Culture Tubes Autoclavable
-
Culture Tubes, KIM-KAP®, Polypropylene Closures, Autoclavable, Color Coded
DWK Life Sciences (Kimble)Color Coded - natural, red, green, yellow and blue
-
Culture Tubes, KIM-KAP®, Polypropylene Closures, Autoclavable, Color Coded
DWK Life Sciences (Kimble)Color Coded - natural, red, green, yellow and blue
-
Culture Tubes, KIM-KAP®, Polypropylene Closures, Autoclavable, Color Coded
DWK Life Sciences (Kimble)Color Coded - natural, red, green, yellow and blue
-
For 9195R10 series plant tissue culture tubes Autoclavable caps available in natural or orange color. Two positions: closed, for humidified environments; and open, for gas exchange. Drip ring minimizes contamination. Flexible interval ribs hold cap firmly in place.
-
…tubes are autoclavable to 122°C and freezable to -90°C. Polystyrene tubes are not autoclavable but have a nominal temperature range between 90°C and -40°C. Polyethylene caps are not autoclavable, but are available sterile with many of the tube packages. Polypropylene tubes can be…
-
1.1ml or 0.65ml capacity Polypropylene - autoclavable and freezable to -80°C Ideal for preps and dilutions that are ultimately carried out in 96 well plates. Also used for large volume screening, HIV testing, cell harvesting and storage. Compatible with multi-channel pipettes and…
-
1.1ml or 0.65ml capacity Polypropylene - autoclavable and freezable to -80°C Ideal for preps and dilutions that are ultimately carried out in 96 well plates. Also used for large volume screening, HIV testing, cell harvesting and storage. Compatible with multi-channel pipettes and…
-
…tubes are autoclavable to 122°C and freezable to -90°C. Polystyrene tubes are not autoclavable but have a nominal temperature range between 90°C and -40°C. Polyethylene caps are not autoclavable, but are available sterile with many of the tube packages. Polypropylene tubes can be…
-
…tubes are autoclavable to 122°C and freezable to -90°C. Polystyrene tubes are not autoclavable but have a nominal temperature range between 90°C and -40°C. Polyethylene caps are not autoclavable, but are available sterile with many of the tube packages. Polypropylene tubes can be…
-
1.1ml or 0.65ml capacity Polypropylene - autoclavable and freezable to -80°C Ideal for preps and dilutions that are ultimately carried out in 96 well plates. Also used for large volume screening, HIV testing, cell harvesting and storage. Compatible with multi-channel pipettes…
-
Borosilicate N-51a Glass Tissue Culture Tubes
DWK Life Sciences (Kimble)…250 tubes. 9215D65 Tube takes size 18-415 cap and is sold in cases containing 2 shelf packages of 250 tubes. 9215E18, E26 and E34 caps are of black phenolic plastic with cemented rubber liner and are autoclavable. 9215E52 caps are polypropylene, without liner and autoclavable. Listings indicate tube…
-
Disposable Culture Tubes
Simport…polypropylene, these tubes are ideal for use in bacteriology, RIA, coagulation and other routine laboratory procedures. No mold release agents are used that could cause errors and interferences in RIA tests. Precision molded with virgin thermoplastics ensures that the tubes are uniform in size and…
-
…tubes are autoclavable to 122°C and freezable to -90°C. Polystyrene tubes are not autoclavable but have a nominal temperature range between 90°C and -40°C. Polyethylene caps are not autoclavable, but are available sterile with many of the tube packages. Polypropylene tubes can be…
-
Culture Tubes with Screw Caps
DWK Life Sciences (Wheaton)…expansion borosilicate glass that conforms to ASTM Type I, Class B and USP Type I requirements. The tubes can be reused many times. The caps have a white 14B styrene-butadiene rubber liner or a PTFE faced 14B styrene-butadiene rubber liner. For use as slant or shake cultures Autoclavable
-
Round Bottom Culture Tubes with Caps
United Scientific SuppliesTubes with round bottoms are manufactured from ASTM E438 Type 1 Class A Borosilicate 3.3 glass. Includes polypropylene autoclavable screw cap with PTFE liner.
-
…tubes are autoclavable to 122°C and freezable to -90°C. Polystyrene tubes are not autoclavable but have a nominal temperature range between 90°C and -40°C. Polyethylene caps are not autoclavable, but are available sterile with many of the tube packages. Polypropylene tubes can be…
-
For 48 x 0.5ml or 1.5ml tubes Recyclable polypropylene / autoclavable These racks are designed for 0.5ml and 1.5ml tubes. They hold 48 tubes in 4 rows of 12. Holes are alpha-numerically indexed and on an incline for visibility of all four rows.
-
For 48 x 0.5ml or 1.5ml tubes Recyclable polypropylene / autoclavable These racks are designed for 0.5ml and 1.5ml tubes. They hold 48 tubes in 4 rows of 12. Holes are alpha-numerically indexed and on an incline for visibility of all four rows.
-
These PYREX® culture tubes are supplied with phenolic caps to facilitate handling and sealing after autoclaving. Caps are fabricated from a special formula resistant to the effects of temperature and steam in autoclaving and are provided with a glued-in, white rubber liner. The white enamel…
-
Morton® Culture Tube Closures
Bal SupplyThe stainless steel cylindrical closures are excellent for microbiology and related applications. Non-contaminating closures may be autoclaved repeatedly without loss of resilience. The indentations on the top surface permit adequate exchange of gasses under aerobic and anaerobic conditions, yet…
-
mini-BioProducer12 Steamer Autoclavable Hollow Fiber Cartridges, 1.0mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
mini-BioProducer41 Steamer Autoclavable Hollow Fiber Cartridges, 2.0mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
mini-BioProducer41 Steamer Autoclavable Hollow Fiber Cartridges, 0.5mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
mini-BioProducer12 Steamer Autoclavable Hollow Fiber Cartridges, 0.5mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
mini-BioProducer24 Steamer Autoclavable Hollow Fiber Cartridges, 1.0mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
… Completely autoclavable Precisely controlled grinding clearance Pestles and vessels interchangeable Precision-made for uniformity. Pestle shaft is 178 mm long with 4 mm diameter in sizes 0 and AA, 6mm diameter in larger sizes. Grinding vessel is a round bottom tube with 2 mm wall…
-
mini-BioProducer41 Steamer Autoclavable Hollow Fiber Cartridges, 1.0mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
mini-BioProducer24 Steamer Autoclavable Hollow Fiber Cartridges, 2.0mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
mini-BioProducer24 Steamer Autoclavable Hollow Fiber Cartridges, 0.5mm ID
WaterSep BioSeparations…pump operated perfusion systems. Bioreactor and steamer hollow fiber assembly can be autoclaved simultaneously. Aseptic/sterile applications, where autoclaving is required Clarification of cell culture and fermentation suspensions in primary recovery applications Cell harvest, excellent…
-
These PYREX® culture tubes are supplied with phenolic caps to facilitate handling and sealing after autoclaving. Caps are fabricated from a special formula resistant to the effects of temperature and steam in autoclaving and are provided with a Polytetrafluorethylene (PTFE) interface firmly…
-
Eppendorf 25mL Conical Tubes
Eppendorf…big Eppendorf Tube Family fills the gap between the volumes of traditional conical tubes of 15 mL and 50 mL. Optimized height, outstanding quality and specifications make these conical tubes ideally suited for cell biology e.g. for pooling media from T75 flasks, bacteria culture in midi prep size…
-
KIMAX Test Tubes With Marking Spot
DWK Life Sciences (Kimble)With marking spot and deep form, black phenolic plastic caps with cemented rubber liners Caps are autoclavable; see 9210R18 series for conditions (unattached) Listings indicate tube length x o.d. in mm
