Chromatography Column With Reservoir

Compare Tool

Select up to 3 products

Chromatography Column With Reservoir
1 - 32 of 35
Sort
View
Show

  • SYNTHWARE Chromatography Reservoirs

    Kemtech America

    SYNTHWARE chromatography reservoirs with standard taper 24/40 joints or spherical 35/20 joints. Designed for use with flash chromatography.

  • Disposable Extraction Columns

    Evergreen Scientific

    …sample preparation, general chromatography applications and other research procedures and may also be used “piggybacked.” Columns measure 3-3/8 ? long and include a medium polyethylene filter matrix support. Large reservoirs and cartridge portions with straight sidewalls accommodate…

  • Empty Disposable PD-10 Columns

    GE Healthcare

    Columns are economical, plastic columns for single-use applications using gravity flow. The columns hold up to approx. 13 ml of chromatography media. The frits can be used as an upper bed support that prevents the medium from running dry under gravity flow. Together with LabMate Buffer Reservoir,

  • Gravity Chromatography Columns

    DWK Life Sciences (Kimble)

    Gravity chromatography column manufactured from medium wall tubing with PTFE stopcock and in-line reservoir for containing liquid buffer Standard Taper joint size 24/40 These columns may be used alone or in combination with 420575-2440 flow control adapter A coarse porosity glass frit…

  • C Columns

    GE Healthcare

    … Packing reservoirs for each column diameter optimize packing conditions. C columns are delivered with polyethylene tubing (1.0-mm ID, 2 m in length), bed support screens, snap-on net rings, and instructions. Columns are available in three diameters and several lengths.Compatible with a variety…

  • SYNTHWARE Chromatography Columns with Reservoirs

    Kemtech America

    …purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Top Joint: ST 24/40 Note: since the chromatography column is…

  • XK Columns

    GE Healthcare

    …The columns are made of biocompatible materials that exhibit excellent chemical resistance. A broad range of column dimensions makes XK columns suitable for many different purification needs. Column packing can be performed using either a packing reservoir or an extra column tube attached with a…

  • Sephadex G-25 in PD-10 Desalting Columns

    GE Healthcare

    …for PD-10 Desalting Columns A LabMate buffer reservoir can be used for one-step application of the column wash and equilibration buffer using the gravity flow protocol. It is not included with this product but can be purchased separately. Other Sephadex G-25 columns from GE GE…

  • SYNTHWARE Chromatography Columns with Reservoirs & Fritted Disc

    Kemtech America

    SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top standard taper outer joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is…

  • SYNTHWARE Chromatography Reservoirs with Rodaviss Joints

    Kemtech America

    SYNTHWARE chromatography reservoir with standard taper 24/40 Rodaviss joints. Designed for use with flash chromatography. Supplied complete with open top cap, Viton o-ring and loosenig ring.

  • His GraviTrap TALON

    GE Healthcare

    … Convenient histidine-tagged purification with high purity (> 90%) and binding capacity of up to 15 mg/column. Ready-to-use gravity flow column prepacked with 1 ml TALON® Superflow™ cobalt-IMAC (immobilized metal affinity chromatography) medium offering a different selectivity compared…

  • His GraviTrap

    GE Healthcare

    …is a prepacked, single-use column for purification of histidine-tagged proteins by immobilized metal affinity chromatography (IMAC). Column gives fast and simple gravity-flow purifications without any need for a purification The ready to use column is prepacked with Ni Sepharose 6 Fast Flow, which…

  • Flex-Column Economy Chromatography Columns

    DWK Life Sciences (Kimble)

    …available with inner diameters of 0.7, 1.0, 1.5 and 2.5 cm and lengths ranging from 4 to 170 cm. Short columns are most frequently used for ion exchange chromatography, sample desalting and semidisposable applications. Long columns are ideally suited for gel filtration and adsorption chromatography.

  • PYREX® Chromatography Column with Reservoir and PTFE Product Standard Stopcock

    Corning

    These PYREX® chromatography columns have a reservoir at top and a Product Standard 2mm bore PTFE (Polytetrafluorethylene) plug stopcock at the bottom. The top opening will accept a #2 rubber stopper.

  • Column 11X300mm

    DWK Life Sciences (Kimble)

    …is easily removed, providing easy access to column packing Tip and stopcock assembly are available as replacement components Replacement stopcock for all sizes is 41006F-2 17810 series has a 250 mL reservoir at the top of the column Manufactured from 33 expansion, low extractable…

  • SYNTHWARE Chromatography Columns with Reservoirs & Spherical Joints

    Kemtech America

    chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top spherical socket joint. Designed for flash chromatography. Column packing is supported by glass wool (not supplied). Joint: SJ 35/20 Note: since the chromatography column is used with

  • Chromatographic Column, 1:5 PTFE Plug, #15 Ace-Thred

    Ace Glass

    column with integral reservoir and #15 Ace-Thred at top, and 2mm bore 1:5 taper PTFE plug at bottom. Column supplied with 7506-06 Nylon bushing and FETFE O-Ring. Complete item consists of column with bushing and O-Ring, and 5853-07 Tubing Connector for connecting 12.5 to 14mm O.D. tubing to column.

  • Capillary Column Rinsing Reservoir Kit

    Restek

    columns by dissolving and removing soluble, nonvolatile residue, using this reservoir kit. The 50 mL rinsing reservoir is equipped with 1/4-inch inlet and outlet connections and includes a built-in fritted disk to prevent particulate matter from contaminating the column. The kit includes reservoir,

  • Disposable Chromatography Columns

    Evergreen Scientific

    …for use with mild acidic (except oxidizing acids) and alkali solutions. Polypropylene columns are contact-transparent, more chemically-resistant and appropriate for use with organic solvents and stronger acids (except oxidizing acids) and alkalis. Chromatography columns include reservoir &…

  • Cadmium Reduction Column

    DWK Life Sciences (Kimble)

    This column features all borosilicate glass construction with an 85 mL reservoir The glass wool plug and PTFE tubing at the bottom of the column are held securely in place by a BEVEL-SEAL™ connection, facilitating easy cleaning and assembly PTFE BEVEL-SEAL™ stopcock connector is…

  • Flex-Column 1.5X100cm Pk3

    DWK Life Sciences (Kimble)

    …adsorption chromatography. Constructed of polypropylene reservoirs and column outlets permanently connected to a borosilicate glass barrel 20 μm porosity polyethylene bed supports are fixed in the column outlet Luer lock inlets and outlets on the columns, along with a wide variety…

  • SYNTHWARE Chromatography Columns with Reservoirs, Spherical Joints & Fritted…

    Kemtech America

    SYNTHWARE general purpose chromatography column with heavy wall design. Supplied with an integral reservoir, PTFE stopcock and a top spherical socket joint. With a coarse porosity fritted glass disc to support column packing. Designed for flash chromatography. The section below the disc is carefully…

  • Injection Reservoir Bulb

    Ace Glass

    Injection reservoir bulb with Ace-Thred ends. 250mL to 3000mL sizes.

  • 3mL Column

    bioWORLD

    … C994D20) These columns are for use in drug extractions, HPLC sample preparation, general chromatography applications and other procedures. Columns measure 3 3/8 inches long an include a medium polyethylene filter matrix support. Large reservoirs and cartridge portions with straight sidewalls…

  • Flash glass columns

    MACHEREY-NAGEL

    Glass columns and kits for low pressure flash chromatography Economic low-tech method for the synthesis laboratory Suited for the separation of compounds up to gram levels No expensive equipment required MN flash chromatography kits include a glass column, eluent reservoir, silica 60…

  • Polypropylene Carboys with 1.5" Sanitary Flanges

    Thermo Scientific Nalgene

    …Thermo Scientific™ Nalgene™ Autoclavable Polypropylene Carboys with 1.5" Sanitary Flanges as dispensing ports or with secure hookup for supply reservoirs to systems such as fermentors or chromatography columns. Features: Molded-in handles for ease in transporting…

  • Column, Flash Chromatography, Spherical Joint, Epoxy Coated

    Ace Glass

    …absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and…

  • Column, Flash Chromatography, Epoxy Coated, Modified

    Ace Glass

    …& Nylon bushing make a pressure-tight, O-Ring compression seal with glass stem on reservoir & flow adapter. Bushing replaces joint clamp. Column & reservoir, only, are Epoxy Coated. Column available with or without Por.B (70-100m) fritted disc sealed in. Order each item separately…

  • Column, Flash Chromatography, Standard Taper Joint, Epoxy Coated

    Ace Glass

    …absorption chromatography column for rapid preparative separations with moderate resolution. Allows separations of samples from 0.01 to 10.0g3 in 10-15 minutes. Column and reservoir, only, are Epoxy Coated. Reservoir connects between column and flow control adap-ter. Joints on column, reservoir and…

  • Chromatographic Column, 1:5 PTFE Plug

    Ace Glass

    Chromatographic column with integral reservoir at top, and 2 mm bore 1:5 taper PTFE stopcock plug at bottom. Opening at top is either 24/40 outer joint or opening for #3 stopper. Available with or without porosity B (70-100micron), fritted disc sealed in.

  • Chromatographic Column, 1:5 PTFE Plug, Flow Control Connection

    Ace Glass

    Chromatographic column with integral reservoir for connecting 5872 Flow Control Adapter. With 2mm bore, 1:5 taper solid PTFE stopcock plug at bottom. Available with or without porosity B (70 - 100 m) fritted disc sealed in. Order column, flow control adapter and clamp separately.

  • Ion-Exchange Assembly, Laboratory Size #25 Ace-Thred

    Ace Glass

    …as Amborane. Borosilicate glass column has #25 Ace-Thred at both ends. Polypropylene end fittings form a leak-tight seal with FETFE O-Rings. Fittings have 1/4" npt female thread for connecting 3/8" O.D. flexible vinyl tubing from pump and reservoir using a 1/4" to 3/8" tubing…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.