Column Chromatography Glass

Compare Tool

Select up to 3 products

Column Chromatography Glass
1 - 32 of 167
Sort
View
Show

GFS

  • General purpose gravity eluted column having a PTFE stopcock and reinforced beaded top. Column is constructed using MEDIUM WALL TUBING. Glass wool (not supplied) is used to support column packing. Lower end of the column has a round bottom.

  • With 24/40 standard taper joint at top and a 2 mm bore stopcock at the bottom.

  • Flex-Column Economy Chromatography Columns

    DWK Life Sciences (Kimble)

    …available with inner diameters of 0.7, 1.0, 1.5 and 2.5 cm and lengths ranging from 4 to 170 cm. Short columns are most frequently used for ion exchange chromatography, sample desalting and semidisposable applications. Long columns are ideally suited for gel filtration and adsorption chromatography.

  • Large chromatography columns with o-ring grooved flat flanged tops and Ace-Thred bottoms. Column extenders and 5860 heads should be mated to columns with our 6517 series clamps. All columns and extenders are supplied with either a 7855-254 (4") or 7855-260 (6") silicone o-ring. For capfe o-rings,…

  • Rugged columns with internally threaded ends to which a wide choice of upper and lower end pieces can be fitted using 5837, 5838, 5841, 5842, and 5843 fittings. Available in a variety of lengths and diameters. Some sizes available with epoxy coating for added protection against scratches.

  • …purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Top Joint: ST 24/40 Note: since the chromatography column is…

  • Silica adsorbents for column chromatography Features Standard silica 60 , pore size ~ 60 Å Pore volume ~ 0.75 mL/g Highly porous, amorphous silicic acid in the form of hard, opalescent particles, prepared by precipitation of water glass with sulfuric acid For higher demands…

  • SYNTHWARE general purpose chromatography column with heavy wall design. With reinforced beaded top. Supplied with a PTFE stopcock. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with positive air…

  • …general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Top Joint: ST 24/40. Column packing is supported by glass wool (not supplied). Note: since the chromatography column is used with…

  • Internal threaded bottom drip adapter with or without flow regulator valve. 1/4"-28 or NPT internal threads. Supplied with packing support and o-ring. For use with all Ace-Thred chromatography columns.

  • Gravity Chromatography Columns

    DWK Life Sciences (Kimble)

    Gravity chromatography column manufactured from medium wall tubing with PTFE stopcock and in-line reservoir for containing liquid buffer Standard Taper joint size 24/40 These columns may be used alone or in combination with 420575-2440 flow control adapter A coarse porosity glass frit…

  • Disposable Chromatography Columns

    Evergreen Scientific

    …desalting. Chromatography columns are precision-molded in 5 ? and 7 ? sizes from premium-grade, chemically inert plastics. Polystyrene columns are glass-clear and appropriate for use with mild acidic (except oxidizing acids) and alkali solutions. Polypropylene columns are contact-transparent,…

  • …this inexpensive to setup and operate column. Column is constructed using MEDIUM WALL tubing. Glass wool (not supplied) is used to support column packing. Can be used with optional CG-1201 flow controller and CG-1200 reservoir. Connections between the column, reservoir and flow control adapter are…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top standard taper outer joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully minimized to…

  • For use as column end fitting that allows connection of appropriate size Ace-Thred to tubing connectors with NPT threads. Available in various Ace-Thred and NPT sizes. Most come complete with both a 100 micron and a 350 micron polyethylene filter.

  • …optional CG-1195 flow controller and CG-1194 reservoir. Column is constructed using MEDIUM WALL TUBING. Glass wool (not supplied) is used to support column packing. Lower end of the column has a round bottom. Connections between the column, reservoir and flow control adapter are made using…

  • …preparative chromatography system suitable for use to pressures of 50 psig, operation behind a shield is recommended. Resevoir is 2L or 3L capacity, epoxy coated and pressure tested. Complete item includes:Brass or glass manifold, pressure gauge, pressure relief valve, column, tubing, and…

  • …general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top spherical socket joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Joint: SJ 35/20 Note: since the chromatography column is used with positive…

  • Support stand assembly for bench scale size Chromatography columns. "H" shaped base stand and 122cm high stainless steel rod gives great stability for the larger bench scale columns. Stand comes complete with base, rod, support plate with hole, clamp holder, chain clamp and cork ring.

  • …four post support stand for large scale chromatography columns. Each stand is designed to fit either 24", 48" or 72" length glass columns. Each stand has a PTFE collar at the bottom and an adjustable stainless steel collar at the top to support the column. All stands have locking casters for…

  • Column Kit Complete Glass

    Agilent Technologies

  • Column Kit, Glass Empty

    Agilent Technologies

  • Ballotini main applications include: Chemical plants (where large inert surface areas are required) and for filters eg. fractionating columns Resin filler Shot blasting Burnishing (metal finishing) Gas chromatography.

  • General purpose column has a PTFE stopcock and a top outer joint. Glass wool (not supplied) is used to support column packing. Column is constructed using MEDIUM WALL TUBING. Can be used as a gravity eluted column or a flash column (as described by W.C. Still, M. Kahn and A. Mitra of Columbia…

  • Capto HiRes Ion Exchange Chromatography Columns

    Cytiva (formerly GE Healthcare Life Sciences)

    …IEX column format Capto HiRes Q and Capto HiRes S IEX resins are prepacked in high-performance Tricorn glass columns of two different sizes. The columns have fittings for simple connection to ÄKTA chromatography systems or equivalent high-performance systems. All column parts…

  • …remove polar interferences from the sample. Columns with Florisil® PR grade (magnesium silicate) sorbent have larger particle size than silica and NH2. Florisil has a pore diameter of 70Å. All columns are made of polypropylene (except 06476-29, made of glass) and feature Luer-slip outlet.

  • …purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top spherical socket joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Joint: SJ 35/20 Note: since the chromatography column is used…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a reinforced beaded top. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully minimized to prevent…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top spherical socket joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with a PTFE stopcock and a top spherical socket joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully minimized to prevent…

  • SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is…

  • Glass Column with Stopcock Plug

    DWK Life Sciences (Kimble)

    A general purpose column for analytical separations A plug of glass wool can be used to support the column packing PTFE stopcock plugs, 821001-0002 and 821001-0004, control the flow rate Manufactured from 33 expansion, low extractable borosilicate glass conforming to USP Type I…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.