Restek, Gas Chromatography
-
54-Piece Tool Kit
RestekSet comes with screwdrivers, pliers, wrenches, sockets, scissors, clamps, and more. Durable, zippered, notebook-style carrying case for easy transport.
-
Click-On Traps measure: 8 1/2" x 1 1/4" (21.6 x 3.2cm) Note: Replacement trap only—fittings sold separately.
-
UHP stainless steel regulators are the standard for ultra-high-purity and corrosion-resistant pressure regulation. They are more easily purged of atmospheric components compared to brass gas regulators, making them ideal for the most demanding applications. Stainless steel is especially useful in…
-
-
Fused silica adaptor ferrules are made from Valcon polyimide, a unique, graphite-reinforced composite specially prepared to maximize mechanical stability at temperatures up to 350°C. The determining factor for selecting adaptor ferrule size is the fused silica tubing OD.
-
-
PTFE Ferrules
RestekUpper temperature limit 250°C 100% PTFE; completely inert One-piece design requires no back ferrule
-
-
Reduces the release of hazardous materials from the capillary split vent into the lab Includes connecting lines and mounting kit
-
Flowmeters that can measure flammable gases are becoming mandatory due to the increased use of hydrogen in chromatography. With its Ex rating, the Restek ProFLOW 6000 meter is designed specifically with explosive and flammable gases in mind. The Restek ProFLOW 6000 is the only flowmeter you…
-
Rethreading Tool
RestekRepeated installation, removal, and temperature changes cause wear and damage to threads on GC parts. This can cause a poor seal, and oxygen can enter the system, compromising analytical results and possibly destroying expensive analytical columns. Repair worn or damaged threads Multiple…
-
Ideal for dirty samples. Spiral bore prevents nonvolatile residue from contaminating the column. Visually observe the Press-Tight connection between the column end and liner Fit 0.32 and 0.53 mm ID capillary columns (column ODs from 0.5 mm to 0.8 mm) Slotted top prevents obstruction of…
-
1/4 x 5/16in & 10mm x 11mm Open-End Set
-
Protocol Station
RestekThe protocol station is designed for convenient wall mounting of high-purity gas regulators. Wall mounting provides ease of use, prevents gas regulator damage, and improves safety. Either chrome-plated brass or 316 stainless steel option is complete with a 3-foot, flexible, all-stainless-steel…
-
Turn in-house compressed air into ultra-pure air (<0.1 ppm total hydrocarbons) Remove hydrocarbons to less than 0.1 ppm by catalytic oxidation Operate at 40–125 psi (276–862 kPa) Typical payback is less than one year, based on cylinder costs Install easily and take up…
-
Ensure even and consistent column heating when the insulation becomes damaged or worn Replacement Insulation Gasket and Hardware Kit includes the insulation gasket, 2 screws and 2 nuts Meets or exceeds original manufacturer's performance Insulation is replaceable, using Restek's…
-
Ceramic Scoring Wafer
RestekFour straight scoring edges for cutting fused silica tubing and four serrated edges for cutting MXT metal capillary columns.
-
Convert a capillary GC split/splitless inlet for use with 1/16" OD micropacked columns For use with Agilent 5890, 6890, and 7890 GCs Sample pathways deactivated for ultimate inertness
-
Allow wrench-free column installations Available for standard (1/16") and compact (Agilent-style) ferrules Made from high-quality stainless steel
-
Ion Source Cleaning Powder
RestekUse this aluminum oxide powder to clean surfaces that contact the sample or ion beam when you encounter poor sensitivity and inadequate abundances at high masses.
-
Restek has designed the EZ No-Vent GC column-mass spectrometer connector to be simple and easy to use. A critical orifice in the EZ No-Vent connector minimizes the amount of oxygen allowed into the MS source, eliminating the need for purge gas as is required for other manufacturer's vent…
-
Treated Seamless 316L Grade Stainless Steel Tubing High durability tubing. Recommended for: Inert applications High temperatures High pressures Corrosive environments Zero bleed
-
Photoionization (PID) Lamps
RestekModel 108-10.0/10.6 offers both 10.0 and 10.6 eV potential, has a 0.781" base diameter, and is used in Tracor, OI, and Baseline instruments. Model 103 has a 1.375" base and is used in HNU and SRI detectors. Model 108-BTEX lamp’s higher output makes it ideal for detection of BTEX compounds.
-
Certificates enclosed with each kit Vials of clear or amber borosilicate glass with ID marking spots Closures with pre-inserted septa Each kit sealed for integrity
-
Container, liner, and closure cleaned, assembled, and lot traceable Open-top caps PTFE faced 0.125" silicone septa Cleaned to U.S. EPA Protocol B specifications