. These thimbles

  • 603G Glass fiber thimble with inorganic binder Designed to fit most commercially available Soxhlet extractors No binders are added Available in a range of sizes and wall thicknesses to suit your application Thimbles of type 603G are made from borosilicate glass fibers with…

  • Thimbles of type 603 are made from high-quality cellulose and 603 g thimbles are made from borosilicate glass fibers with an inorganic binder. For all automated extraction apparatus in common use, Whatman offers thimbles whose dimensions are matched exactly to those of the thimble holders to ensure…

  • …quartz thimbles fromCytiva (formerly GE Healthcare Life Sciences)support accurate, reproducible emission testing by providing low extractable levels and temperature resistance up to 800°C. Cytiva (formerly GE Healthcare Life Sciences) business also offers glass and cellulose extraction thimbles.

  • Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    …Extractor has a Standard Taper outer joint at the top for connection to the condenser and a Standard Taper inner joint at the bottom for connection to the flat bottom boiling flask. Soxhlet extraction apparatus uses cellulose, glass microfiber or fritted glass extraction thimbles (not supplied).

  • Soxhlet/Dean Stark Extraction Apparatus

    DWK Life Sciences (Kimble)

    …desiccation prior to Soxhlet extraction Loss of analytes and sample contamination are avoided Uses a 586500-0233 fritted glass extraction thimble, not supplied PTFE stopcock plug is 821001-0002 Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I…

  • Extra Large Soxhlet Extraction Apparatus

    Wilmad-LabGlass - SP Scienceware

    …the siphon tube. The extractor has a standard taper outer joint at the top for connection to the condenser and a standard taper inner joint at the bottom for connection to the flask. *Soxhlet extraction apparatus uses cellulose, glass microfiber or fritted glass extraction thimbles (not supplied).

  • Micro size Soxhlet extractor for use with 10 x 50mm paper or glass thimbles. Extractor body has a 19/22 top inner joint and a 14/20 lower inner joint. Complete apparatus consists of the extractor body, condenser, and 25mL round bottom flask. Glass thimbles must be ordered separately.

  • Glass thimbles are used to sample dust particles and aerosols from gaseous streams in the analytical registration of environmental pollution and for Soxhlet extractions requiring solvents too aggressive for the cellulose thimbles.

Compare Tool

Select up to 3 products

Please Log In