Extraction Thimble Glass
-
Extraction Thimbles, Glass
Ace GlassWith an ACE fritted disc sealed in. Can be used in any standard Soxhlet extraction apparatus. The sizes below correspond to the size specifications of extraction bodies and will fit those units. Available in porosities A, B, C, D and E. All porosities of a given size are priced the same. Height…
-
…glass binderless microfiber Common Glass Microfiber Thimble material applications include gravimetric methods for hot environments, gravimetric methods for acidic gasses, and extraction methods common to biochemical analysis. Common Thimble applications include soxhlet extraction, air…
-
… High-purity glass binderless microfiber Common Cellulose Thimble applications include fat determination of meat and dairy products, determination of PCB in fish products, determination of free fats in food products, determination of pesticide residues in food products, extraction of plasticizers…
-
Glass Extraction Thimble Filters
Advantec MFS… Glass Fiber thimbles are made of pure borosilicate glass microfibers. These binder-free filters can withstand temperatures up to 500°C making them ideal for high temperature extractions, dust monitoring, or smoke stack gas sampling. They are acid resistant(except hydrofluoric). Thimbles have…
-
SYNTHWARE Glass Extraction Thimbles
Kemtech AmericaExtraction Thimble, All Glass Available in multiple sizes (small, medium, large) Porosity: Available in Extra Course and Course All glass extraction thimble permits viewing extraction process and subsequent weighing.
-
Glass Extraction Thimbles
ChemglassAll glass extraction thimble permits viewing during extraction process and subsequent weighing. Sizes correspond to CG-1368 or CG-1369 extractor. Available in coarse or extra coarse porosity.
-
Soxhlet Extraction Apparatus
SP Wilmad-LabGlass…Extractor has a Standard Taper outer joint at the top for connection to the condenser and a Standard Taper inner joint at the bottom for connection to the flat bottom boiling flask. Soxhlet extraction apparatus uses cellulose, glass microfiber or fritted glass extraction thimbles (not supplied).
-
Soxhlet/Dean Stark Extraction Apparatus
DWK Life Sciences (Kimble)…desiccation prior to Soxhlet extraction Loss of analytes and sample contamination are avoided Uses a 586500-0233 fritted glass extraction thimble, not supplied PTFE stopcock plug is 821001-0002 Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I…
-
Extra Large Soxhlet Extraction Apparatus
SP Wilmad-LabGlass…the siphon tube. The extractor has a standard taper outer joint at the top for connection to the condenser and a standard taper inner joint at the bottom for connection to the flask. *Soxhlet extraction apparatus uses cellulose, glass microfiber or fritted glass extraction thimbles (not supplied).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Extraction Apparatus, Soxhlet, Micro
ChemglassMicro size Soxhlet extractor for use with 10 x 50mm paper or glass thimbles. Extractor body has a 19/22 top inner joint and a 14/20 lower inner joint. Complete apparatus consists of the extractor body, condenser, and 25mL round bottom flask. Glass thimbles must be ordered separately.
-
Extraction Apparatus, Soxhlet
ChemglassSoxhlet type extraction apparatus used for continuous extraction of solids with a suitable solvent. Extractor uses paper or CG-1372 glass thimbles. Condenser has an enlarged uptake tube to improve condensing capacity. Complete apparatus consists of an Allihn condenser, extractor and flat bottom…
-
…Taper joints for quick, secure connections. Extraction thimbles, paper filters or glass wool are used to support the sample. The siphon tube on the extractor is protected by the vapor sidearm tube. Small with 50 mL flask (4406K22) Extraction chamber 29 mm i.d. x 110 mm usable depth …
-
Micro-Glass Fiber Thimbles, ET/MG160
Ahlstrom-MunksjoGlass thimbles are used to sample dust particles and aerosols from gaseous streams in the analytical registration of environmental pollution and for Soxhlet extractions requiring solvents too aggressive for the cellulose thimbles.
-
Micro-Quartz Fiber Thimbles, ET/MK360
Ahlstrom-MunksjoQuartz thimbles are used for emission testing in high temperature environments. They can also be used for testing acidic gases which are not compatible with micro-glass fiber thimbles. Quartz meets the highest purity requirements due to the lowest possible heavy metal content.
-
Goldfisch Fat Extractor, 6-Unit
Labconco…an open drain of at least 3/4" IPS; and 6-foot, 3-wire cord with plug. Includes 6 support stirrups, 12 borosilicate glass 100 ml beakers, 6 alundum extraction thimbles, 6 heat covers, 6 cork gaskets, 6 beaker rings, 6 upper condenser gaskets, 9 sample tubes and 9 borosilicate glass reclaiming tubes.
-
Micro Soxhlet, Improved Design
Ace Glass…chemical applications. Improved design permits greater condensing capacity. Condenser approximately 139mm jacket length. Joint between condenser and extractor is 24/25. Flask joint is 14/20. Designed to accommodate paper thimble, size 10 x 50 mm. Flask is 30mL capacity. Hose connections are size B.