Air Sampling

Compare Tool

Select up to 3 products

Air Sampling
1 - 32 of 625
Sort
View
Show
  • Accessories for MD8 air sampling devices

  • Straight tube type air sampling cane with polyethylene hood and stainless steel brackets. Codes -35 & -37 feature a #7 Ace-Thred port for introducing calibration gases.

  • Restek’s passive air sampling kit incorporates all the hardware necessary to collect air samples and is easy to assemble for field sampling.* Kit includes flow controller, critical orifice, 2 µm frit filter, vacuum gauge, and sample inlet. The gauge and sample inlet are downsized for use…

  • …adapter used for reducing air flow in the Air Sampling Manifold to prevent a pressure drop across the sampling ports. Normally installed in front of the 7511 blower, in line with the manifold. Positioning of holes in threaded nylon plug controls the volume of air flow. Plug supplied with O-Ring.

  • These small canisters are designed for controlled sampling, such as personal air sampling, as an alternative to tube and pump samplers. The 1,000 cc canister is suitable for sampling volatile organic compounds in air according to methods TO-14A, TO-15, IP-1A, ASTM 5466, OSHA PV 2120, and NJ DEP Low…

  • Tee, Air Sampling

    Ace Glass

    Sampling tee with top threaded, side and bottom tubes reduced for use with 7506 bushing.

  • …designed to simplify both automated and manual air sampling. The easy-to-use keypad and graphic display facilitate the programming of up to 12 timed events. They offer the convenience of remote start/stop sampling and permit intermittent sampling throughout a test period. The LCD remains in sleep…

  • A high velocity impinger which passes 6L/min (corrected to engineering gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.035in capillary tip that is positioned 4mm above…

  • A high velocity impinger (Ref. AGI-4) which passes 12.3 to 12.6L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Sweep elbow, available with one end threaded, the other end reduced for use with 7506 bushing or both ends threaded for use with either 7506 bushing or 5841 coupling.

  • A high velocity impinger (Ref. AGI-30) which passes 12.0 to 13.0L/min. (corrected to engineering standard gas conditions) when the pressure drop across the orifice is 41cm Hg or greater. Stopper fits 24/25 125ml bottle and features a 11mm OD center tube, 8mm OD side arm with bulge, 0.05in capillary…

  • Collection bottle, usually connected to the bottom arm of the 7495 tee with reduced ends, to collect heavy particulates before they enter the manifold train.

  • …fatigue-resistant Large sample port for flushing; three convenient eyelets These bags are fabricated from 2 mil thick PVF (Tedlar) film, a material that is inert to a wide range of chemicals. Tedlar is manufactured without plasticizers. Can be used for collecting air containing all…

  • Straight sampling manifold, available with one end threaded, the other end reduced for use with 7506 bushing, or both ends threaded for use with either 7506 bushing or 5841 coupling. Also available with adjustable depth, threaded sampling ports for use with up to 7mm O.D. tube. Code identifies I.D.…

  • AIR SAMPLING PUMP 120 V

  • Restek's passive air sampling kit incorporates all the hardware necessary to collect air samples and is easy to assemble for field sampling.* The improved filter design greatly reduces the number of potential leak sites. The passive air sampling kit is available in seven sampling flow ranges and…

  • The vertically mounted Carb Octopus air sampling manifold design features an inner tube which allows condensation to drip to the collection bottle and away from the #7 Ace-Thred instrument ports. Available in standard 4 or 8 port configurations.

  • Air sampling cane with funnel at one end to avoid water droplets from collecting at edge and being sucked into manifold train. Bulge above the funnel is for glass wool or similar material to allow for filtering of particulates. Codes -22 & -26 feature a #7 Ace-Thred port for introducing calibration…

  • …for grab air sampling Variety of orifice sizes for fast sampling from 5 to 60 minutes Connect 1/4" compression fitting directly to canister valve inlet Replaceable frit protects orifice and valve from particulates Sample inlet design minimizes water entry into sampling train …

  • High-purity Whatman QM-B quartz fiber filters from Cytiva's business are designed for use in specific air monitoring applications.

  • …split capacitor, steel housed blower used to pull air through our Air Sampling manifolds. Blower produces 50 cfm @ 0.0 meters of water static pressure which assures a minimum pressure drop across each port in the manifold train. Free air rpm is 3030. Available in both 115 & 230v models,…

  • … Stainless steel tee with orifice Variety of orifice sizes for sampling from 4 minutes to 10 hours 1-1/2" vacuum gauge (–30" Hg to 0" Hg) 2 µm frit filter for insertion into 1/4" compression sample inlet Air sampling canisters sold separately.

  • air sampling canisters feature our unique Siltek treatment technology. Even highly active components, at low parts-per-billion concentrations, can be readily sampled and stored without loss. The RAVE valve is a high-quality, metal-to-metal seal, 2/3-turn valve with metal diaphragms to prevent sample

  • … U.S. EPA Methods TO-14A and TO-15 regulate the collection, storage, and analysis of volatile organic compounds (VOCs) using treated air sampling canisters. Restek offers a complete line of TO-Can canisters (SUMMA can equivalent), electropolished using a proprietary process and extensively…

  • Cytiva Whatman EPM 2000 air filters are used in high-volume PM-10 sampling equipment. Manufactured from 100% pure borosilicate glass, they enable detailed chemical analysis of trace pollutants with minimal interference. Air retention efficiency of 99.95 percent of 0.3 µm size particulates …

  • …fitting to open canister. Attach quick-connect stem protector to stem fitting when not sampling to prevent canister from accidentally opening. Connection: 1/4" tube fitting. Note: Quick-connect body fitting (cat.# 24187) must be ordered separately to sample with quick-connect stem fitting.

  • … U.S. EPA Methods TO-14A and TO-15 regulate the collection, storage, and analysis of volatile organic compounds (VOCs) using treated air sampling canisters. Restek offers a complete line of TO-Can canisters (SUMMA can equivalent), electropolished using a proprietary process and extensively…

  • Composite filters ideal for sampling airborne particulates

  • Tedlar® T.O. Plus Air/Gas Sampling Bags

    Environmental Sampling Supply

    The ESS Air Sampling Bag incorporates a two opening system for sampling and extraction. The side port/stem (3/16" OD) allows filling with a pneumatic pump and tubing, and for rapid emptying of the bag. The top of the valve is

  • Stainless steel and glass sample tubes are available with a wide variety of packing materials from single to multi-bed. PerkinElmer Thermal Desorber tubes are printed with the packing material and an arrow, which points to the end of the tube where sample is drawn from, and also indicates the end…

  • Sorbent: Carboxen 1008

Compare Tool

Select up to 3 products

Please Log In