Hamilton, Syringes
-
Syringe 725Npt5 250ul (22S/2"/5)
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. Stainless-steel plunger manufactured to fit the glass barrel with a tolerance smaller than 100 millionths of an inch, resulting in…
-
700 Series Microliter Syringes
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. The stainless steel plunger is manufactured to fit the glass barrel with a tolerance less than three thousandths of a millimeter, resulting in unsurpassed syringe life. This series of syringes is ideal for dispensing volumes from…
-
Cemented needles on 8928B58-64 Removable needles on 8928B67 Length: 2” Point style: 2 See 8928C40 for needle for 8928B67.
-
TLL Syringe
HamiltonThe Hamilton Super Syringe is a large volume Gastight syringe. These syringes are ideal for dispensing volumes from 50 mL up to 2 L. The Super Syringe is the only Hamilton syringe that is made with an acrylic barrel instead of a glass barrel.
-
Chromatography Syringes
Hamilton7000 Series Modified Microliter® Removable needles Replaceable barrels and parts No dead volume Positive displacement syringe for use with liquids. A tungsten plunger wire travels inside the needle, eliminating dead volume. Knurled hubs are used exclusively on the 7000…
-
The 1000 series syringe is a mid-volume Gastight syringe. Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined polymer plunger tip, often PTFE, which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe…
-
Point styles 2 and 3 Standard 2” length Needles seat precisely to the zero graduation mark of the syringe. They are autoclavablewhen disassembled. They allow the use of different specification needles with the same barrel. The small ‘s’ next to the gauge number indicates…
-
This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. The 1700 series syringes are the GASTIGHT version of the original 700 series syringes. A variety of different terminations and needle options are available in this series.
-
Teflon ® PTFE tipped plungers Replaceable barrels, plungers and tips Cemented or removable needles For use with liquids or gases. Features a precision-machined Teflon plunger tip which, when wetted, forms an interference fit with the inner diameter of the glass barrel to achieve the seal…
-
ThermoFinnigan AI-3000 & AS-3000
HamiltonSyringes for use with the Thermo Scientific 3000 Series II of liquid sampling systems for gas chromatography.
-
Digital Syringes
HamiltonThe most accurate manually operated syringes available Consistent plunger position LCD NIST Traceable Ergonomically designed syringes have a fine adjustment thumbwheel for easy volume control. Plunger drag adjustment optimizes the rate of plunger movement to the…
-
Plunger Guides
HamiltonPrevents plunger bending Adjustable stop prevents plunger damage Easily installed
-
Shimadzu SIL-6A Syringes
HamiltonThe most commonly used site for intramuscular injection is the thigh muscle. Quadriceps, rather than posterior thigh muscles, should be used for injection of irritating substances or larger volumes. [1] The products below are a selection of recommended small volume syringes and small gauge needles…
-
C-Line Syringes for CTC Autosamplers
HamiltonImprove operation and functionality Available for all GC and HPLC PAL Instruments Innovative cemented needle design making a more inert fluid path Inert plunger tip material that provides longer life and chemical resistance Ensure proper installation with color-coded needle gauge indicator and…
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Calibrated 7100 Series Syringes
HamiltonHamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. Calibrated precision syringes are available only at…
-
Calibrated 1700 Series Syringes
HamiltonHamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. Calibrated precision syringes are available only at…
-
Neuros™ Syringes
HamiltonHamilton Neuros™ syringe technology provides unprecedented functionality for controlled animal injections. An industry first, the Neuros™ accurately dispenses 50 nL to 100 μL of liquid through an ultrafine 30, 32, or 33 gauge needle protected by a custom-designed sleeve. Developed…
-
Needle Cleaning Kit
HamiltonA selection of various diameter tungsten wires for cleaning plugged needles and a biodegradable cleaning concentrate to help remove stubborn residues.
-
Shimadzu AOC-9 Syringes
HamiltonHamilton offers a wide variety of syringes specifically designed for Shimadzu autosamplers that require 43 mm needle lengths as well as standard 51 mm lengths.
-
Syringes & Accessories
HamiltonThe 7000 series syringes are considered modified Microliter syringes for their unique zero dead volume design. This syringe series is ideal for dispensing volumes from 0.05 µL up to 5 µL. The fine gauge plunger wire extends all the way to the tip of the needle ensuring that all solvent is expelled…
-
Bruker Varian 8100 and 8200 Syringes
HamiltonFor Varian 8034 Length: 2” Point style: 2 See 8928C40 for replacement needles. For Varian 8100/8200 Length: 1.99” Point style: 5 See 8928C47 for replacement needles.
-
Gastight syringes for injection of Gas and Liquid Samples. Removable Needle (RN), (point style 2) Autoclavable needles are 51 mm 22s gauge
-
Removable needles Length: 1.71” HP point style See 8928C19 series for replacement needle kits.
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1 μL up to 500 μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
1700 series syringes are the Gastight® version of the original Hamilton 700 series syringes. This series of syringes is ideal for dispensing volumes from 1μL up to 500μL. Gastight® syringes are ideal for dispensing both liquids and gases. They have a precision-machined PTFE plunger…
-
Microlab 500 Replacement Parts
HamiltonThe Hamilton 18 gauge dispense tubing with M6 fitting is 6 Feet long and is suitable for use with Microlab 500 diluter/dispenser system.
-
Calibrated 900 Series Syringes
HamiltonHamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. Calibrated precision syringes are available only at…
-
Syringes
HamiltonThe Hamilton gaslight syringe features ChemSeal (C, 1/4 Inch - 28) termination. This syringe model offers borosilicate glass, PTFE and PFA fluid path. It can be used at a temperature rating of up to 10 to 115 degree C.
-
1750 Hitachi Syringe
HamiltonThe LaChrom Elite Autosampler represents a new standard of performance in HPLC. Whether you need high sample capacity, extreme precision, ultra-low carry over, or rapid cycle times between injections, the LaChrom Elite models excel.
-
Multi-Channel Syringe Pipettes
HamiltonQuickly transfer 4, 6, 8 or 12 samples from microwell plates to sequencing gels, nylon membranes or another microwell plate Adjustable volume stops Minimize sample order error GASTIGHT™ Syringes provide accuracy of greater than 99%. Adjustable stops allow for fast,…
-
Reinforced plungers Cemented or removable needles Economical Similar to 800 series syringes, except these lower-cost syringes do not have adjustable plunger friction or a plunger stop. Order 8929F64 for replacement needle for removable needle syringes.