Direct Reading Titrator

Compare Tool

Select up to 3 products

Direct Reading Titrator
1 - 32 of 35
Related Categories: Titration Kit | Total Hardness Test Kit
Sort
View
Show
  • This kit tests for Total Hardness by using the Direct Reading Titrator Method. All results are as CaCO3. Range/sensitivity is 0-200 ppm/4ppm CaCO3. Applications: Industrial Water Boiling and Cooling, Water and Wastewater # Tests (# Rgts): 50 at 200 ppm (3)

  • Applications: Industrial Water Boiling and Cooling This test kit measures for Chlorine or Bromine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl or Br.

  • This kit tests for Sodium Nitrite using the Direct Reading Titrator method. Applications: Industrial Water Boiling and Cooling, Water and Wastewater Range/sensitivity is 0-1000 ppm/20 ppm NaNO2

  • This kit tests for nitrite using the direct reading titrator method. Range/sensitivity is 0-1000 ppm/20 ppm NaNO2 Applications: Industrial Water Boiling and Cooling, Water and Wastewater

  • This kit tests for Chloride in fresh water samples using the Direct Reading Titrator method. Applications: Environmental Education, Aquarium and Fish Farming

  • Applications: Industrial Water Boiling and Cooling, Water and Wastewater This test kit measures for Chlorine Bleach using the Direct Reading Titrator method. Range/sensitivity is 00-10%/0.2% Cl.

  • Direct Reading Titrator For determining free carbon dioxide in water Range of 0 to 55 ppm CO2 in 1 ppm increments Employs APHA Method 406B with sodium hydroxide titrant. Sufficient for 50 tests at 50 ppm.

  • Direct Reading Titrator (9859K40 and K41) For determining high range chlorine in water Range of 0 to 200 ppm Cl2 in 4 ppm increments Sufficient for 50 tests at 200 ppm. Uses Iodometric reagent method.

  • LaMotte

    Direct Reading Titrator For determining QAC (quaternary ammonium compounds) in cooling waters and sanitizing solutions Range of 0 to 500 ppm QAC in 10 ppm increments Sufficient for 50 tests at 500 ppm 

  • Direct Reading Titrator Method (9859A70 and A71) For determining total (T) alkalinity in water Range of 0 to 200 ppm as CaCO3 in 4 ppm increments Employs APHA Method 403. Sufficient for 50 tests at 200 ppm. Direct Reading Titrator (9859B10) For determining phenolphthalein (P)…

  • Direct Reading Titrator (9860J75 and J76) For determining dissolved oxygen in natural and treated waters Employs azide modification of Winkler method Range from 0 to 10 ppm with 0.2 ppm sensitivity Sufficient for 50 tests at 10 ppm Ideal for daily monitoring or D.O. meter…

  • Direct Reading Titrator (9859X42 and X43) For determining total hardness of water Range 0 to 200 ppm as CaCO3 in 4 ppm increments Titrators may be refilled to test higher concentrations Sufficient for 50 tests at 200 ppm Direct Reading Titrator (9859X72 and X73) For…

  • Applications: Drinking Water, Industrial Water Boiling and Cooling, Water and Wastewater This Alkalinity Test Kits uses a Direct Reading Titrator with standard acid to the phenolphthalein (P) and/or total (T) alkalinity endpoint. Range and sensitivity is 0–200 ppm as CaCO3 in 4 ppm…

  • This Chlorine test kit measures for Chlorine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl. Applications: Drinking Water, Food and Beverage, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater # Tests (# Rgts): 50 at 10…

  • Direct Reading Titrator, Syringe Type For use in LaMotte field titration kits as well as in standard laboratory procedures such as dilutions and solution dispensing Plunger and barrel of propionate plastic; barrel has Luer slip tip Capacity 1 mL   All-purpose test…

  • …for the determination of the titratable total acidity in the process of wine making. This minititrator gives you direct readings in g/L of tartaric acid, with a range of 0.0 to 25.0 g/L. The instrument comes with a pre-programmed analysis method for the titratable total acidity measurements on…

  • LaMotte

    Direct Reading Titrator For determining levels of sodium in natural and treated waters Range 0 to 500 ppm sodium in 10 ppm increments Test requires three titrations: one to determine bicarbonate and carbonate ions; one to determine sulfate and chloride ions; and one to determine calcium and…

  • LaMotte

    …plastic, w/cap (1)                    Direct Reading Titrator, 0 - 10 Range (1)                    Spoon,…

  • Milwaukee Instruments

    …mini-titrator for the determination of free and total sulphur dioxide in the process of wine making. This mini-titrator will give you direct readings with a range of 0 to 400 ppm. The instrument comes with a pre-programmed analysis method for free and total sulphur dioxide measurements…

  • Thermo Scientific Orion

    …eliminating additional equipment set-up, titrations and calculations. The Thermo Scientific™ Orion™ Total Alkalinity Test Kit provides two-step direct measurement of total alkalinity and pH using a pH electrode. Direct reading of total alkalinity from 0 to 200ppm as…

  • … Don't miss a reading – AUTO-READ* locks in the stable reading on your screen, ready indicator alerts when readings are stable and timed reading gathers data in specific time intervals Calibrate using water-saturated air, air-saturated water, a Winkler titration or zero point calibration…

  • … Don't miss a reading – AUTO-READ* locks in the stable reading on your screen, ready indicator alerts when readings are stable and timed reading gathers data in specific time intervals Calibrate using water-saturated air, air-saturated water, a Winkler titration or zero point…

  • Micro Essential

    …at 0-5-10-20 grains per gallon. A reading of 5 grains per gallon indicates moderately hard water. The second roll of test paper has color chart matches at 10-20-30-50 grains per gallon and is used for testing known hard water sources. Product Directions The Hydrion Water Hardness Test…

  • … English, Spanish, French, Italian, German and Chinese Don't miss a reading – AUTO-READ* locks in the stable reading on your screen, ready indicator alerts when readings are stable and timed reading gathers data in specific time intervals Up to five point pH calibration…

  • …calibrations for user-specific applications. The large easy-to-read display eliminates meniscus reading errors while showing volume range, as well as showing if the unit is set to fill or titrate. Reagent recirculation system eliminates reagent loss. All valves are interchangeable. Luer-Lock…

  • Micro Essential

    …Iodine Kit provides an easy way to estimate the amount of titratable iodine in sanitizing solutions made with commercial iodophors. The color chart is easy to read and has color matches at 0-12.5-25-50ppm(parts per million) of titratable iodine. Federal, State and Local health regulations…

Compare Tool

Select up to 3 products