PYREX Micro Volumetric Flasks
Corning…stability of this small flask, a hexagonal base, similar to those on all cylinders, has been added. The graduation line is sharp and permanent and the white markings are easy to read. Flasks with capacities of 1, 2 and 5 mL come with a No. 8 PYREX stopper while 10 and 25 mL capacity versions…
-
Permanent graduation line Machine-blown bodies Heavy-beaded, heavy-tubing necks are tooled for polyethylene stopper Stopper is made with a closed bottom and is of linear, high-density polyethylene to conform to Standard Taper stopper dimensions
-
KIMAX Brand Class A Volumetric Flasks
DWK Life Sciences (Kimble)…(4997L15 to L65) Flasks have marking spots on all sizes 10 mL and larger. The 2 mL size is test tube shaped; all other sizes are conventional flask shape. The 5 mL and larger sizes are designed from requirements for Type 1, Class A “unserialized” flasks of Federal Specification…
-
Polymethylpentene (PMP) and Polypropylene (PP) volumetric flasks provide a break-resistant alternative to glass. Flasks meet Class B per DIN EN ISO 1042. Flasks are supplied with matching PP screw cap or stopper. The 10 mL size allows for accurate measurement of small volumes. Screw cap…
-
Micro Class A Volumetric Flasks
DWK Life Sciences (Kimble)…Made to the following tolerances: 1 mL: ±0.01 mL; 2 mL: ±0.015 mL; 5 and 10 mL: ±0.02 mL; 25 mL: ±0.03 mL 1, 2 and 5 mL flasks take Standard Taper 8 stopper; 10 and 25 mL flasks take Standard Taper 9 stopper For micro-chemical work, sizes 1 through 5 mL are designed in accordance with the…
-
With barrel-shaped Standard Taper glass stopper Calibrated to contain at 20°C
-
…with ASTM Standard E 237 Made to the following tolerances: 1 mL : ±0.01 mL ; 2 mL : ±0.015 mL ; 5 and 10 mL : ±0.02 mL ; 25 mL : ±0.03 mL 1, 2 and 5 mL flasks take Standard Taper 8 stopper; 10 and 25 mL flasks take Standard Taper 9 stopper Reference: ASTM E-237
-
Individually calibrated to deliver at 20C. Durable ring marks resilient wear. Certified Class B with individual ring marking per DIN 122664. Supplied with screw cap. Specifications: Volume: 250ml Accuracy +/- Ml: 0.24 Height: 235mm Thread: 25 Case Quantity: 5
-
Falcon® CELL CULTURE FLASKS
Corning…injection-molded flasks Volumetric graduation acuracy (±5% of volume) Canted or straight necks Plug-seal or vented cap styles Vacuum-gas plasma tissue-culture treated polystyrene for uniform surface chemistry, cell attachment, spreading and growth. Flasks are blow-molded for…
-
Disposable Polypropylene Weighing Funnels
TWD TradeWinds, Inc.…flat on a balance. Small size fits volumetric flask volumes (mL) of 5, 10, 15, and 20. Medium size fits volumetric flask volumes (mL) of 100, 200, 250. Large size fits volumetric flask volumes (mL) of 500, 1000. X-Large size fits volumetric flask volumes (mL) of 1000, 2000.
-
Snap Cap No. 5 Cs 6
DWK Life Sciences (Kimble)Replacement snap caps for Class A serialized and certified volumetric flasks. Yellow polyethylene construction Fits Kimble® series 28000, 28008, 28010, 28010K and 28015 Fits flask size 200, 250, 500 mL Case of 6
-
…takes 1/4″ vacuum tubing. PP collection vessel rack accommodates autosampler vials; small scintillation vials (22.75 mm O.D. recommended); 10 and 16 mm test tubes; and 1, 2, 5, and 10 mL volumetric flasks. An optional plate for 20 mL scintillation vials is available for 12-port models.
-
Visiprep™ SPE Vacuum Manifold, Standard, 24-Port Model
MilliporeSigma…takes 1/4″ vacuum tubing. PP collection vessel rack accommodates autosampler vials; small scintillation vials (22.75 mm O.D. recommended); 10 and 16 mm test tubes; and 1, 2, 5, and 10 mL volumetric flasks. An optional plate for 20 mL scintillation vials is available for 12-port models.
-
NPW - Settleable Solids, NELAC range 5.0-50 mL/L
NSI Lab SolutionsA natural solid for quantitative transfer to a 1 liter Class A volumetric flask with dilution to 1 liter in reagent water. Formulated in the NELAC range of 5.0 - 50 mL/L. Each vial produces 1 liter of sample. (Supplied in duplicate)
-
…lines Total capacity of 63 mL Extremely low leachable metal content; each shipment comes with a metals background report Fit leading brand graphite digestion block systems Can be used as a digestion vessel, graduated cylinder, volumetric flask, autosampler tube, or storage container…
-
Protease Inhibitor Cocktail Kit
MP Biomedicals…to isolate/maintain intact proteins without degradation. Place the contents of all four vials in one volumetric flask or other suitable container. Add water or buffer of choice to 100 mL. More concentrated solutions can be prepared as desired; however, leupeptin and pepstatin A will create more…
-
…Class A tolerance for all 5 mL graduations Extremely low leachable metal content - each shipment comes with a metals background report Fit leading brand graphite digestion block systems Can be used as a digestion vessel, graduated cylinder, volumetric flask, autosampler Vessel, or…
-
Extraction System
Avantor - J.T.Baker®The BAKER SPE-12G is compatible with a large variety of glassware, including standard test tubes, volumetric flasks and autosampler vials. Samples are aspirated through disposable, prepacked extraction columns which selectively remove compounds from solution. Extracted compounds are then eluted…
-