Ammonia Distillation
-
… UDK 129 far exceeds expectations from an entry-level distillation unit: Automated Operation System runs after setting sodium hydroxide addition and distillation time High Tech No loss of nitrogen: distillate temperature stays below threshold Accurate dosing of…
-
MIDI-VAP 4000 Distillation Systems
DWK Life Sciences (Kimble)…bench space. MIDI-VAP 4000 Systems feature an exclusive Watlow SD Digital Controller: Pre-programmed heating cycles for dual temperature ranges (ammonia and phenols is 165°C; cyanide is 126°C) Easy three-step setup saves time Automatic shutoff at test completion Amber light indicates heating…
-
Fully Automatic Kjeldahl Digestion Units for nitrogen analysis and protein determination that incorporate the revolutionary TEMS™ technology for unprecedented Savings in terms of Time, Energy - as much as 35%, Money and Space. High Technology Microprocessor control of precise…
-
…distillation), nitric nitrogen (after reduction/Devarda), phenols, volatile acids, cyanides and alcohol content. UDK 149 offers an upgrade pathway to combine distillation and titration. Automated Operation Programmable boric acid, water, sodium hydroxide addition and distillation…
-
Distillation Apparatus, Ammonia
Ace GlassGenerally used for the determination of ammonia in water. Joints are standard taper 24/40.
-
Ammonia In Water Distilling Unit
Corning…of flask, connecting tube and condenser Inlet tube on connecting tube permits the introduction of the permanganate solution after distillation of free ammonia. 9849F20 flask has Standard Taper 29/42 mouth; capacity is 500 mL. Condenser is coiled-tube type, 200 mm jacket length, with Standard…
-
General Distillation Apparatus
DWK Life Sciences (Kimble)…bottom and a distillation head with a 19/38 joint Supplied with a Standard Taper stopper Condenser is Graham-style, having a 200 mm jacket with a 19/38 joint at the top only For method, reference APHA Examination of Water and Wastewater: Method 4500-NH3 nitrogen (ammonia) in purified…
-
Semi-automatic Kjeldahl distillation unit for your analyses concerning different applications such as determining ammoniacal nitrogen, protein determination, nitrogen content (Kjeldahl or direct alkaline distillation), nitric nitrogen (after reduction/Devarda), phenols, volatile acids, cyanides and…
-
Ammonia Nitrogen Apparatus
DWK Life Sciences (Kimble)Apparatus is for determining the proteinaceous nitrogen content in water. It is also useful for preparing small quantities of distilled water. Apparatus can be used for phenol, selenium and fluoride determinations. It has 24/40 Standard Taper joint and a #2 hose connection. Unit measures 595 mm H x…
-
Ammonia HBA Test Kit
CHEMetrics…tests (except distilled water): Refill, Comparator, Stabilizer Solution, Catalyzer Solution, Activator Solution, 25 mL sample cup, 3 mL syringe, dilutor snapper cup, sample cup top, micro test tube and instructions. Krom, Michael D. Spectrophotometric Determination of Ammonia: A Study of a…
-
Ammonia HBA Test Kit
CHEMetrics…tests (except distilled water): Refill, Comparator, Stabilizer Solution, Catalyzer Solution, Activator Solution, 25 mL sample, 3 mL syringe, dilutor snapper cup, sample cup top, micro test tube and instructions. Krom, Michael D. Spectrophotometric Determination of Ammonia: A Study of a Modified…
-
Ammonia HBA CHEMets® Test Kit
CHEMetrics…needed to perform 30 tests (except distilled water): Refill, Comparator, Stabilizer Solution, Catalyzer Solution, Activator Solution, 25 mL sample cup, 3 mL syringe, and instructions. Krom, Michael D. Spectrophotometric Determination of Ammonia: A Study of a Modified Berthelot Reduction…
-
…petroleum refineries), or fertilizer runoff. Excessive ammonia concentrations are toxic to aquatic life. The Hydroxybenzyl Alcohol (HBA) Method In the ammonia test method that employs the Hydroxybenzyl Alcohol chemistry, free ammonia reacts with hypochlorite to form monochloramine.…
-
…effluents (particularly from petroleum refineries), or fertilizer runoff. Excessive ammonia concentrations are toxic to aquatic life. The Direct Nesslerization Method Reference: ASTM D 1426-08, Ammonia Nitrogen in Water, Test Method A. APHA Standard Methods, 18th ed., Method 4500-NH3 C…
-
Ammonia Vacu-vials Kit, Range: 0-14.0 ppm
CHEMetrics…effluents (particularly from petroleum refineries), or fertilizer runoff. Excessive ammonia concentrations are toxic to aquatic life. The Direct Nesslerization Method References: ASTM D 1426-08, Ammonia Nitrogen in Water, Test Method A. APHA Standard Methods, 18th ed., Method 4500-NH3…
-
Ammonia Vacu-vials Kit, Range: 0-7.00 ppm
CHEMetrics…effluents (particularly from petroleum refineries), or fertilizer runoff. Excessive ammonia concentrations are toxic to aquatic life. The Direct Nesslerization Method References: ASTM D 1426-08, Ammonia Nitrogen in Water, Test Method A. APHA Standard Methods, 18th ed., Method 4500-NH3…
-
Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-1000 & 1000-10,000 ppm MDL: 100 ppm Method: Direct Nesslerization …
-
Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-30 & 30-300 ppm MDL: 5 ppm Method: Direct Nesslerization …
-
Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-60 & 60-600 ppm MDL: 10 ppm Method: Direct Nesslerization …
-
Kit comes in a plastic case and contains everything needed to perform 30 tests (except distilled water): Refill, Low and High Range Comparators, dilutor snapper cup, micro test tube, and instructions. Range: 0-120 & 120-1200 ppm MDL: 20 ppm Method: Direct Nesslerization …
-
-
…to all the difficult transfer operations of powders or syrupy samples into mineralization test tubes. During the Kjeldahl distillation process, the ammonia content is condensed and collected in a boric acid solution to avoid loss of gaseous NH3. VELP unique Vreceiver™ is a certified…
-
Ammonium hydroxide solution, 20-22% NH3, Environmental
BeanTown ChemicalCAS: 1336-21-6 EC No: 215-647-6 MDL No: MFCD00066650 UN No: UN2672; Haz Class: 8; Packing Group: III Liquid, double sub-boiling quartz distillation Linear Formula: NH4OH MW: 35.05 Density (g/mL): 0.9
-
Micro Digestion Rack
LabconcoProvides accurate results for Kjeldahl digestions using either 30 mL or 100 mL flasks Two rear brackets provide adjustable mounting for glass manifold Each flask station consists of tubular heater element and stainless steel cup 200 Watt heater assemblies are recessed into top…
-
Kit Acid Or Base
Innovating Science…Cross Cutting Concepts: Cause and Effect; Scale, Proportion and Quantity Kit Includes: 30mL 0.01M HCl 30mL 0.01M NaOH 30mL Distilled Water 30mL Vinegar 30mL Dilute Ammonia 30mL Liquid Soap 30mL Lemon Juice Neutral Litmus Paper Spot Plates Developed for grades 3 – 5 WARNING CHOKING HAZARD…
-
Recirculating Water Pump that ensures optimum aspiration depending on the digestion phases and the number of samples placed in the digester connected to the pump. Optimized Performance Aspiration matches digestion phases and sample number Eliminates the problem of unreliable water…
-
SMS Scrubber
VELPDesigned to neutralize corrosive and toxic fumes produced during oxidative mineralizations or similar processes. Complete System Condensation in a water trap Neutralization with acids or bases Optional absorption with activated carbon Ideal for high fume levels such as with…
-
NiGen 40-1 Nitrogen Generators
OrganomationThe NiGen 40-1 nitrogen generator is designed for use with both LCMS and sample preparation equipment. It is compatible with all Organomation nitrogen evaporators up to 100 sample positions, along with all LCMS analyzers on the market. The NiGen includes a built-in oil-free compressor, making it…
-
IWT Ionxchangers
Evoqua Water Technologies…resin by color change High capacity compared to many other disposables - up to 1800 grains High flow rates up to 7.2 GPH Single or triple distillation water quality Transparent cylinders allow for easy detection of exhausted resin by color change. No need for costly conductivity meters. These…
-
… Indicators are available for acid vapors (e.g. hydrochloric acid, nitric acid, acetic acid and sulfur dioxide), ammonia, ammonia & hydrogen sulfide, basic vapors (e.g. ammonia and aliphatic amines), Formaldehyde, hydrazine, hydrogen sulfide and mercury. The indicator is easily connected inline…
