27 Gauge Needle
-
Needle, Clear, 27 gauge, 0.5"
Jensen GlobalClear Threaded Luer Lock Hub; 27 gauge 0.5 inch High Precision tip - id inch:0.008(0.20mm) od inch:0.016(0.410mm). Polypropylene plastic threaded hub with burr free passivated stainless steel canula, bonded with a UV cured adhesive.
-
Tan, PrecisionGlide Allergy Tray Attached Needle Without Safety 1mL Sterile 27…
McKesson Medical-Surgical -
-
The BD reusable needle is made from strong 27 gauge stainless steel for added durability and impact resistance. The thin wall design of the design ensures good penetration into the skin and minimizes inflammation after use.
-
… Needles are sealed individually; protective plastic sheath is not removed until actual use. Color-coded hub identifies gauge, as follows: 30 gauge needle is beige; 27 gauge, grey; 26 gauge, tan; 25 gauge, blue; 23 gauge, turquoise; 22 gauge, black; 21 gauge, green; 20 gauge, yellow; 18 gauge, pink;…
-
The BD insulin syringe comes with a permanently attached needle that offers good penetration on any surface. The 27 gauge construction provides good durability and the sterile nature ensures the safety of the user.
-
The BD insulin syringe comes with a permanently attached needle that provides good penetration on any surface. The 27 gauge construction provides good durability and the sterile nature ensures the safety of the user.
-
HSW Fine-Ject Hypodermic Needles
Air-Tite…disposable single use needles are of the highest quality yet economical. Made of surgical stainless steel with polypropylene hub they are available in a wide range of gauge and length combinations. 15 through 25 gauge are thin wall construction while 27 through 30 gauge are regular wall. FDA…
-
Luer Lock Needles
Hamilton…plated brass. Needles are available from 33 to 10 gauge. This hub makes the most rigid connection to the needle making it perfect for repetitive septum piercing. Metal hub needles are compatible with PTFE Luer Lock (TLL) syringes. All needles are sold in six-packs and the standard needles are 51 mm…
-
Luer Lock Needles
Hamilton…Needles are available from 31 to 10 gauge. This hub is recommended when connecting to a rigid male Luer like a Luer Tip (LT) syringe because the plastic is more pliable and creates the best seal. All needles are sold in six-packs and the standard needles are 51 mm long. For all custom needles, the…
-
Needle guide allows easy penetration and prevents septum coring Manual injection septum nut allows use of 26-gauge needles for on-column injections Made of high-quality stainless steel
-
Includes: Capillary installation gauge for Bruker/Varian GCs 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless steel jet reamers (0.25–0.65 mm OD) 1/4" x…
-
Includes: Capillary installation gauge for Agilent GCs Inlet wrench for Agilent GCs Septum nut removal tool 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless…
-
… The Microseal septum uses a 23-gauge (0.63 mm, 0.025") needle or probe with a blunt, truncated conical tip. Since the syringe plunger end details are determined by manual or autosampler compatibility, often a removable needle syringe is an effective way to match both of these requirements.…
-
…low needle insertion force. The Microseal septum incorporates two separate sealing mechanisms. These sliding seals eliminate septum coring and the resulting accumulation of septum crumbs in the injection port liner. The Microseal septum uses a 23-gauge (0.63 mm, 0.025") needle or probe…
-
…port liner. Installation is simple, requiring no modification of the injection port. Compatible with Shimadzu models GC-2010 and GC-2025 only. 450°C maximum injection port temperature. For use with 23-gauge (0.63 mm, 0.025") needle or probe with blunt, truncated conical tip.
-
Includes: Capillary installation gauge for Thermo Scientific GCs Liner cap removing tool for Thermo Scientific GCs 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless…
-
Includes: Capillary installation gauge for Shimadzu GCs Inlet wrench for Shimadzu GCs 1/8", 3/16", and 1/4" nylon brushes 1/4", 3/8", and 3/16" stainless steel wire tube brushes Stainless steel surface brush 6 stainless steel jet reamers…
-
… The Microseal septum uses a 23-gauge (0.63 mm, 0.025") needle or probe with a blunt, truncated conical tip. Because the syringe plunger end details are determined by manual or autosampler compatibility, often a removable needle syringe is an effective way to match both of these requirements.…
-
… The Microseal septum uses a 23-gauge (0.63 mm, 0.025") needle or probe with a blunt, truncated conical tip. Since the syringe plunger end details are determined by manual or autosampler compatibility, often a removable needle syringe is an effective way to match both of these requirements.…
-
Merlin MicroShot Injector
Restek…standard autosampler syringe with less variation than when injecting by hand. The trigger mechanism provides rapid sample delivery, which reduces needle residence time in the injection port and minimizes potential sample discrimination. The Merlin MicroShot injector allows convenient sampling…
-
Reacti-Vap™ Evaporators
Thermo Scientific…or separate delivery of nonreactive pressurized gas to samples. Reacti-Vap PTFE-Coated Needles, made exclusively for use in Reacti-Vap Evaporators, are blunt-ended, 19-gauge, stainless steel needles that reduce cross-contamination and corrosion when evaporating solvents that contain strong…
-
On-column injections can be performed only with 0.53 mm ID columns because 26-gauge needles do not fit into the bore of 0.32 mm ID columns, or into the Unliner liner taper. Reduces solvent tailing Versatile—0.53 mm ID version can be used in the direct (DI) or on-column (OC) injection…
-
Protein-A Separopore® 4B
bioWORLD…cells, add the RIPA buffer to washed cell pellet in a 15 ml conical centrifuge tube. Disrupt cells by repeated aspiration through a 21 gauge needle and transfer to a 15 ml conical centrifuge tube. Wash cell culture plate with additional 1.0 ml ice cold RIPA buffer and combine with original…
