Extraction Manifold

Compare Tool

Select up to 3 products

Extraction Manifold
1 - 32 of 60
Sort
View
Show
  • TELOS® Sample Processing Manifolds

    Kinesis

    …tank allows a clear view of the extraction process Control sample flow individually using the optional PTFE stopcocks Separate waste container prevents tank contamination Use vacuum manifolds for SPE sample preparation, filtration, and elution. Manifolds come complete with everything you…

  • Vaccuum Manifolds And Accessories

    Agilent Technologies

    manifolds and accessories complement the quality of AccuBOND II sorbents. Flexible configurations and availability as complete assemblies or individual components mean that the user has the necessary capability at any stage from method development to high throughput operation. Vacuum manifold

  • Base assembly, for 96-well plate manifold

    Agilent Technologies

    The base accomodates lids that hold either a user-defined selection of flexible cartridges, or fixed format 96-well plates with each well loaded with the same sorbent.

  • Diskcover-47 Extraction Disk Holder

    Restek

    Compatible with most vacuum manifold systems that accept 1/8-inch male luer fittings Sample can be automatically introduced via 1/8-inch PTFE tubing or from the optional Diskcover-47 reservoir

  • Glass Chamber with 24 Positions

    PerkinElmer

    Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction

  • 47mm Phase/Fraction Collector Filtration Assemblies

    Advantec MFS

    …samples can be collected.   Two models available. The P/FC1 is supported on a manifold or standard 1L flask by a No.8 silicone stopper. The P/FC2 couples to a 40/35 male taper on extraction manifold or 1L flask. The anodized aluminum clamp secures the 47mm membrane between the 300mL…

  • Extraction System

    Avantor - J.T.Baker®

    …vials. Samples are aspirated through disposable, prepacked extraction columns which selectively remove compounds from solution. Extracted compounds are then eluted into tubes positioned in a removable rack placed inside the manifold. Collected eluates are either used directly or evaporated and…

  • Visiprep™ SPE Vacuum Manifold, Standard, 24-Port Model

    MilliporeSigma

    …reproducible extractions. Unlike other vacuum manifolds, the Visiprep system contains a patented valve system that allows for precise flow control through each SPE tube via rotating, independent, screw-type valves situated in each port within the manifold cover. Visiprep vacuum manifolds allow you…

  • Stainless Steel Extraction Manifold

    Advantec MFS

    …the manifold is used under closed conditions and must be vented to the atmosphere without breaking the vacuum connection. The 3-way valve vent is female luer slip and accepts a disposable syringe filter(13JP020AN) or KS13 holder with PTFE filter(J020A013A) to maintain sterility. The manifold outlet…

  • XenoSep® 1664A/B Solid Phase Extraction Filters

    Applied Separations

    …in EPA Method 1664B, Xenosep® High Performance (HP) Solid Phase Extraction (SPE) filters for EPA Method 1664A/B-HP are designed to provide high recovery and low blank values in Horizon® SPE-DEX® and SPE manifold EPA Method 1664A applications. Each SPE filter consists of glass fibers…

  • Resprep Sample Delivery System

    Restek

    …delivery system to transfer large volumes of low viscosity samples directly from a bottle to a solid phase extraction cartridge, or to a disk on a vacuum manifold system for extraction or cleanup. Each unit consists of six transfer lines with a stainless steel weight on one end and a color-coded…

  • Gas Manifold with Vacuum Chambers

    DWK Life Sciences (Kimble)

    An all-glass manifold for connecting inert gas and vacuum sources. Double vacuum gas manifold with vacuum chambers. Fabricated from 1/2" medium wall tubing Stopcocks are 4 mm bore glass with lower vacuum chamber and are spaced 85 mm apart Top right connection is for inert gas and…

  • DNA Fragment Extraction Kit

    IBI Scientific

    The Large DNA Fragment Extraction Kits are designed to recover large DNA fragements (> 8Kb) from an agarose gel. The Small DNA Fragment Extraction Kits are design to recover or concentrate small DNA fragments (50-200bp) from an agarose gel, PCR, or any other enzymatic reaction. This method uses a…

  • illustra GFX 96 PCR Purification Kit

    GE Healthcare

    … Prepacked glass fiber matrix 96-well plates are validated for use with Macherey-Nagel NucleoVac 96 vacuum manifold. Avoids ethanol precipitations and hazardous organic extractions. Purified DNA is ready for use in most applications, including fluorescent sequencing, microarrays, labeling,…

  • Visiprep™ Large Volume Sampler for use with 3 or 6 mL SPE tubes (includes 4…

    MilliporeSigma

    …12mL, 20mL, or 60mL polypropylene SPE tubes. Simultaneous extraction of 12 samples on a 12-port Visiprep manifold requires four of these samplers. The other sampler has four tube adapters for 3mL or 6mL SPE tubes. To simultaneously extract 12 samples, three samplers are required. The samplers…

  • PVC Extraction Manifold

    Advantec MFS

    …this extraction manifold a great alternative to stainless steel. Polyvinylchloride(PVC) is resistant to acids. The tapered branch accepts a 40/35 female joint to adapt to microanalysis units. The valve is PVC with a PTFE stopcock. The 3-way PVC valve with PTFE stopcock allows the manifold to be…

  • 12 Port Vacuum Extraction Manifold Assy

    Agilent Technologies

  • 20 Port Vacuum Extraction Manifold Assy

    Agilent Technologies

  • Vacuum Manifold Accessories

    Agilent Technologies

  • CHROMABOND® vacuum manifold

    MACHEREY-NAGEL

    For simultaneous preparation of up to 12, 16 or 24 samples

  • CHROMABOND® MULTI 96 vacuum manifold

    MACHEREY-NAGEL

    …Alternatively, use of multi-channel pipettors facilitates a manual liquid transfer. Extraction is carried our using the CHROMABOND® MULTI 96 vacuum manifold. With the help of the control valve the vacuum of the manifold can be adjusted leading to an optimum flow rate through the CHROMABOND®…

  • Whatman MBS I Plastic Funnel

    GE Healthcare

    …time is reduced to a minimum. The design of the system, which consists of an electrical membrane dispenser, a funnel dispenser, and a vacuum manifold, leads to more reproducible results. The special sealing technique ensures easy handling and high integrity of the funnel and membrane during…

  • ValuSep® 1664A Solid Phase Extraction Filters

    Applied Separations

    ValuSep® Solid Phase Extraction (SPE) filters for EPA Method 1664A are designed to provide high recovery and low blank values in Horizon® SPE-DEX® and SPE manifold EPA Method 1664A applications. Each SPE filter consists of glass fibers which have been chemically modified so they retain…

  • Resprep 6-Port Disk Manifold Lid

    Restek

    Low-cost option for disk extraction; fits standard 3 3/4" x 7 1/2" glass vacuum chambers Doubles sample capacity—holds six disks, compared to standard 12-port manifolds, which only hold three Individual vacuum control for each port improves reproducibility Collection plate…

  • Disposable Liners for Visiprep DL Manifolds

    MilliporeSigma

    Material: PTFE Packaging: Pack of 100

  • Vacuum Manifold, Complete Set with 24 positions

    PerkinElmer

    Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction

  • Polypropylene needs with 12 Positions

    PerkinElmer

    Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction

  • Stainless Steel Needles with 12 Position

    PerkinElmer

    Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction

  • Stopcocks 12 with Positions

    PerkinElmer

    Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction

  • Stainless Steel Needles with 24 Position

    PerkinElmer

    Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction

  • Glass Chamber with 12 Positions

    PerkinElmer

    …laboratory vacuum pump.  Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction process and the sample flow. Waste and wash solvents are discarded and analytes are collected in sample tubes below the manifold completing the extraction.

  • Drying Attachment with 24 Positions

    PerkinElmer

    Manifolds accommodate either 12 or 24 cartridges; 1, 3, 6, 15 and 25 mL columns can be used. Manifolds are equipped with a vacuum port to connect a standard laboratory vacuum pump. Vacuum pulls the sample through the stationary phase, metered by the stopcocks, to control the speed of the extraction

Compare Tool

Select up to 3 products

Please Log In