Ceramic Beads Homogenizer

Compare Tool

Select up to 3 products

Ceramic Beads Homogenizer
1 - 24 of 24
Sort
View
Show

  • Bulk Beads and Prefilled Kits

    Benchmark

    Supplied in bulk or in 2.0mL tubes-prefilled with beads Compatible with all common bead homogenizers Available in glass, ceramic or stainless steel Unique Triple-Pure™ grade: Acid washed, heat treated and tested free of nuclease Bead beating is quickly becoming the preferred…

  • Bead Ruptor Pre-Filled Bead Tubes

    Omni

    Bead tubes are pre-filled with an optimized amount of lysing matrix. Bead Media: Glass, Metal, Ceramic Compatible with: Bead Ruptor 4, 12 and 24 Certification: RNase & DNase free Soft Tissue Homogenizing Mix Recommended for: soft tissues, brain, liver, kidney, spleen,…

  • Lysing Matrix A, 50mL Tubes

    MP Biomedicals

    …Block, Sharp angular grains, Sub-angular to sub-rounded Each impact-resistant 50 mL tube contains garnet matrix and 50 (fifty) 1/4 inch ceramic sphere. Lysing Matrix A is used for all sample types except soil for the subsequent isolation of genomic DNA. This grinding matrix is chemically…

  • Lysing Matrix I, 2mL Tubes

    MP Biomedicals

    …isolation of intact organelles, and super-molecular structures where lysis conditions necessitate high impaction but low shearing. The 4 mm ceramic sphere provides very high inertia for lysis by impaction of tough chitin/protein composites that comprise the exoskeleton of arthropods and crustaceans.…

  • Lysing Matrix A, 15mL Tubes

    MP Biomedicals

    …Flakes, Block, Sharp angular grains, Sub-angular to sub-rounded Each impact-resistant 15 mL tube contains garnet matrix and 10 (ten) 1/4 inch ceramic sphere. Lysing Matrix A is used for all sample types except soil for the subsequent isolation of genomic DNA. This grinding matrix is chemically…

  • 1/4" Ceramic Spheres

    MP Biomedicals

    1/4" (6.35 mm) diameter Zirconium Oxide coated ceramic grinding spheres. Used to break hard/brittle samples. RNA Extraction from difficult samples. Lysis by impaction with minimal amounts of mechanical shearing. Chemically inert and will not bind nucleic acids. Component of…

  • Lysing Matrix A, 2mL Tubes

    MP Biomedicals

    …inch ceramic sphere. Extra 1/4 inch ceramic spheres are packaged separately. Lysing Matrix A tubes have orange caps and are found in the FastDNA™ and FastDNA™ SPIN Kits. Product Description: Each impact-resistant 2 mL tube contains garnet matrix and one 1/4 inch ceramic sphere.…

  • Lysing Matrix A, Bulk

    MP Biomedicals

    Lysing Matrix A is used for all sample types except soil for the subsequent isolation of genomic DNA. Garnet matrix and 1/4-inch ceramic sphere Impact resistant tubes Use for all sample types except soil Isolate genomic DNA, RNA, functional proteins and other metabolites and small…

  • Lysing Matrix D, 15mL Tubes

    MP Biomedicals

    …materials. Lysing matrix D is a critical component of FastPrep® sample preparation system. Each impact-resistant 15 mL tube contains 1.4 mm ceramic spheres. Applications Lysing Matrix D is used primarily for lysis of softer tissues like brain, liver, kidney, lung, and spleen. Also…

  • Mini-Beadbeater-96

    Biospec

    …microplate partially filled with tiny ceramic or steel beads. Complete cell disruption is achieved in 2 to 3 minutes of beadbeating. A common application is nucleic acid extraction. Up to 400 mg of tissue is added to a vial containing glass or ceramic beads and a nucleic acid extraction…

  • Lysing Matrix E, 2mL Tubes

    MP Biomedicals

    …Contains 1.4 ceramic spheres, 0.1 mm silica spheres, and one 4 mm glass bead. Lysing Matrix E tubes have purple caps and found in the FastDNA™ SPIN Kit for Soil and the FastRNA™ Pro Soil Kits. Product Description: Each impact-resistant 2 mL tube contains 1.4 ceramic spheres, 0.1…

  • Lysing Matrix Z, Bulk

    MP Biomedicals

    Lysing Matrix Z contains 2.0 mm diameter Yttria-Stabilized Zirconium Oxide beads. These beads have high density and extremely high hardness making this matrix ideal for cracking of very tough cell walls, while its smooth surface minimizes shearing. Lysing Matrix Z is used primarily for lysis of…

  • Lysing Matrix D, 96-Well Rack

    MP Biomedicals

    Each 96 deep well rack comes with 1.2 mL cluster-strip tube and cap assemblies. Each tube is pre-filled with 1.4 mm ceramic spheres. Lysing Matrix D is used primarily for lysis of softer tissues like brain, liver, kidney, lung, and spleen. Also used to lyse plant tissue such a leaves, roots, and…

  • Lysing Matrix M, 50mL Tubes

    MP Biomedicals

    Lysing Matrix M is used to break hard/brittle samples. Impact-resistant tube RNA extraction from difficult samples Lysis by impaction with minimal amounts of mechanical shearing Chemically inert and will not bind nucleic acids Lysing Matrices are critical components of the…

  • Lysing Matrix E, 15mL Tubes

    MP Biomedicals

    Each impact-resistant 15 mL tube contains 1.4 ceramic spheres, 0.1 mm silica spheres, and 8 (eight) 4 mm glass beads. Lysing Matrix E is primarily used for environmental samples such as soil, sludge, wastwater and feces. Lysing Matrix E can also be effective in lysing mixed samples, such as microbe…

  • Mini-Beadbeater-24

    Biospec

    …agitating four to twenty-four 2 ml screw-cap microvials containing small glass, ceramic or steel beads and 0.1 to 1 ml disruption buffer. Even resistant samples like yeast, spores or fibrous tissue are completely homogenized in 1-3 minutes. The non-foaming, aerosol-free method preserves enzymes and…

  • Lysing Matrix D, 50mL Tubes

    MP Biomedicals

    …materials. Lysing matrix D is a critical component of FastPrep® sample preparation system. Each impact-resistant 50 mL tube contains 1.4 mm ceramic spheres. Applications Lysing Matrix D is used primarily for lysis of softer tissues like brain, liver, kidney, lung, and spleen. Also…

  • Lysing Matrix E, 4.5mL Tubes

    MP Biomedicals

    Each impact-resistant 4.5 mL tube contains 1.4 ceramic spheres, 0.1 mm silica spheres, and 2 (two) 4 mm glass beads. Lysing Matrix E is primarily used for environmental samples such as soil, sludge, wastwater and feces. Lysing Matrix E can also be effective in lysing mixed samples, such as microbe…

  • Lysing Matrix E, 50mL Tubes

    MP Biomedicals

    Each impact-resistant 50 mL tube contains 1.4 ceramic spheres, 0.1 mm silica spheres, and 25 (twenty-five) 4 mm glass beads. Lysing Matrix E is primarily used for environmental samples such as soil, sludge, wastwater and feces. Lysing Matrix E can also be effective in lysing mixed samples, such as…

  • Lysing Matrix E, 96-Well Rack

    MP Biomedicals

    Each 96 deep well rack comes with 1.2 mL cluster-strip tube and cap assemblies. Each tube is pre-filled with 1.4 ceramic spheres, 0.1 mm silica spheres, and 1 (one) 4 mm glass bead. Lysing Matrix E is primarily used for environmental samples such as soil, sludge, wastwater and feces. Lysing Matrix E…

  • FastDNA® SPIN Kit for Feces

    MP Biomedicals

    …are placed into 2.0 mL tubes containing Lysing Matrix E, a mixture of ceramic and silica particles designed to efficiently lyse all stool organisms. Stool samples are pre-treated by washing in a Pre-Lysis Buffer. Homogenization takes place in the presence of MT Buffer and Sodium Phosphate Buffer.…

  • Mini-Beadbeater-16

    Biospec

    …agitating four to sixteen 2 ml screw-cap microvials containing small glass, ceramic or steel beads and disruption buffer. Even resistant samples like yeast, spores or fibrous tissue are completely homogenized around 3 minutes in 0.1 to 1 ml of extraction medium. The non-foaming, aerosol-free…

  • FastDNA® Kit

    MP Biomedicals

    …using Lysing Matrix A (garnet and one 1/4 ich ceramic bead) for cell lysis and a silica-based method for the purification process. Product Overview: Lysing Matrix A and 3 different chaotropic buffers are provided for the homogenization of a wide variety of sample types (plant and animal…

  • Soil DNA Extraction Kits

    IBI Scientific

    …DNA from microorganisms such as bacteria, archaea, fungi, and algae in soil samples. The soil sample is homogenized and disrupted using SL1 (lysis) Buffer combined with ceramic beads. Insoluble particles, proteins and PCR inhibitors such as humic acid are then precipitated with a unique inhibitor…

Compare Tool

Select up to 3 products

Please Log In

Don't have an Account? Create one now.