Cannon Instrument
-
General Purpose Viscosity Standards
Cannon InstrumentBased on NIST value of 1.0016 centipoise for water at 20C; conforms to ASTM Standards D 445, D 88 and D 2161; traceable to NIST Approximate viscosities at varying temperatures in centistokes and centipoises are given in Table 1; each standard is furnished with actual viscosity and density…
-
Cannon-Fenske Series Viscometers
Cannon InstrumentCannon Fenske Routine, CFRU (Uncalibrated) & CFRC (Calibrated) Viscometers For measurement of kinematic viscosity of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 and ISO 3104 requirements Specifications conform to ASTM D 446 and…
-
Silicone Viscosity Standards
Cannon InstrumentFor calibration of rotational viscometers Viscosity certified at 20, 23, 24, 25, 26 and 27°C Calibrated to a precision of ±0.2% NIST traceable Standards are based on the National Institute of Standards and Technology (NIST) value of 1.0016 mPa-s (centipoise) for…
-
Flash Point Reference Materials
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
Cannon-Manning Vacuum, Cannon CMVC Series Viscometers
Cannon InstrumentCalibrated viscometers For measurement of viscosity of highly viscous materials such as asphalt cement at 140°F Meets ASTM Standard D 2171 Applicable to materials with viscosity range of 0.036 to 80,000 poise. Vacuum of 300 mm Hg is applied to small arm with timing bulbs; two…
-
Cannon-Ubbelohde, CUU And CUC Series Viscometers
Cannon InstrumentUncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at…
-
CT-2000 Constant Temperature Bath
Cannon InstrumentMicroprocessor controlled temperature regulation from 10 to 150°C Conforms to ASTM D 445 Built-in platinum resistance thermometer On-screen temperature monitoring RS 232 and RS 485 communication ports A keypad permits temperature selection to two decimal…
-
Cold Cranking Simulator Viscosity Standards
Cannon InstrumentConform to SAE specification J300 and ASTM D 5293 Viscosities based on NIST value of 1.0016 centipoise for water at 20°C Traceable to NIST Supplied in one pint bottles
-
CT-600 Constant Temperature Bath
Cannon InstrumentIdeal for kinematic viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features of…
-
Semi-Micro, Cannon CUSMC Series Viscometer
Cannon InstrumentCalibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic…
-
Vacuum Manifold
Cannon InstrumentWith three or four manual valves for applying vacuum or pressure to capillary-type viscometers Designed for use with 9726T20 through 9726T67 Vacuum Regulators and Cannon-Manning, Asphalt Institute or Modified Koppers vacuum viscometers (see Thomas number 9724H50) Integral brackets permit…
-
Zeitfuchs Cross-Arm Calibrated Viscometers
Cannon InstrumentCannon ZCAC Series For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445 specifications; also conform to ASTM Standard D 446 Precision: ±0.3% Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F (60°C) and…
-
TE-3000 Constant (Low) Temperature Bath
Cannon InstrumentFor glass capillary viscometers and other instruments requiring precise low temperature control All-digital, LCD displayed, microprocessor-controlled temperature regulation; Cooled thermoelectrically (solid state heat pump) Temperature range: -30°C to +30°C °C/°F…
-
CT-500 And CT-518 Constant Temperature Baths
Cannon InstrumentCT-500 Temperature range 20° to 100°C Easy temperature setting Precise solid state temperature control within 0.01°C Multiple safety features The top cover contains seven round holes 51 mm (2") in diameter. Each unit maintains accurate temperature control of 0.01°C within the range of…
-
Flash Point Reference
Cannon InstrumentCANNON Instrument Company can now provide Flash Point Reference Materials for calibrating Flash Point Testers. A total of six different standards are available for the following ASTM methods: ASTM D 56, ASTM D 92, and ASTM D 93. The data provided for each standard includes the average flash point…
-
Viscosity Standard, -20 and -25°C for CMRV, 500 ml
Cannon InstrumentFor preceding the borderline pumping temperature of engine oil in accordance of ASTM Standards D 3829 and D 4684 Viscosity of 30,000 centipoise at -20°C based on NIST value of 1.0016 centipoise for water at 20°C; traceable to NIST
-
TE-1500 Constant (Low) Temperature Bath
Cannon InstrumentDesigned specifically for measuring viscosity at low temperatures using glass capillary viscometers Conforms to ASTM D 445 for low temperature viscometry Peltier cell for thermoelectric cooling Fan-cooled, high-density heat sinks Holds two glass capillary viscometers A…
-
High Viscosity Standards
Cannon InstrumentFor determining viscosities in asphalt and polymers (see ASTM D 2170 and D 2171) Traceable NIST For Kinematic Viscosity Values (cSt), please contact Thomas Scientific
-
BS/U/M Miniature U-Tube
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of…
-
Bath Oil, 6-Gallon Container
Cannon InstrumentContains an oxidation inhibitor which reduces tendency to darken at higher temperatures For use below 135°C (275°F) For higher temperature requirements, see Thomas number 6428R25.
-
SimpleVIS™ Portable Viscometer
Cannon InstrumentQuick and reliable automation Direct kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3…
-
CT-1000 Constant Temperature Baths
Cannon InstrumentWide temperature range 20°C to 150°C Easy temperature setting Insulated for precise solid-state temperature control Multiple safety features Ideal for temperature control of other instruments which must be viewed while immersed in a constant temperature bath. The top…
-
General Purpose Low Temperature Viscosity Standards
Cannon InstrumentCANNON Low Temperature Viscosity Standards verify viscometer performance at sub-zero temperatures. These standards are applicable to SAE Specification J300 as well as a variety of ASTM Methods including: ASTM D2983, Low-Temperature Viscosity of Lubricants Measured by Brookfi eld…
-
BS/IP/RF U-Tube Reversed Flow Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes…
-
BS/U Tube Viscometers
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires…
-
Certified Viscosity “Check Oils” for SAE Target Viscosities
Cannon InstrumentCANNON Instrument Company has released a line of viscosity check oils specifically designed for verification of SAE target viscosities per ASTM D 445, D 5293, and D 4684. The CVCO (Certified Viscosity Check Oil) series includes formulated commercial engine oils with certified values for kinematic…
-
BS/IP/SL Suspended Level Viscometer
Cannon InstrumentCalibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ±0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”).…
-
Removable Viscometer Holders
Cannon InstrumentAll Cannon viscometer holders are designed to fit holes 51 mm (2 in.) in diameter. Rubber holders are made of neoprene rubber. Plastic holders hold the viscometer firmly with a spring clip. Metal holders are constructed of chrome-plated machined brass. A handle permits…
-
Solid Rubber Micro Stopper
Cannon InstrumentTapered from 6 mm top diameter to 2 mm bottom diameter, these solid rubber micro stoppers measure 20 mm long. Micro stoppers are for use with Cannon-Fenske Qpaque Viscometer and Cannon Cold-Cranking Simulator.
-
Ink and Paint Viscosity Standards
Cannon InstrumentFor ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished…
-
-
Cold-Cranking Simulator Standards
Cannon InstrumentCANNON CL Standards provide certified dynamic viscosity data (in cP or mPa·s) at temperatures from –5°C to –35°C. These standards are used to calibrate the CANNON Cold-Cranking Simulator (CCS) oil testing (see ASTM D 5293 and SAE Specification J300).