Coated Coverslips

Compare Tool

Select up to 3 products

Coated Coverslips
1 - 22 of 22
Sort
View
Show
  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PLL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PDL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PDL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …40mm Coverslips – 1178J99, 1178K00 & 1178K01 The disposable coverslip where you culture your cells to insert into the FCS2 or FCS3 chamber. Coverslips made from German Desag 263 low alkaline glass, they are #1.5 coverglass thick ~170 microns, and are 40mm in diameter. These coverslips

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PDL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …1.5 thickness, German, Desag 263 glass coverslip bonded to the bottom of the dish for high N.A. applications and are also available with 0.5mm thick glass for low N.A. applications. They have an electrically conductive, optically transparent, ITO coating on the bottom surface of the dish that when…

  • Cellulose tri-acetate film coated with a xylene-activated resin on the lower surface. The flexible film, with optical clarity compatible to glass, is automatically applied to the slide, eliminating the use of sticky mounting media and extended expose to xylene. Selectable mounted film length and…

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PDL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …that is adjustable in the Z-axis by rotation of a metal outer ring that rests on the top of the dish. Coverslip Weight – 1178J74 , Coverslip Spacer – 1178J75 , Coverslips #1.5 – 1178J73 The Coverslip weight is an accessory for Delta T Dishes that enables live cells gr

  • FCS2® System

    Bioptechs

    …temperature controller is used to pass a regulated current flow through the ITO Coating. This causes the surface of the slide to heat. The heat is transferred through the perfusable media to the cell surface on the coverslip thereby providing first surface thermal control. The self-locking base of…

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PDL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PDL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …microscope. It uses number 1.5 thickness cover glass bottomed dishes that have an electrically conductive, optically transparent coating of ITO on the underside. The coating is electrically powered to directly warm the contents of the dish. This is an exclusive technology to Bioptechs and provides…

  • …Fibronectin from bovine plasma is used for the following applications:. Used for coating the glass coverslips for the culture of decidual stromal cells (DEC). Cell movement assays (culture plates were coated with fibronectin). Cell spreading and immunofluorescence . Protein…

  • FD NeuroSilver™ Kit II

    FD NeuroTechnologies

    …User Manual Materials required but not included: Double distilled water Tissue culture plates (6-well) Histological supplies and equipment, including gelatin-coated microscope slides, glass coverslips, hair brush, staining jars, xylene or xylene substitutes and a light microscope

  • …provides you with an interchangeable warmed slide surface perfect for yeast, or mammalian specimens under a coverslip. Cells are placed on a disposable, or re-useable, 25mm X 60mm ITO coated slide that is inserted into the Thermal Slide Adapter. Then the Thermal Slide Adapter is placed in the…

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PLL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • FCS3® System

    Bioptechs

    …busbars. A temperature controller is used to pass a regulated current through the ITO Coating. This causes the surface of the slide to heat. The heat is transferred through the media to the cell surface on the coverslip thereby providing direct thermal control. The self locking base of the chamber…

  • …treatment of the polystyrene. Over the years, many researchers have shown that serum-free or reduced serum cultures can be dramatically improved by coating the culture surface with positively charged polymers (i.e., PLL). Poly-Lysine surface treatment improves adhesive properties by altering the…

  • …digestion. They will investigate how the properties of different enteric coatings react in different sections of the digestive system. Next they will explore the purpose of an enteric coating and engineer a simulated “coating” most suitable for certain pharmaceutical needs. This lab was written by a…

  • …and Benefits: Contents Lyophilizate, cell culture grade, 3 vials of 10mg Application: Collagen has been used in the preparation of coverslip coating solution and collagen gel contraction assay. Biochem/physiol Actions: Collagen provides extracellular support for multicellular…

  • FD Rapid GolgiStain™ Kit

    FD NeuroTechnologies

    … Double distilled or deionized water Plastic or glass tubes or vials Histological supplies and equipment, including gelatin-coated microscope slides, coverslips, staining jars, ethanol, xylene or xylene substitutes, resinous mounting medium (e.g. Permount®), and a light microscope

Attention Thomas Scientific Customers

Due to the current pandemic, lead times for PPE items are longer than what is listed on our website. Please expect shipping delays of all PPE products during this time.

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.