14 Ml Culture Tubes

Compare Tool

Select up to 3 products

14 Ml Culture Tubes
1 - 24 of 24
Sort
View
Show


  • …mm culture tubes For cell culture and general laboratory use With extra thick walls to prevent breakage ATP, RNase/DNase and Endotoxin Free (non-pyrogenic) Polystyrene USP Class VI resin Centrifuging to 1,500 x G Not Freezable to -80°C Not Autoclavable Capacity: 14 mL

  • Culture Tubes with Screw Caps

    DWK Life Sciences (Wheaton)

    These standard round-bottom culture tubes are manufactured from 51 expansion borosilicate glass that conforms to ASTM Type I, Class B and USP Type I requirements. The tubes can be reused many times. The caps have a white 14B styrene-butadiene rubber liner or a PTFE faced 14B styrene-butadiene rubber…

  • With lip Tubes 10 mm through 18 mm o.d. have marking spot. Listings indicate length x o.d. in mm.

  • Beaded rim These test tubes are well annealed, resistant to heat and chemically stable. Rims are fire-polished. The 25mm tube does not have a marking spot.

  • Polypropylene tubes have particularly good thermal, chemical and mechanical stability Material is ideally suited for the storage of chemical and biological samples Diameter: 17 mm; height: 100 mm Nominal volume: 14 ml Working volume: 12 ml

  • …easier 2.2 mL capacity Can be centrifuged Non-sterile Cube 2ube Tubes are uniquely designed to hold a larger capacity than a mini-tube, but less than a test tube. Tubes fit most automated liquid handling systems and can be centrifuged up to 14,000 rpm. Tubes can be frozen to…

  • Novarack Tube Storage Racks

    Diversified Biotech

    …to 46 tubes while using a single NovaRack at a fraction of the standard cost. Single-handedly, the NovaRack accommodates 24 microcentrifuge tubes (0.5-2 mL ), 14 tubes (12 x 75 mm culture tube, cryovial and a variety of blood collection tubes), 7 tubes (15 mL centrifuge tube) and one 50 mL tube.

  • …and controlled temperature models and a 3-liter capacity Skip steps in cell culturing Centrifuge cells directly in cell culture flasks Save time and labor Eliminate 15 mL or 50 mL conical tubes Reduce potential contamination steps Complete your run—even with…

  • Cell Factories

    Thermo Scientific Nunc

    …two chambers Total culture area 1,264 cm 2 Recommended minimum volume of medium 360 mL. Overall dimensions: 335 x 205 x 52 mm high; without bacterial air vent (see 4650C90) or tubing connectors (order 9383X16). 4-Chamber, Sterile (9383W82) Total culture area: 2528 cm 2 …

  • …urinalysis. Sterile pipettes are excellent for tissue culture application. Their low-affinity surface reduces sample, cell or protein loss. Whether you make your selection based on length, build draw, pipette capacity or number of drops per ml, one of these ten designs is likely to be suitable…

  • …Spin-X UF 6 concentrators are for samples up to 6 mL. Spin-X UF 20 concentrators can be used with either swinging bucket or fixed angle rotors; minimum rotor angle is 25º. Spin-X UF 20 concentrators are for samples up to 20 mL, 14 mL if using fixed angle rotors. Corning Spin-X UF Applications…

  • …Swing-bucket rotors and adapters accommodate tubes and bottles from 0.2 mL to 750 mL Plate rotors for centrifugation of all types of MTP, PCR, cell culture, or Deepwell Plates Fixed-angle rotors for high-speed applications in tubes from 0.2 mL to 85 mL High centrifugation speed of up to…

  • …Swing-bucket rotors and adapters accommodate tubes and bottles from 0.2 mL to 250 mL Plate rotor for centrifugation of all types of MTP, PCR, cell culture, or Deepwell Plates Fixed-angle rotors for high-speed applications in tubes from 0.2 mL to 85 mL High centrifugation speed of up to…

  • Large Shaking Incubator

    Techne (Cole-Parmer)

    … Angle adjustable accessory tube racks, with Magnetic coupling system available Communications enabled for external temperature measurement Combined shaker and incubator, ideal for scientists doing cell culturing procedures, especially suspension culture applications. The unit, whilst…

  • …2% solution of ferric chloride to 50 ml culture and 5 ml of 10% sodium hydroxide. Shake the tube to mix well. Stable copper color developing in a few minutes is positive reaction. OMeara Test (8): Add of 25 mg of solid creatine to 5ml culture and then add 5 ml concentrated (40%) sodium hydroxide.…

  • 14 grams in 1000 ml double distilled water. Heat to boiling to dissolve the medium completely. Dispense into tubes with screw caps to give a depth of approximately 7 cm. Sterilize by autoclaving at 15 lbs pressure (121°C) for 15 minutes and after sterilization, tighten the caps. Cool the tubes

  • …of 1 ml or less, use single strength medium. For inocula of 10 ml or more, double strength or proportionate medium should be prepared. After inoculation, incubate the tubes at 37°C for 24 to 48 hours. For every tube showing fermentation (primary fermentation), inoculate two tubes of Lauryl…

  • Pistol-shaped, with diaphragm-type pump, for filling and delivery from most pipets size 1 mL to 75 mL Silicone rubber nozzle socket takes pipets with 3 to 9.5 mm o.d. mouths Internal intake and discharge valves are operated by spring-loaded buttons on handle; finger pressure controls…

  • TOC Agar

    HiMedia

    …in tan to brown pigmentation. For the germ tube test, lightly touch a single colony from TOC Agar with a loop or Pasteur pipette; remove excess inoculum and then emulsify the yeast cells in 0.5 ml of horse or other serum in a small test tube with a loose cotton-wool plug. Failure to achieve…

  • …breakthrough functionality including: Increased Capacity and Processing Throughput Process up to 40 x 50 ml conical tubes (40% more) in a swinging bucket rotor, or up to 14 x 50 ml (100% more) in fixed angle configuration, for significantly increased capacity over competitive models in the…

  • …2% solution of ferric chloride to 50 ml culture and 5 ml of 10% sodium hydroxide. Shake the tube to mix well. Stable copper colour developing in a few minutes is positive reaction. OMeara Test (11): Add 25 mg of solid creatine to 5 ml culture and then add 5 ml concentrated (40%) sodium hydroxide.…

  • …dispersion of reducing substances and carbon dioxide formed in the environment (2). For blood culture work aseptically add 10 ml of sterile defibrinated blood to 150 ml of sterile medium in 300 ml Erlenmeyer flask. Incubate and subculture on other media. Storage and Shelf-life: Store…

  • …by a color change (red) in the medium after addition of sodium bicarbonate reagent. After incubation of 3-14 days, add 0.5 to 1.0 ml of 2N Na2CO3 to each tube and observe the color change within 30 minutes. Storage and Shelf-life: Store below 30°C in tightly closed container and…

Compare Tool

Select up to 3 products

Please Log In

Don't have a web profile? Create one now.