MilliporeSigma Chromatography Columns
-
SPB®-1 Capillary GC Column
MilliporeSigmaApplication This column is often used for traditional general purpose applications, where a non-polar column is required. Analytes will be separated primarily according to boiling point. USP Code: This column meets USP G1, G2, and G9 requirements. Phase: Bonded …
-
Kromasil® C18 HPLC Columns
MilliporeSigmaapplication(s) HPLC: suitable matrix active group C18 (octadecyl) phase suitability suitable for L1 per USP
-
Hibar® Pre-Column Holder
MilliporeSigmaThis precolumn holder is suitable for direct connection to Hibar® HPLC columns.
-
Discovery® DSC-18 SPE Tube
MilliporeSigmaRetention Mechanism: Reversed-phaseSample Matrix Compatibility: Aqueous solutions (biological fluids, water) •Polymerically bonded, octadecyl (18 %C), endcapped •Higher 18 %C loading for increased binding capacities and higher recoveries •The least selective phase: retains most organic analytes…
-
Discovery® C18 HPLC Column
MilliporeSigmaUse Discovery® C18 for any method that specifies a C18. The exceptional peak shape, reproducibility, and stability make it the column of choice for all C18 methods from demanding to routine. Legal Information: Discovery is a registered trademark of Sigma-Aldrich Co. LLC
-
Ascentis® Express C18, 2.7 mum HPLC Column
MilliporeSigmaAscentis Express HPLC columns, through the use of Fused-Core® particle technology, can provide you with both the high speed and high efficiencies of sub-2 mum particles while maintaining lower backpressures. The combination of high efficiency and low backpressure benefits UPLC® (or other ultra high…
-
Synonym: TSKgel® Size Exclusion (SW-Type) HPLC Column Physical form 20S isomer General description As the first generation of silica-based SEC columns, TSKgel G2000SW provides excellent separation of peptides and proteins with molecular weights up to 100,000 Da.TSKgel…
-
Ascentis® Express C18, 2.7 mum HPLC Column
MilliporeSigmaAscentis Express HPLC columns, through the use of Fused-Core® particle technology, can provide you with both the high speed and high efficiencies of sub-2 mum particles while maintaining lower backpressures. The combination of high efficiency and low backpressure benefits UPLC® (or other ultra high…
-
SPB®-35 Capillary GC Column
MilliporeSigmamaterial fused silica Quality Level 100 Agency meets requirements for USP G42 parameter 0-300 °C temperature (isothermal or programmed) Beta value 250 df 0.25 μm technique(s) gas chromatography…
-
Liquid chromatography columns Luer Lock
MilliporeSigmaAll of the columns listed below are constructed of borosilicate glass and are rated at a maximum pressure of 15psi (1 bar). Five configurations are available: A - Luer-Lock, Non Jacketed: Fixed polypropylene end caps, polyethylene bed supports, Luer-Lock inlet and outlet fittings.B - Luer-Lock,…
-
Supelclean(TM) LC-18 SPE Tube bed
MilliporeSigmaSupelclean(TM) LC-18 SPE tube is used in the extraction of nonpolar to moderately polar analytes from aqueous samples. Legal Information: Supelclean is a trademark of Sigma-Aldrich Co. LLC
-
Supel(TM) QuE Verde Tube
MilliporeSigmaDispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…
-
Empty SPE Tube (no frits)
MilliporeSigmaSolid phase extraction apparatus uses glass vials or tubes for sample collection and concentration. Some sorbents require large desorption volume than small SPE cartridges in such case SPE tubes were used. Synonyms: SPE Reservoir Application: Empty SPE Tube (no frits) was coupled with…
-
Purospher® STAR RP-18 Endcapped (5 µm) LiChroCART® 4-4
MilliporeSigmaPurospher® STAR RP-18 endcapped is the best choice for HPLC separation of basic, neutral, metal chelating samples or indeed any other format. Its outstanding performance and stability, allows a maximum flexibility in method development. Robust methods can be developed across the entire pH…
-
Synonyms: TSKgel® SWXL Columns Legal Information: TSKgel is a registered trademark of Tosoh Corporation
-
Ascentis® C18 Supelguard(TM) Guard Cartridge
MilliporeSigmaLegal Information: Supelguard is a trademark of Sigma-Aldrich Co. LLC
-
Discovery® BIO Wide Pore C5 HPLC Column
MilliporeSigmaeCl@ss 32110501 General Description Discovery BIO Wide Pore C5 was designed for the efficient and reliable separation of proteins and peptides, especially hydrophobic peptides, by RP- HPLC. Long-chain phases, like C8 or C18, are often too hydrophobic for proteins and can cause excessively…
-
Large Volume SPE Reservoir
MilliporeSigmaLarge volume SPE reservoirs are designed to increase the head space volume of standard polypropylene SPE tubes. Because these reservoirs are designed to connect directly to the mouth of the SPE tube, they are ideal for gravity applicatioins where increased headspace volume is required.
-
Purospher® STAR RP-18 Endcapped LiChroCART® HPLC Cartridges
MilliporeSigmaPurospher® STAR RP-18 endcapped is the best choice for HPLC separation of basic, neutral, metal chelating samples or indeed any other format. Its outstanding performance and stability, allows a maximum flexibility in method development. Robust methods can be developed across the entire pH…
-
Supel(TM) QuE Citrate Extraction Tube
MilliporeSigmaDispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…
-
LiChrospher® 100 RP-18 (5 µm) Hibar® RT 125-4
MilliporeSigmaLiChrospher® RP-18 is a reliable and versatile traditionally produced spherical silica gel carrier with C-18 reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds. This sorbent is packed into a Hibar® 125-4 HPLC column. For…
-
Ascentis® Express HILIC, 2.7 mum HPLC Column
MilliporeSigmaAscentis Express HPLC columns, through the use of Fused-Core® particle technology, can provide you with both the high speed and high efficiencies of sub-2 mum particles while maintaining lower backpressures. The combination of high efficiency and low backpressure benefits UPLC® (or other ultra high…
-
Ascentis® C18 Supelguard(TM) Guard Cartridge
MilliporeSigmaLegal Information: Supelguard is a trademark of Sigma-Aldrich Co. LLC
-
Discovery® DSC-Si SPE Tube
MilliporeSigmaRetention Mechanism: Normal phaseSample Matrix Compatibility: Organic solvents, oils, and lipids •Unbonded acid washed silica sorbent ideal for normal phase SPE and other modified flash techniques •Often used to separate or remove structurally similar molecules through successive elutions with…
-
Metal Packed GC Column (fits Agilent, Configuration "A")
MilliporeSigmaAn economical metal column should be used for less demanding applications where the inertness of glass is not required. This column fits Agilent 5880, 5890, 6890, 7820, and 7890 (configuration A, on-column injection, all detectors except TCD). In packed columns, the carrier gas percolates…
-
Supelclean(TM) ENVI-Carb(TM) SPE Tube
MilliporeSigmaGraphitized Non-Porous Carbon Retention Mechanism: Reversed-phase Sample Matrix Compatibility: Aqueous solutions (drinking, ground, waste water) •Surface area: 100m2/g; Particle Sz.:120/400 mesh •Extreme affinity for organic polar and non-polar compounds from both non-polar and polar matrices…
-
Supelclean(TM) LC-Si SPE Tube
MilliporeSigmaSupelclean(TM) LC-Si SPE Tube is used to adsorb moderately polar to polar compounds from nonaqueous samples. Legal Information: Supelclean is a trademark of Sigma-Aldrich Co. LLC
-
Female Luer Cap polypropylene
MilliporeSigmaUse to close Luer port. Polypropylene. Synonyms: Luer Plugs & Caps
-
SUPELCOSIL™ LC-18 HPLC Columns
MilliporeSigmaGeneral Description A general purpose hydrophobic alkyl phase that is very retentive and gives good peak shape for a wide variety of compounds.
-
Sequant® Zic®-Chilic (3mm,100 Angstrom ) HPLC Columns
MilliporeSigmaParticle Size: 3 µm Pore Size: 100 Angstrom
-
Supel(TM) QuE Acetate Tube, AOAC® 2007.01
MilliporeSigmaDispersive SPE (dSPE), often referred to as the "QuEChERS" method (Quick, Easy, Cheap, Effective, Rugged, and Safe), is modern sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. Using the QuEChERS method,…