PerkinElmer Lab Supplies
-
Temperature range -60°C to 300/315°C.
-
This one-piece quartz torch, marked blue, with a PVDF o-ring free holder, has a 2.0 mm injector integrated directly into the torch. It's included in the Base Configuration's Sample Introduction Kit (N8150034).
-
Elite 624 capillary column 30m x 0.25mm, 1.40µm
PerkinElmerTemperature range -20°C to 240°C Equivalent to USP G43 phase
-
Universal Test Mix
PerkinElmerThe PerkinElmer 5 mL universal test mix has an alcohol fragrance and is used for the process of reverse phasing.
-
Elite-WAX capillary column 15m x 0.45mm, 0.42µm
PerkinElmerTemperature range 20oC to 250 oC, Equivalent to USP G14, G15, G16, G20, G39.
-
TheProgrammed Temperature Split/Splitless Injector Starter Kit includes the proper starter and/or replacement parts to keep your programmed temperature injector system operating at peak efficiency.
-
Secondary Standard Set Stray Light (UV Standard)
PerkinElmerThe cells are designed for usewith the standard 10 mm cuvette holders of most UV/Vis andUV/Vis/NIR Spectrometers. The test solutions comprising sodiumiodide, sodium nitrite, and potassium chloride, act as a cut-offfilter with a very precise wavelength. The set is provided in arobust aluminum…
-
PEEK Tubing, Outer Diameter: 1/16in, Inner Diameter: 0.007in, 5ft
-
-
-
Each PerkinElmer Cobalt (Co) Pure Grade Atomic Spectroscopy Calibration Standard is supplied with a comprehensive Certificate of Analysis that documents the quality and reliability. Concentration: 1,000 µg/mL Matrix: 2% HNO3 Volume: 125 mL
-
Zinc (Zn) Lumina Hollow Cathode Lamp
PerkinElmerSingle Element Lumina hollow cathode lamp (HCL) for the detection of elemental Zinc (Zn). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and…
-
Peristaltic pump tubing has a wall thickness of 0.84mm unless noted otherwise. Can be used with FIAS-200, AA, ICP-OES and ICP-MS.
-
Rheodyne™ Blunt Needle Syringe
PerkinElmerThe Rheodyne™ blunt needle syringe with luer hub is the best device to transfer fluids from vials and IV bags. The 22 gauge construction offers added strength and durability.
-
The sealed liquid cells have a corrosion-resistant construction making them ideal for highly volatile samples. The sealed liquid cells are ideal for quantitative analysis where you require an accurate reproducible cell thickness. These cells use a lead spacer which is amalgamated to the window…
-
The 32 cm PTFE drain line has a 1/4-28 spray chamber fitting. 160 cm of additional 0.8 mm I.D. drain line tubing is included.
-
Copper (Cu) Lumina Hollow Cathode Lamp
PerkinElmerSingle Element Lumina hollow cathode lamp (HCL) for the detection of elemental Copper (Cu). Every genuine PerkinElmer lamp is designed for use with and tested on PerkinElmer spectrometers to assure compatibility and the highest performance. PerkinElmer offers a wide range of single-element and…
-
Pd Matrix Modifier for AA THGA Graphite Furnaces
PerkinElmerWe offer standards speci cally for your Atomic Absorption (AA) instrument. From mixed standards to reagents, we have what you need for your AA analysis. The lead matrix modifier, with concentration 1% lead as nitrate, is used for atomic absorption THGA graphite furnaces.
-
The cell windows are fused to the bodies by a special process which avoids deformation of the windows. This assures that the full width of the cell is usable and the nished cell dimensions are maintained. Our cells are manufactured from various types of glass. We offer three basic materials:…
-
Maroon PVDF Syringe Filters, 0.45 µm, 17 mm
PerkinElmerOur superior premium 17 and 30 mm filters are suitable for coarse/crude samples or higher detection limit applications (such as food, beverage, or environmental analysis). These options provide improved filtration speeds and efficiencies due to an advanced pre-filter system and their larger…
-
These autosampler vials with fused inserts offers easy sampling for micro volumes.
-
The MicroMist micro-uptake glass concentric nebulizer offers high performance for limited sample volumes. MicroMists with sample uptakes 0.2 – 0.4 mL/min are fitted with a UniFit connector with 1.3 O.D. x 0.50 mm I.D. x 700 mm long sample tubing. MicroMists with sample uptakes 0.05 – 0.1 mL/min are…
-
Consumables for approximately 2500 digestions with High Pressure 100 mL (100 Bar) Digestion Vessels. Includes 10 Pressure Seals (N3133023), 7 Rupture Cap Discs (N3133022), 50 PEEK Ring Nuts (N3133011), and 5 Lip Seal Rings of the Gas Containment Manifold (N3134000).
-
Temperature range -20°C to 240/260°C.
-
Fruit & Vegetables EN 15662 Clean-up Kit, 15 mL
PerkinElmerQuEChERS kit with clean-up materials packed in ready-to-use tubes supporting EN 15662 methodology. Volume: 15 mL Quantity: 50 MgSO4 1 : 900 mg PSA 2 : 150 mg 1 MgSO4 removes excess water 2 PSA removes sugars, fatty acids, organic acids, and anthocyanine pigments
-
Splitter Split Liner with Wool 4mm
PerkinElmerSplitter Split Liner with Wool 4mm; 4mm I.D x 6.2mm O.D x 92.1mm length
-
The baffled cyclonic spray chamber, made of perfluoroalkoxy alkanes (PFA), is an all-purpose hydrofluoric acid-resistant spray chamber. It features o-ring-free connections to the nebulizer and torch injector, secure, leak-free threaded drain port, internal baffle, and threaded auxiliary port for…
-
-
Mixers T-Connector
PerkinElmerThe PerkinElmer mixers T-connector has a sturdy stainless steel construction for long-lasting durability and strength.
-
Solution-E6100DRC Setup/Stab/Masscal
PerkinElmerOur setup/stab/masscal solution is for use with the ELAN 6100 DRC for mass spectroscopy.
-
The PerkinElmer UHP-ZA zero air generators produce a continuous stream of organic impurity free air from an external dry compressed air source and offer superior limits of detection over and above other modes of supply. Flow rates range from 1 L/min to 30 L/min.