Cannon Instrument
-
CT-2000 Constant Temperature Bath
Cannon InstrumentMicroprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…
-
CBC Bath Coolers
Cannon InstrumentThermoelectrically cool baths up to 15°C below ambient 1/10 the size of standard refrigeration units Power consumption of only 250 watts Simple to operate with low maintenance Cooling fans are the only moving parts CBC bath coolers consist of a thermoelectric cooling unit and a separate…
-
Cannon Four Bulb Shear Dilution Viscometers
Cannon InstrumentFour Bulb Shear Dilution- Five-fold Dilution Type, Cannon CUSDC-11 Series For measurement of intrinsic viscosities extrapolated to zero shear rate Provides five-fold range of shear rates Design gives extra mechanical strength Negligible kinetic energy correction Precision:…
-
Viscometer Holder
Cannon InstrumentIncludes permanently attached round metal holder, for hole 51 mm (2 in) in diameter.
-
Cannon-Manning Vacuum, Cannon CMVC Series Viscometers
Cannon InstrumentCalibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…
-
BS/IP/SL Suspended Level Viscometer
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…
-
Modified Koppers Vacuum, Cannon Mkvc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of asphalt at 60°C (140°F) Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 42 to 200,000 poises. Two-piece design, with sample reservoir and calibrated capillary Vacuum of 300 mm Hg must be applied to top of capillary…
-
Paint Viscosity Standards
Cannon InstrumentFor Thomas®-Stormer® Viscometers Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate viscosity in centipoise and Krebs unit values at 25°C are given in table below. Actual value are furnished with each standard. Supplied in a one pint bottle.
-
Viscometer Calibration Size 200
Cannon InstrumentSimilar to Cannon-Manning Vacuum (CMV, 9724-H50) series, but with graduated capillary instead of two timing bulbs. Provided with certificate of calibration and instruction sheet. Viscosity range, poise: 2400 - 52000 Approx. constant poise/second at 300mm Hg Bulb B: 128 Approx.…
-
Cold Cranking Simulator Viscosity Standards
Cannon InstrumentConform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles
-
High-Temperature Viscosity Standards
Cannon InstrumentFor use with Cannon High Temperature/ High Shear Viscometers for measurements at 150°C and 10 -6 s -1 shear rate Based on NIST value of 1.0016 centipoise for water at 20°C; traceable to the NIST In accordance with ASTM Standard D 4624 9727U92 and U94 are non-Newtonian…
-
Flash Point Reference
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
Asphalt Institute Vacuum, Cannon Aivc Series Viscometers
Cannon InstrumentCalibrated viscometers For measuring viscosity of highly viscous materials such as asphalt cement at 60°C (140°F) Meets ASTM D 2171 Applicable to materials with viscosity range of 42 to 5,800,000 poises With graduated capillary to extend viscosity range of viscometer Minimum sample size: 3…
-
Certified Viscosity “Check Oils” for SAE Target Viscosities
Cannon InstrumentCANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…
-
Viscometer Holder
Cannon InstrumentAll Cannon viscometer holders fit holes 51 mm (2 inches) in diameter. Rubber holders are made of neoprene rubber. Plastic holders are self-aligning and hold the viscometer firmly by means of a spring clip. Metal holders are also self aligning, and are constructed of chrome-plated machined brass.…
-
Vacuum Manifold
Cannon InstrumentWith three or four manual valves for applying vacuum or pressure to capillary-type viscometers Designed for use with 9726T20 through 9726T67 Vacuum Regulators and Cannon-Manning, Asphalt Institute or Modified Koppers vacuum viscometers (see Thomas number 9724H50) Integral brackets permit…
-
Low-Temperature Viscosity Standards
Cannon InstrumentFor determining the viscosity of low-temperature gear oils and ATF fluids (see ASTM D 2983) Traceable to the NIST Viscosity 150,000 cP at temperature indicated in table below Offered in one pint bottles
-
Silicone Viscosity Standards
Cannon InstrumentFor calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…
-
CT-500 And CT-518 Constant Temperature Baths
Cannon InstrumentCT-500 Temperature range 20° to 100°C Easy temperature setting Precise solid state temperature control within 0.01°C Multiple safety features The top cover contains seven round holes 51 mm (2") in diameter. Each unit maintains accurate temperature control of 0.01°C within the range of…
-
General Purpose Low Temperature Viscosity Standards
Cannon InstrumentCANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…
-
Flash Point Reference Materials
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
Asphalt Institute Vacuum Viscometers
Cannon InstrumentThe Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…
-
Asphalt Institute Vacuum Viscometers
Cannon InstrumentThe Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…
-
Asphalt Institute Vacuum Viscometers
Cannon InstrumentThe Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…
-
Asphalt Institute Vacuum Viscometers
Cannon InstrumentThe Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…
-
Power Pack
Cannon InstrumentThe Cannon Instrument power pack is an ideal to have in any chemical laboratories, research facilities, manufacturing industries and pharmaceutical factories.
-
CMRV YS-30 Vics. Std 70 Pa
Cannon InstrumentFor CANNON Mini-Rotary Viscometer (CMRV) (see ASTM D 3829 and ASTM D 4684) Exhibits yield stress of 70 Pa ±35 Pa at –30°C
-
BS/IP/MSL Miniature Suspended Level Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of…
-
CMRV YS-35 Vics. Std 70 Pa
Cannon InstrumentFor CANNON Mini-Rotary Viscometer (CMRV) (see ASTM D 3829 and ASTM D 4684) Exhibits yield stress of 70 Pa ±35 Pa at –35°C
-
Drawer Unit for CT-500, CT-1000 and TE-1500
Cannon InstrumentSturdy two-drawer unit fits beneath the Constant Temperature Bath Provides elevated viewing of the bath and ample room for storage of viscometers and other accessories. Overall dimensions: 457 mm wide x 457 mm deep x 165 mm high. Weight: 24 lbs.
-
Asphalt Institute Vacuum Viscometers
Cannon InstrumentThe Asphalt Institute Vacuum viscometer measures the viscosity of highly viscous materials according to ASTM D2171. Minimum sample volume is 3 mL. Minimum bath depth is 180 mm (7.1 in). Viscometer is calibrated (the viscometer constant is the same at all temperatures) and provided with a…