Chambered Cover Glass

Compare Tool

Select up to 3 products

Chambered Cover Glass
1 - 32 of 37
Sort
View
Show
  • Lab-Tek™ I Chambered Cover Glass

    Thermo Scientific Nunc

    …medical grade silicone sealant #1 Borosilicate Cover glass is configured for 1, 2, 4 and 8 well unit. Cover is constructed of clear polystyrene. Non-removable media chamber is made of proprietary cell culture grade polystyrene. Cover glass thickness is between 0.13 and 0.17 mm. Number of…

  • Lab-Tek II Chambered Cover Glass

    Thermo Scientific Nunc

    …manipulations Biocompatible acrylic adhesive #1.5 Borosilicate Coverglass is configured for 1, 2, 4 and 8 well unit. Non-removable media chamber is made of proprietary cell culture grade polystyrene. Coverglass thickness is between 0.16 and 0.19 mm. Number of wells and growth area per well…

  • Rectangular Cover Glass

    Hausser Scientific

    5972M10 cover glass is for use with double-ruled chambers. 5972M20 cover glass is for use with Speirs-Levy Eosinophil Chamber.

  • Hemacytometer Cover Glass

    Hausser Scientific

    Cover Glass. For use with Double Neubauer Counting Chamber Set and BRIGHT-LINE* Hemacytometer Set. Dimensions: 20mm x 26mm x 0.4mm

  • Mold Counting Chamber

    Hausser Scientific

    …mm depth when a cover glass is placed in position Two parallel lines 1.382 mm apart traverse one side of the raised section for adjustment of field to 1.5 mm 2 circle AOAC method approved Supplied with one Cover Glass, Thomas number 3298N20 and one 3298N30 Cover Glass; both are 28 x…

  • Packaging 1 counting chamber, complete with 2 haemacytometer cover glasses, in transparent plastic box. Legal Information BLAUBRAND is a registered trademark of BRAND GMBH + CO KG BRAND is a registered trademark of BRAND GMBH + CO KG

  • Similar to 5971C10 Chamber, but for platelet count using phase microscope Without concavity beneath the rulings. No. 1 1/2 cover glass, 22 x 30 mm, should be used. Cover glass not furnished, see Thomas number 1208Q35.

  • The Corning counting chamber is a reusable glass cell counting slide for the Corning cell counter. This gridless slide has a 0.1 mm depth same as a Neubauer Hemocytometer and comes standard with two high quality cover slips. These slides have a notch for easy loading of cell suspension.

  • Hemacytometer

    LW Scientific

    …illumination. Neubauer rulings are 0.1mm below cover glass. The H-shaped moat offers two counting areas. Fused rhodium on glass provides distinct lines. High light transmission Brightly illuminated line Two special counting chamber cover glasses Light transmission between 29% and…

  • …into 25 groups of 16 small squares, each group separated by triple lines, the middle one of which is the boundary. The ruled surface is 0.02 mm below the cover glass, so that the volume over a square millimeter is 0.02 cubic mm. Count all cells within this center square millimeter (1mm x 1mm area).

  • …Reach-In/Environmental Chamber Solid Stainless-steel Shelf (224139) Reach-In/Environmental Chamber Perforated Stainless-steel Shelf (224155) Reinforced Stainless-steel Shelf (224161) Fixed Reinforced Stainless-steel Shelf for two shakers (1900005) Stainless-steel Door Glass Cover,

  • …position inside a 750 mL or larger Fast-Freeze Flask or Lyph-Lock Flask. Tubes and glassware are not included. Glass Lids Replace the acrylic lid that covers the collector chamber on any FreeZone Freeze Dry System. Recommended for applications involving solvents that attach acrylic. Includes…

  • In pocket-size polyethylene case with snap cover Includes 5971R10 Counting Chamber with two improved Neubauer rulings, two 0.4 mm cover glasses in removable polyethylene container and two Thomas diluting pipets, one for red and one for white cells.

  • Hausser Hy-Lite Kit

    Hausser Scientific

    Includes Thomas number 5971C10 Counting Chamber with double improved Neubauer ruling, two 20 x 26 mm cover glasses and two Thomas diluting pipets, one for red and one for white cells

  • Hemacytometer Bright Line

    Hausser Scientific

    …mm. Contact of the flat, polished cover glass surfaces with cover glass supports produces an exact volume of fluid over the counting area. The difference in surface tension characteristics between the metallic surface on the chamber and the polished cover glass assures smooth capillarity for precise…

  • Counting Slide

    Thomas®

    …Cell is cut from plane glass plate and fused to a polished glass slide. 75 mm x 25 mm x 2 mm thick. Forms flat-bottom chamber of approximately 0.1 mL capacity. Furnished with two plane cover glasses, No. 1 1/2, thickness 0.16 to 0.19 mm, 22 mm square. For cover glasses, see 6661K52 eyepiece…

  • …mm. Contact of the flat, polished cover glass surfaces with cover glass supports produces an exact volume of fluid over the counting area. The difference in surface tension characteristics between the metallic surface on the chamber and the polished cover glass assures smooth capillarity for precise…

  • Flow Cell Assemblies

    IBI Scientific

    …tape. Individual convertible flow cells are also available. The 3-Channel Flow Cell offers a triple chamber with a #1 glass cover slip attached to the cell with acrylic adhesive. The cover slip can be scored and removed for access to biofilm. Each channel requires a single pump cassette from…

  • …to fused-on, semitransparent metal layer V-shaped slit on the loading side of each counting area facilitates charging and minimizes overflow Chamber has concavity on the bottom, directly beneath the ruling Cell depth 0.1 mm; with two cover glasses, size 26 x 20 x 0.4 mm thick.

  • Tissue Culture Slide Flask

    Thermo Scientific Nunc

    Chamber floor is 18 x 50 mm; working volume approx. 5 mL Slide is 1 mm thick with frosted end for marking Flask and slide are ultrasonically welded together and may be separated at any step in the slide preparation procedure Sterilized by gamma radiation. 9384Z90 Cover Glass is 18…

  • Sedgwick-Rafter Cell

    Hausser Scientific

    …Methods for the Examination of Water and Wastewater, 15th Ed. (1980) Method 1002F Cell, 50 mm x 20 mm x 1 mm deep, is formed by four matte-surfaced strips cemented to 76 x 34 mm slide Overall thickness 3.5 mm. With one cover glass, 60 mm x 25 mm x 0.6 mm thick, plain on both sides.

  • Lab-Tek™ I Chamberslide Tissue Culture Slides are Sterile, Disposable Glass Slides with Detachable Chambers Soda-lime glass and Permamox plastic slide For microscopy of in situ cell culture Individual chambers can be used for different cell stains, can be subjected to separate…

  • …cells counted (practical: 200-500 per 0.1 mm3) In a conventional glass hemocytometer, improper fitting of the chamber and coverslip changes the volume of the sample introduced into the chamber. C-Chip’s chamber with integrated coverslip solves the problem.  It is a good standard…

  • Hausser Hy-Lite Hemacytometers

    Hausser Scientific

    …surface of the counting areas Light transmission is controlled between 29 and 32% Cover glasses, which are supported by four small, matte surfaces opposite the rulings Slide, which is provided with chamber charging inclines and with polished concavity beneath the ruling Condenser and…

  • Micro Bead Sterilizers

    Benchmark Scientific

    …small research tools (forceps, scissors, etc.). When the chamber is filled with the included glass beads, high temperatures (up to 300°C) can be used to eliminate the presence of bacteria, spores and other microorganisms. Chamber temperature can be viewed on the large LED control panel and…

  • …the only culture dish that provides heat to the contents of the dish without heating the stage of the microscope. It uses number 1.5 thickness cover glass bottomed dishes that have an electrically conductive, optically transparent coating of ITO on the underside. The coating is electrically powered…

  • …the sample chamber volume. The sample compartment optimizes the alignment of the sample for maximum sensitivity in the spectrophotometer. The sample is inserted and retrieved with a pipet. The cells have two polished windows and are supplied with a tight-sealing polypropylene cap and a Teflon cover.

  • …and a pilot light Tubing connections 6.4mm (1/4”) on the cover and housing accept tubes for circulating water or slurry Cover, grinding assembly and milling blade head are removable for cleaning Stainless steel chamber is 54mm diam x 25mm deep (2-1/8 x 1”) inside an aluminum…

  • …circuit is a stainless steel-encased thermistor. A motor-driven stirrer ensures a uniform temperature throughout the bath. The bath chamber is a cylindrical clear glass vessel 300 mm in diameter x 300 mm high. A second thermistor in the bath senses any over-temperature fault condition and removes…

  • …to 99 minutes; continuous run- indefinite time; and timed run- up to 99 minutes. The oven chamber is made entirely of stainless steel. A glass fiber reinforced silicone plate serves as a floor and covers the built in rotator. The plate is highly chemical resistant. All controls can be set with…

  • …laminated safety glass viewing window with powder-coated steel frame and neoprene gasket; interior-mounted anti-static ionizer fan; balance vibration isolator consisting of a marble slab, isolator pads and stainless steel cover; space-saving inner and outer transfer chamber doors that pivot upward,…

  • …Note, there is a simple process of growing cells on the basal surface of the membrane so that the cells can be imaged directly through the cover glass bottomed dish. Brain Slice Adapter – 1178J63 The Bioptechs Brain Slice adapter is an accessory designed for the observation of…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.