Hamilton
-
PICO 2 - board
HamiltonThe Hamilton PICO 2 - board is suitable for use with 5 - 100 uL SofTouch single/multi-channel pipette models.
-
Conductivity Standards
HamiltonHamilton offers conductivity standards whose stability of ±1% is guaranteed over a lifetime of up to 3 years. They can be used repeatedly under the condition that the bottle is not left open for more than 1 hour in total.
-
PRP-1 Reversed Phase HPLC Columns
HamiltonPolymeric 100 Å columns for general reversed phase separations. pH stable from 1 to 13 Better sample recovery than silica-based columns (there are no silanol groups) Excellent durability (stable to any concentration of water or organic solvent) Five particle…
-
Syringes
HamiltonThe 1700 series syringes are the gas tight version of the original 700 series syringes. This series of gas tight syringes is ideal for dispensing volumes from 1 µL up to 500 µL. A variety of different terminations and needle options are available in this series.
-
Syringe 725Npt5 250ul (22S/2"/5)
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. This series of syringes is ideal for dispensing volumes from 0.5 μL up to 500 μL. Stainless-steel plunger manufactured to fit the glass barrel with a tolerance smaller than 100 millionths of an inch, resulting in…
-
700 Series Microliter Syringes
HamiltonThe 700 series syringe is the original hand-fitted Hamilton syringe. The stainless steel plunger is manufactured to fit the glass barrel with a tolerance less than three thousandths of a millimeter, resulting in unsurpassed syringe life. This series of syringes is ideal for dispensing volumes from…
-
Cemented needles on 8928B58-64 Removable needles on 8928B67 Length: 2” Point style: 2 See 8928C40 for needle for 8928B67.
-
TLL Syringe
HamiltonThe Hamilton Super Syringe is a large volume Gastight syringe. These syringes are ideal for dispensing volumes from 50 mL up to 2 L. The Super Syringe is the only Hamilton syringe that is made with an acrylic barrel instead of a glass barrel.
-
Syringes & Accessories
HamiltonThe Hamilton barrel/plunger assembly is suitable for use with 25 uL 802RN syringe models. No needle included
-
1000µL Pipette Tips
HamiltonThese tips are used with Hamilton 1000 μL SoftGrip and SofTouch pipettes. They are provided in different packaging types, surface textures, and filter options.
-
Syringes & Accessories
HamiltonThe Hamilton plunger assembly is suitable for use with 1725 syringe models with TLLX/DX/CX terminations.
-
SoftGrip Adjustable Volume Pipettes
HamiltonWide selection of ergonomic pipettes Completely autoclavable Guaranteed accuracy and precision All pipettes have color-coded plunger buttons and labels for easy volume identification. SoftGrip air-displacement pipettes are built from high quality, state-of-the-art materials designed to provide…
-
Chromatography Syringes
Hamilton7000 Series Modified Microliter® Removable needles Replaceable barrels and parts No dead volume Positive displacement syringe for use with liquids. A tungsten plunger wire travels inside the needle, eliminating dead volume. Knurled hubs are used exclusively on the 7000…
-
-
SoftGrip Fixed-Volume Pipettes
HamiltonWide selection of ergonomic pipettes Completely autoclavable Guaranteed accuracy and precision All pipettes have color-coded plunger buttons and labels for easy volume identification. SoftGrip air-displacement pipettes are built from high quality, state-of-the-art materials designed to provide…
-
The Hamilton plunger assembly is suitable for use with 250 uL CTC syringe models.
-
Air Pump Seal
HamiltonThe Hamilton air pump seal is suitable for use with push-button hand probe which is used for large-volume sample dilutions.
-
Luer Lock Needles
HamiltonThe Large Hub Removable Needle (RN) is compatible with RN syringes from 250 µL to 10 mL and all SampleLock syringes. Needles are available from 26s to 20 gauge. All needles are sold in six-packs and the standard needles are 51 mm long. For all custom needles, the length and point style will need to…
-
SoftGrip Pipette Accessories
HamiltonThe Hamilton seal kit is suitable for use with 5 uL/10 uL SoftGrip single channel pipette models.
-
Syringes
HamiltonThe Hamilton 1000 series 2.5 mL syringe is suitable for use with large removable needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. It can be used at a pressure rating of up to 200 psig and temperature rating of up to 10 to 115 degree C.
-
The 1000 series syringe is a mid-volume Gastight syringe. Gastight syringes are ideal for dispensing both liquids and gases. They have a precision-machined polymer plunger tip, often PTFE, which creates a leak-free seal. With the tight fit, the tip essentially wipes the interior of the syringe…
-
PRP-X500 Anion Exchange Columns
HamiltonFast separations and good sample recovery PRP-X500 is a superficially porous polymeric anion exchange column designed for the separation, purification and isolation of proteins, peptides and DNA/RNA. The methacrylate polymeric coating of the PRP-X500 provides a more hydrophilic surface,…
-
Format: Guard Cartridge Holder Guard Column Size: Analytical Hardware Material: PEEK
-
Guard Colum Starter Kit
HamiltonGuard columns can provide many benefits when used upstream from an analytical, preparative, or semi-preparative column. Guard columns are typically chosen to have the same packing as the primary column. Any compounds or particulate material that would block the frits or highly adsorb to the primary…
-
Point styles 2 and 3 Standard 2” length Needles seat precisely to the zero graduation mark of the syringe. They are autoclavablewhen disassembled. They allow the use of different specification needles with the same barrel. The small ‘s’ next to the gauge number indicates…
-
Finger Grip
HamiltonThe Hamilton finger grip is suitable for use with SofTouch single channel models of up to 1000 uL.
-
HPLC Column
HamiltonHamilton PRP-3 columns are based off of the PRP-1 with a larger pore size for protein separation. This column resin has no silanol groups, so irreversible protein adsorption is not a concern, giving analytes such as proteins a recovery of > 90%. This stable material also allows the use of…
-
The Hamilton needle is suitable for use with CR-700-50/CR-700-200 constant rate syringe models.
-
-
PRP-X800 Cation Exchange Columns
HamiltonSeparates transition metals or mono and divalent cations in the same run. The PRP-X800 is a polymeric cation exchange column functionalized with itaconic acid that performs the isocratic separation of mono and divalent cations such as lithium, sodium, ammonium, potassium, magnesium and…
-
The Hamilton multi-channel cover is suitable for use with SoftGrip 8-channel 8 x 50 uL, 8 x 300 uL pipette models.
-
Syringes
HamiltonThe Hamilton 1700 series 10 uL syringe is suitable for use with cemented needles. This syringe model offers SST, borosilicate glass and PTFE fluid path. This 26s gauge syringe can be used at a pressure rating of up to 1000 psig and temperature rating of up to 10 to 50 degree C. Built-in chaney adapter