  • Cold Trap Packing Tool

    PerkinElmer

    Cold Trap Packing Tool

  • Centrivap Cold Trap

    Labconco

    …15 minutes. Ultra-Low Cold Trap reaches -85°C in less than 30 minutes. Ready indicator illuminates when the collector coil reaches operating temperature of -40°C. Clear canister is attached to the left side of the cold trap and can hold various trap inserts. These trap inserts remove acids,…

  • CentriVap Cold Trap

    Labconco

    The CentriVap Cold Trap collects evaporated liquid from a CentriVap Concentrator, protecting an accessory vacuum pump from the corrosive effects of vapors and fumes emitted from samples. Exclusive features include: brushed, stainless steel and glacier white, epoxy-coated steel exterior with blue…

  • Cold Trap Packing Tool

    PerkinElmer

  • CA Series Cold Traps

    Yamato

    Efficiently traps water vapor and toxic substances discharged from vacuum oven and rotary evaporator to protect the vacuum pump Features Excellent choice to extract acid and organic solvents with the optional glass condenser Efficiently reduces vapor inhalation amount to the vacuum…

  • ATD Cold Trap Tube, Unpacked

    PerkinElmer

    Standard cold trap tube unpacked.

  • Cold Trap Nut for ATD

    PerkinElmer

    Two required per trap tube.

  • COLD TRAP -105, 230V CHINA,AUS

    Labconco

  • COLD TRAP -105, 230V SCHUKO

    Labconco

  • CENTRIVAP -105 COLD TRAP, 115V

    Labconco

  • Buchi Vacuum Pump V-700 & V-710 Accessories

    Buchi

    … solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also be installed. 1230D92 - Secondary Cold Trap, Glass, If dry ice is used instead of cooling water, a suitable cold trap can also be installed.

  • Buchi Vacuum Pump V-700/710 Secondary Condenser

    Buchi

    …residual solvent vapor after the pump. 1230D91 - Secondary Cold Trap, If dry ice is used instead of cooling water, a suitable cold trap can also be installed. 1230D92 - Secondary Cold Trap, Glass, If dry ice is used instead of cooling water, a suitable cold trap can also be installed.

  • COLD TRAP -105, 230V 60 HZ NA

    Labconco

  • COLD TRAP -105, 230V UK PLUG

    Labconco

  • Glass Trap for Ai -40°C Cold Traps (Second Generation)

    Across International

    …International 500mL glass trap for Ai 2nd Gen T40 -40°C UL/CSA certified cold traps. Upward hose barb ports give you safer and easier vacuum tubing connection and removal. Attention! This new glass trap ONLY fits our new 2nd Gen UL/CSA certified T40 -40°C cold traps (released 9/2018).

  • Cold Trap Tube, Low Flow, Unpacked for ATD 400

    PerkinElmer

    Cold trap with reduced bore at one end. Allows minimum gas flow during trap desorption.

  • Vacuum Pump V-100

    Buchi

    …vacuum tubing. All Models Capacity, Final Vacuum 1.5 m3/h, 10 mbar 1190U86 Condensation assembly: Secondary cold trap Vacuum Controller: I-100 (Manual, Timer) Woulff Bottle: With 1190U87 Condensation assembly: Secondary condenser with…

  • Rotavapor® R-100 Rotary Evaporator

    Buchi

    … Glass Assembly: C (Cold trap) for low boiling point solvents Protective Coating: Without Recirculating Chiller: Without Vacuum Controller: I-100, with Woulff bottle Vacuum Pump: V-100, 1.5 m3/h, 10 mbar 1190U73 Glass Assembly: C (Cold trap) for low boiling point…

  • Glass Vacuum Cold Trap for Safe Vacuum Operations

    Across International

    …a cold trap not to condense liquid oxygen (a light blue liquid) into the cold trap. Liquid oxygen is potentially explosive, and this is especially true if the trap has been used to trap solvent. Liquid oxygen can be condensed into a cold trap if a pump has sucked air through the trap when the trap

  • Glass Traps for Ai T Series Cold Traps (First Generation only)

    Across International

    …a cold trap not to condense liquid oxygen (a light blue liquid) into the cold trap. Liquid oxygen is potentially explosive, and this is especially true if the trap has been used to trap solvent. Liquid oxygen can be condensed into a cold trap if a pump has sucked air through the trap when the trap

  • Trap Packing Disk

    PerkinElmer

    Glass fiber disk tor separating sorbents when packing ATD cold trap with multiple sorbents. Recommended when using low flow trap.

  • High Vacuum System Trap

    Ace Glass

    Vacuum trap system protects gauge heads, like our 14034, and pumps from corrosive vapors and particle fouling. System consists of a Dewar flask, cold trap and inlet arm. High-vacuum stopcocks are used throughout. Gauge & inlet arm are Ace-Thred connections. Pump & manifold connections are o-ring…

  • Dry Ice Trap 1/2' Inlet / Outlet

    Welch

    …volatile solvents. 2.8 L center well that holds a dry-ice and alcohol slurry capable of producing temperatures as low as -79°C (-110°F). Sealed with durable rubber gasket, traps can maintain cold temperature for up to 12 hours. Clear top on center well allows view of trapping surface.

  • Liquid Trap for RapidVap Vacuum Evaporation System

    Labconco

    …hooks that allow the trap to hang on the side of the RapidVap Vacuum System. Alternatively, the bracket serves as a stand to stabilize the glass container resting on a flat work surface. This trap may also be used with pre-2005 CentriVap Cold Traps. Liquid Trap prevents liquid from entering…

  • Graphite Ferrule

    PerkinElmer

    Ferrule for cold trap. Recommended for all applications except those using Mass Spec or ECD (Use P/N L4275110 PTFE Ferrule).

  • Traps, C Set, Rotary Evaporator

    Ace Glass

    …model R220 rotary evaporators. Traps are both inner and outer cold traps available either safety coated or plain. This improved version utilizes flat ground flanges on the inner and outer trap that is sealed together with a Duran quick- release clamp. Outer traps are supplied with two CAPFE o-rings,…

  • CentriVap Acid-Resistant System

    Labconco

    The CentriVap Vacuum Concentration System includes the following components: Acid-Resistant Benchtop Vacuum Concentrator with Glass Lid 7810016; Cold Trap 7811020; Clear Canister 7460900; Acid Insert 7814800; 12-13 mm Acid-Resistant Rotor 7455101; Glass Trap 7397605; and Vacuum Tubing and 6 Clamps.

  • Replacement Parts for Condenser, "C" Assembly

    Chemglass

    Two piece cold trap style condenser for use with rotary evaporators. Condenser has a 50mm flange on the side, a 35/20 lower ball joint, a 19/38 stopcock plug and removable hose connections using GL-14 threads.

  • Replacement Parts for Condenser, "C" Assembly, Constant Feed

    Chemglass

    Two piece cold trap style condenser for use with rotary evaporators. Condenser has an additional 19/38 outer joint sealed onto the condenser to allow continuous feed of volumes exceeding the capacity of the evaporating flask.

  • Buchi Evaporator Accessories

    Buchi

    A variety of accessories are available for use with Buchi evaporators

  • CentriVap Acid-Resistant System 115V/60Hz

    Labconco

    The CentriVap Vacuum Concentration System includes the following components: Acid-Resistant Benchtop Vacuum Concentrator with Glass Lid, Cold Trap, Clear Canister, Acid Insert, 12-13 mm Acid-Resistant Rotor, Glass Trap, and Vacuum Tubing and 6 Clamps.

  • Centrivap Concentrator Systems

    Labconco

    …of the components necessary to begin operation except for the vacuum pump, which is sold separately. Each system includes a benchtop concentrator, cold trap, clear canister, 12-13 mm rotor, vacuum tubing, 6 clamps and the appropriate trap insert. (See Thomas Numbers 4366R20 - R25 for vacuum pumps.)

Compare Tool