Air Sampling

Compare Tool

Select up to 3 products

Air Sampling
1 - 32 of 578
Sort
View
Show
  • …for environmental air monitoring - including those set by: ISO 14698, EU GLP-GMP, EN45001, ACGIH, USP 1116, and USP 797 Fast sampling time - less than six minutes for SAS Super 180 high volume air sampler to sample 1,000 liters of air; ten minutes for SAS Super 100 SAS air sampler Low running…

  • Straight sampling manifold, available with one end threaded, the other end reduced for use with 7506 bushing, or both ends threaded for use with either 7506 bushing or 5841 coupling. Also available with adjustable depth, threaded sampling ports for use with up to 7mm O.D. tube. Code identifies I.D.…

  • Straight tube type air sampling cane with polyethylene hood and stainless steel brackets. Codes -35 & -37 feature a #7 Ace-Thred port for introducing calibration gases.

  • …split capacitor, steel housed blower used to pull air through our Air Sampling manifolds. Blower produces 50 cfm @ 0.0 meters of water static pressure which assures a minimum pressure drop across each port in the manifold train. Free air rpm is 3030. Available in both 115 & 230v models,…

  • These small canisters are designed for controlled sampling, such as personal air sampling, as an alternative to tube and pump samplers. The 1,000 cc canister is suitable for sampling volatile organic compounds in air according to methods TO-14A, TO-15, IP-1A, ASTM 5466, OSHA PV 2120, and NJ DEP Low…

  • Air sampling cane with funnel at one end to avoid water droplets from collecting at edge and being sucked into manifold train. Bulge above the funnel is for glass wool or similar material to allow for filtering of particulates. Codes -22 & -26 feature a #7 Ace-Thred port for introducing calibration…

  • Tee, Air Sampling

    Ace Glass

    Sampling tee with top threaded, side and bottom tubes reduced for use with 7506 bushing.

  • Collection bottle, usually connected to the bottom arm of the 7495 tee with reduced ends, to collect heavy particulates before they enter the manifold train.

  • The vertically mounted Carb Octopus air sampling manifold design features an inner tube which allows condensation to drip to the collection bottle and away from the #7 Ace-Thred instrument ports. Available in standard 4 or 8 port configurations.

  • …adapter used for reducing air flow in the Air Sampling Manifold to prevent a pressure drop across the sampling ports. Normally installed in front of the 7511 blower, in line with the manifold. Positioning of holes in threaded nylon plug controls the volume of air flow. Plug supplied with O-Ring.

  • Quickly identify samples using Thermo Scientific™ Nalgene™ PPCO Low-Profile Micro Packaging Vial Closures, offered in a variety of colors. Closures are molded of high-purity, low metal-content polypropylene copolymer resin—excellent for PCR reagents. Features: Vials…

  • Restek's passive air sampling kit incorporates all the hardware necessary to collect air samples and is easy to assemble for field sampling.* The improved filter design greatly reduces the number of potential leak sites. The passive air sampling kit is available in seven sampling flow ranges and…

  • air sampling canisters feature our unique Siltek treatment technology. Even highly active components, at low parts-per-billion concentrations, can be readily sampled and stored without loss. The RAVE valve is a high-quality, metal-to-metal seal, 2/3-turn valve with metal diaphragms to prevent sample

  • …for grab air sampling Variety of orifice sizes for fast sampling from 5 to 60 minutes Connect 1/4" compression fitting directly to canister valve inlet Replaceable frit protects orifice and valve from particulates Sample inlet design minimizes water entry into sampling train …

  • Accessories for MD8 air sampling devices

  • A high velocity impinger which passes 6L/min (corrected to engineering gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.035in capillary tip that is positioned 4mm above…

  • …fatigue-resistant Large sample port for flushing; three convenient eyelets These bags are fabricated from 2 mil thick PVF (Tedlar) film, a material that is inert to a wide range of chemicals. Tedlar is manufactured without plasticizers. Can be used for collecting air containing all…

  • Tedlar® T.O. Plus Air/Gas Sampling Bags

    Environmental Sampling Supply

    The ESS Air Sampling Bag incorporates a two opening system for sampling and extraction. The side port/stem (3/16" OD) allows filling with a pneumatic pump and tubing, and for rapid emptying of the bag. The top of the valve is

  • Air Cadet™ Vacuum Pump

    Thermo Scientific

    Handle tough vacuum/pressure applications with ease using Thermo Scientific Air Cadet Single-head Vacuum/Pressure Pumps. Ideal for filtration, evacuation, flue-gas sampling, and other gas or air handling applications Compact size for portability Economically priced and can handle many…

  • Whatman PM2.5 Air Monitoring Membrane Filters

    Cytiva (formerly GE Healthcare Life Sciences)

    …for PM 2.5 ambient air monitoring. These high-purity, thin filters are sequentially numbered and come with chemically resistant polypropylene support rings. Robotic air sampling filter for PM 2.5 air monitoring Ambient air monitoring requires a chemically resistant air sampling filter that can…

  • Stainless steel and glass sample tubes are available with a wide variety of packing materials from single to multi-bed. PerkinElmer Thermal Desorber tubes are printed with the packing material and an arrow, which points to the end of the tube where sample is drawn from, and also indicates the end…

  • Restek’s passive air sampling kit incorporates all the hardware necessary to collect air samples and is easy to assemble for field sampling.* Kit includes flow controller, critical orifice, 2 µm frit filter, vacuum gauge, and sample inlet. The gauge and sample inlet are downsized for use…

  • …to 500°C. These grades are recommended primarily used in environmental air monitoring applications. Grade GB100R filters have very low trace metal content of As, Pb, Cd. Used in high and low volume air samplers for aerosols and airborne dust and metal contaminants. Gas Collection…

  • …designed to simplify both automated and manual air sampling. The easy-to-use keypad and graphic display facilitate the programming of up to 12 timed events. They offer the convenience of remote start/stop sampling and permit intermittent sampling throughout a test period. The LCD remains in sleep…

  • A high velocity impinger (Ref. AGI-4) which passes 12.3 to 12.6L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Sweep elbow, available with one end threaded, the other end reduced for use with 7506 bushing or both ends threaded for use with either 7506 bushing or 5841 coupling.

  • A high velocity impinger (Ref. AGI-30) which passes 12.0 to 13.0L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • AIR SAMPLING PUMP 120 V

  • … Stainless steel tee with orifice Variety of orifice sizes for sampling from 4 minutes to 10 hours 1-1/2" vacuum gauge (–30" Hg to 0" Hg) 2 µm frit filter for insertion into 1/4" compression sample inlet Air sampling canisters sold separately.

  • …valve U.S. EPA Methods TO-14A and TO-15 regulate the collection, storage, and analysis of volatile organic compounds (VOCs) using treated air sampling canisters. Restek offers a complete line of TO-Can canisters (SUMMA can equivalent), electropolished using a proprietary process and extensively…

  • Whatman Grade EPM 2000 Air Sampling Filter

    Cytiva (formerly GE Healthcare Life Sciences)

    …GE Healthcare Life Sciences) Whatman EPM 2000 air filters are used in high-volume PM-10 sampling equipment. Manufactured from 100% pure borosilicate glass, they enable detailed chemical analysis of trace pollutants with minimal interference. Air retention efficiency of 99.95 percent of 0.3 µm…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.