  • Capillary Column Nuts for Agilent 5890/6850/6890/7890 GCs

    Restek

    Available in brass or stainless steel.

  • Inlet Adaptor Kit for Dual Column Installation for Agilent Capillary Injectors …

    Restek

    …two-hole capillary ferrules. Easier to install capillary columns due to the nut protruding farther from the insulated injection port chamber. Same column insertion depth as the original manufacturer's equipment. Kit includes adaptor fitting, 1/16" capillary nut, gold-plated…

  • Extended Capillary Column Nuts for Agilent 5890/6850/6890/7890 GCs

    Restek

    Visible below inlet insulating cup for easy, breakage-free column installation without removing cup. Finger-tight design to allow wrench-free use. Available for standard (1/16") and compact (Agilent-style) ferrules. Made from high-quality stainless steel. Meets or exceeds original…

  • Capillary Column Nut (fits Agilent injectors and non-MS detectors), hexagonal…

    MilliporeSigma

    These stainless steel column nuts are replacements for damaged or misplaced original Agilent nuts. Use with short ferrules. Hexagonal shape allows tightening with a wrench to keep fingers from getting burned.

  • Select PAH Capillary Columns

    Agilent Technologies

    Agilent J&W Select PAH is the first capillary column that provides a single solution for PAH analysis by separating all the isomers, thereby avoiding false positives and inaccurate results. It provides easy, fast, and accurate quantification of PAHs in environmental and food samples by resolving…

  • VF-624ms Capillary Columns

    Agilent Technologies

    VF-624ms, along with the VF-1301ms, are the world's first ultra-low-bleed 6% cyanopropyl/phenyl, 94% PDMS GC columns and provide more accurate trace analysis.

  • High Efficiency Capillary Columns

    Agilent Technologies

    High Efficiency 0.15 and 0.18 mm id columns are a simple and cost effective way to increase sample throughput with existing GC or GC/MS instruments.

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • Capillary Installation Gauge for Agilent GCs

    Restek

    Seats graphite* ferrules onto column for consistent installations Prevents crushed column ends Made from high-quality stainless steel *For use with graphite ferrules only.

  • Capillary Installation Gauge for Agilent 5973/5975 MS

    Restek

    Seats ferrules onto column for consistent installations Made from high-quality stainless steel

  • CP-Sil 5 CB Capillary Columns

    Agilent Technologies

    …points, making this column suitable for a wide range of applications with a broad temperature range Supplied with an EZ-GRIP to simplify column installation, coupling and operation Available in Fused Silica or UltiMetal to maximize choice Agilent J&W GC columns are tested against…

  • ZORBAX Capillary and Nano Columns

    Agilent Technologies

    columns and low dispersion HPLC instruments. The fastest growing application for capillary and nano columns is 2-D LC/MS for complex proteomics samples. Agilent provides all the columns needed for the 2-D separation - the SCX columns for the first dimension, the reversed-phase trapping column, and…

  • Capillary Column Rinse Kit

    Agilent Technologies

    Solvent rinsing removes many contaminants that accumulate in columns. The contaminants are removed by passing solvents through the column. Only bonded and cross-linked phase columns should be rinsed, or permanent damage to the column will result. This product is only available to U.S. Domestic…

  • Capillary Adaptable FID Replacement Jet for Agilent 5890/6850/6890 GCs

    Restek

    Engineered with a fluted tip to guide the capillary column into the jet. Standard Version Threads specially coated for easy installation and removal Special processing ensures the highest degree of cleanliness Meets or exceeds original manufacturer's performance …

  • Capillary Column Ferrules

    Agilent Technologies

    Capillary ferrules are packaged in dial packs which deliver one ferrule at a time, keeping the others clean and ready for use. The dial packaging has been tested to ensure no out gassing of contaminants, including phthalates. *These ferrules are recommended for use with Agilent GC/MS…

  • Capillary Column Installation

    Agilent Technologies

  • Capillary Column Splitters

    Agilent Technologies

    Variable Outlet System includes metal body and 5 meter 0.22 mm ID transfer line with 0.4 mm 2-hole ferrule.

  • Press-Fit Capillary Column Connectors

    Agilent Technologies

    In the past it was necessary to use Press-fit connectors with specific dimensions to connect columns of those dimensions. Modern Press-fit connectors are “laser-milled” to provide highly reproducible taper angles throughout the length of the Press-fit insuring an excellent seal. Now the…

  • Finger-Tight Capillary Column Nuts

    Restek

    Allow wrench-free column installations Available for standard (1/16") and compact (Agilent-style) ferrules Made from high-quality stainless steel

  • Columns Capillary HP-88 100m, 0.25mm id, 0.2um

    Agilent Technologies

    (88%-cyanopropyl) aryl-polysiloxane 250/320°C upper temperature limits High Polarity Designed for separation of cis/trans fatty acid methyl esters Even better separation than DB-23 of cis-trans isomers Similar Phases: CP-Sil 88, SP-2560, SP-2340, SP-2330, BPX-70, BPX-90

  • CP-Wax 58 FFAP CB Capillary Columns

    Agilent Technologies

    …polarity bonded wax column for analyzing polar compounds Chemically-bonded Solvent rinsable High inertness provides excellent peak shape Supplied with an EZ-GRIP to simplify column installation, coupling and operation Each Agilent J&W GC column is tested with the tightest…

  • J&W DB-1ms Ultra Inert Capillary GC Columns

    Agilent Technologies

    …general-purpose GC column and ideal for GC/MS of active analytes commonly found in drug screening and environmental analyses. The Ultra Inert 1ms GC columns set the new industry standards for consistent column inertness and exceptionally low column bleed. These columns allow you to perform…

  • Fused Silica GC Capillary Column

    Agilent Technologies

  • Parts For Interfacing Capillary Columns To W-Series Valves

    Agilent Technologies

  • DI Liner Adaptor for Agilent 5890 Packed Column GC

    Restek

    Uses standard 1/16-inch capillary nut and ferrules Convenient wrench pad at base Includes 1/4-inch graphite ferrule and stainless steel nut Use with Agilent or Restek DI glass inserts or Restek DI Uniliner liners for an Agilent 5890 packed column GC

  • DI Uniliner Liners for Agilent 5890 Packed Column GC

    Restek

    Press-Tight taper forms dead volume free connection to column Minimizes solvent and peak tailing Use with 0.25, 0.32, and 0.53 mm ID capillary columns Can be removed from the septum nut weldment

  • Inlet Maintenance Kit for Agilent GCs

    Restek

    …0.4, 0.5, and 0.8 mm ID graphite ferrules Viton O-rings Capillary nuts Inlet seals Reducing nut Scoring wafer 11 mm Thermolite septa 4.0 mm single taper liner 4.0 mm split liner with wool Capillary column caps 1/4" x 5/16" wrench Septum puller …

  • FastPack Inlet Kits for Agilent GCs

    Restek

    …Inlet Kits What are the benefits of using a FastPack Inlet Kit? Injection port maintenance should be performed prior to installing any capillary column, and on a routine basis, based on the number of injections made and the cleanliness of the samples. Maintenance includes replacing the injection…

  • Capillary and Fittings Kits

    Agilent Technologies

    Agilent starter kits contain the most often used capillaries and fittings. We included our genuine flexible stainless steel capillaries to make the best connection in your LC system, no matter the brand. The kits are for use with 3-4 or 1-2 mm ID columns, as well as for Micro LC columns. The free…

  • Ferrules for Agilent 5890, 6890 and 6850 Instruments

    Thermo Scientific

    …and capillary column ID. The choice of material is dependent upon the use. 15% Graphite/85% Vespel Ferrules The mechanically robust 15% Graphite /85% Vespel ferrules have a long lifetime and are compatible with GC/ MS. These ferrules form a strong grip with the column and cannot…

  • UltiMetal Plus Flexible Metal Ferrules

    Agilent Technologies

    …all Agilent capillary columns, including UltiMetal columns, plus a no hole, or plug ferrule to address all application needs Compatible with all Capillary Flow Technology devices - recommended for CFT backflush, effluent splitting, retention gap connections, GC by GC, Dean switch, or LTM column