Biological Indicator Incubator
-
BI-O.K.® Biological Indicator Incubator
Propper ManufacturingThe Propper BI-OK® Biological Indicator Incubator is a universal incubation device designed for both the Steam and the EO gas indicator vials with 13 cavities for for incubation and 1 vial crushing cavity. The incubation temperature can be selected by setting the toggle switch on the bottom of…
-
3M™ Attest™ Biological Indicator Incubators
3M Health CareAttest Incubators provide optimal conditions for accurate readout of Attest Biological Indicators. Convenient, 14- or 28-vial capacity. Dry-block design pre-set to proper incubation temperature.
-
B/T Sure™ Biological Indicators
Barnstead…two days Simple, three step process Run indicator through standard sterilization cycle; compress plastic vial to break glass ampule inside and then incubate for a minimum of 48 hours. When complete, read color indicator: purple means effective sterilization; yellow and cloudy means…
-
Sterikon Plus Biological Sterilization Indicator
MilliporeSigma…with growth Rapid results; read after 24 hours Sterikon ® Plus indicators contain nutrient broth, sugar, a pH indicator and spores of apathogenic bacillus stearothermophilus. Following sterilization, the ampules must be incubated at 60°C for 24 to 48 hours. If sterilization is effective, the…
-
Duo-Spore® Biological Indicator System
Propper Manufacturing…Instrumentation (AAMI) ST-79 recommendations and U.S. Pharmacopeia (USP) Guidelines. Duo-Spore® Biological Indicator Strips Duo-Spore® Biological Indicator Strips are prepared from suspensions of Geobacillus stearothermophilus and Bacillus atrophaeus and encased in a peel-open…
-
…hours of incubation. 1251D07 indicators are designed for monitoring ethylene oxide (EO) sterilization processes. Detection media will turn yellow in the event of a sterilization process failure. The final readout of a negative result (media remains green) is made after 48 hours of incubation.
-
BI-O.K.® Self-Contained Biological Indicators
Propper Manufacturing…activation of media by crushing the glass vial, indicators need to be incubated at 57°C for steam and 37°C for EO Gas indicators. A color change in the media will indicate spore growth and sterilization failure. The Steam BI-OK® indicator is suitable for use in a standard AAMI linen…
-
SporAmpule® Liquid Biological Indicators
Hardy Diagnostics…couldn’t be easier with the convenient SporAmpule. Easy to use! Process one or more SporAmpules, along with your normal load, then incubate at 55-60°C for 48 hours and observe for a color change. No activation, crushing, or additional culture media is required with this…
-
Self-Contained Biological Indicators
Crosstex…the potential for false positives associated with post-exposure transfer. Reduced incubation time of 24 hours Visually distinct results Chemical Indicator on label provides instant indication of exposure Saves time by eliminating aseptic culturing required with traditional spore…
-
Basic Incufridge Incubating Refrigerators
Revolutionary ScienceThe Incufridge is the ultimate in flexibility when refrigerating or incubating temperature sensitive material. Each model is equipped with a PID controller and digital display. Two year manufacturer warranty included. Area of Focus Microbiology Food/Beverage Bacteriology …
-
Series 180 Incubators
Quincy Lab…180 series incubators pick up where the 140 series leaves off as far as temperature range, increasing the upper limit to 200°F (93°C). This series of models were also developed for laboratories that need a dependable, compact incubator for cultures, test kits, eggs and biologicals. For lab…
-
…that exhibits 91% amino acid sequence identity with murine LIF(Takahama etal 1998).Analysis of the secondary structure of rat and murine LIF indicates a difference in the two dimensional structure of both proteins. Studies have shown that rtLIF is more effective in maintaining the undifferentiated…
-
Prepared Culture Media (GMBCP)
Crosstex…exclusively formulated Trypticase® Soy Broth (TSB) modified with pH indicator. A reduced incubation time of 24 hours for steam and hydrogen peroxide (VH2O2) sterilization has been validated when Crosstex Biological Indicator Spore Strips and Discs are used in conjunction with Crosstex’s…
-
…in acetone, blocked with PBS/5% goat serum/ 0.1% Tween and incubated with a FITC-conjugated primary antibody prior to the addition of the AP-conjugated anti-FITC antibody. Application: Antibodies to FITC serve as universal indicator reagents by bridging FITC with another immunohistochemical…
-
PHMT Series Thermoshaker For Microtubes and Microplates
Grant Instruments…rooms and incubators. It is effectively three instruments in one: a microtube and microplate thermoshaker a compact benchtop incubator without shaking a microtube shaker without temperature control Features By combining the mixing operation with the incubation phase,…
-
…are important biological cofactors for oxidoreductase enzymes that are fundamental for various biological processes, such as energy metabolism, mitochondrial function, oxidative stress, immunological functions and cell death. Hence the oxidoreductase enzymes are used as indicators of metabolic…
-
PSU-10i Orbital Shaking Platform
Grant Instruments…operating temperature range of 4 to 40ºC allows use in cold room or incubator Integral electronic timer with audible alarm and automatic switch-off - accurate repeatability of time sensitive incubations 2 year manufacturer warranty The four interchangeable accessory platforms…
-
Helix 150 Orbital Shakers
LabStrong…continuous mode Audible buzzer when timed mode reaches zero Slow ramping start-up feature reduces potential splashing Timer and speed indicated on discrete LED displays Rotary knobs for setting speed and time Low-profile rubber feet designed to minimize vibration and provide…
-
…are important biological cofactors for oxidoreductase enzymes that are fundamental for various biological processes, such as energy metabolism, mitochondrial function, oxidative stress, immunological functions and cell death. Hence the oxidoreductase enzymes are used as indicators of metabolic…
-
1a,1b-dihomo Prostaglandin E1
Cayman Chemical…for several indications including peripheral occlusive vascular disease, erectile dysfunction, and in neonatal cardiology. COX metabolism of the unusual fatty acid 10,13,16-docosatrienoic acid yields 1a,1b-dihomo PGE1. This rare metabolite has been recovered from incubations of whole sheep…
-
PMS-1000i Microplate Shaker
Grant Instruments…the surface area of each well Applications: Suitable for mixing, incubation and cultivation of biological and chemical components in many life science disciplines including microbiology, cell and molecular biology, immunology and biotechnology. Specific applications include: immunoassays,…
-
ROCHE Pefabloc® SC PLUS