  • Most Widely used DPD Chlorine Tablets for Determining Free and Combined Chlorine DPD chlorine tablets employ DPD indicator (diethyl-p- phenylenediamine) to distinguish levels of free, combined, and total chlorine in a simple test sample. DPD chlorine tablets designated “Instrument…

  • A method for measuring the color of potable water in terms of an easily reproducible color standard is essential to water engineers responsible for the distribution of supplies for public consumption. Color determinations are useful for detecting any irregular contamination of the supply due…

  • Water hardness is caused almost entirely by calcium and magnesium ions. Other di- and trizalent metals have a similar effect, but usually are not present in high enough concentration in potable waters to cause problems. Hardness increases soap consumption in laundries and causes scale in boilers. …

  • Strips chemically treated with starch and cadmium iodide measure total chlorine to determine the strength of sanitizers in cleaning solutions. Furnished in plastic vial of 200 1/4” x 3 1/2” strips, with color comparison chart, which has three standards 50, 100 and 200 ppm

  • Because of its strong oxidizing properties, chlorine is an excellent biocide used to treat potable waters, municipal wastes, and swimming pools. When used to treat potable water, chlorine helps alleviate the adverse effects of iron, manganese, ammonia, and sulfide. The Maximum Residual Disinfectant…

  • Normally found in water and soil as ammonia (NH3), nitrate (NO3), and nitrite (NO2), nitrogen is an indispensable part of the life cycle. However, concentrations above certain levels can present problems. Thomas No. 3241S80 Utilizing the simple color…

  • Water Quality Testing. Dramatically Streamlined. The Hach SL1000 Portable Parallel Analyzer (PPA) performs the same tests with less than half the manual steps. Get highly accurate results, with less opportunity for errors, in a fraction of the time. Up to six parameters, tested…

  • This MEL provides all the hardware to carryout the Most Probable Number (MPN) method. In additon to potable water, the MPN method is ideal for wastewater samples and nonpotable samples, because the analyst can accomodate highly turbid samples which would otherwise require filtration. MEL/MPN Total…

  • DPD Powder Pop® Dispenser with tests for Chlorine Compact and convenient Redesigned dispenser prevents clogging Dispense into round or square cuvettes Push button operation for precise dosing Portable dispensers accurately deliver the correct volume of DPD reagent for…

  • Water hardness is caused almost entirely by calcium and magnesium ions. Other di- and trivalent metals have a similar effect, but usually are not present in high enough concentration in potable waters to cause problems. Hardness increases soap consumption in laundries and causes scale in boilers. …

  • Direct Reading Titrator (9860J75 and J76) For determining dissolved oxygen in natural and treated waters Employs azide modification of Winkler method Range from 0 to 10 ppm with 0.2 ppm sensitivity Sufficient for 50 tests at 10 ppm Ideal for daily monitoring or D.O. meter checkups and…

  • Iron is present in nature in the form of its oxides, or in combination with silicon or sulfur. The soluble iron content of surface waters rarely exceeds 1 mg/L, while ground waters often contain higher concentrations. The National Secondary Drinking Water Standard for iron is 0.3 mg/L, as iron…

  • This Chlorine test kit measures for Chlorine using the direct reading titrator method. Range/sensitivity is 0-10 ppm/0.2 ppm Cl. Applications: Drinking Water, Food and Beverage, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater # Tests (# Rgts): 50 at 10…

  • Use Hach's Patented Chemkey™ Technology with the SL1000 Portable Parallel Analyzer (PPA) for dramatically streamlined water quality testing. Chemkeys are a new technology from Hach that are designed for use with the SL1000-PPA Portable Parallel Analyzer. Same Trusted…

  • Waterworks Test Strips

    Industrial Test Systems

    Dip and read No mixing sample and reagent Economical, quick results Patented tests are quick alternatives for food or environmental testing. Supplied in bottles of 50 loose strips or packages of individually wrapped strips Tests for lead and other heavy metals

  • 3 ranges of PAA test strips available covering low (0-50 ppm), medium (0-160 ppm) and high (0- 1,000 ppm) range concentrations The Insta-Test® 3000 test strips determine peracetic acid concentrations from 0-160 ppm. The test has a 10 second development time. The container has a desiccant liner…

  • Insta-Test® strips are available to perform checks for water quality factors. Test strips are a quick way to monitor water without having to use reagents.

  • Chloride is found in nearly all natural waters and affects human taste above 250 mg/L. High levels inhibit plant growth, and many industrial processes need to limit chloride concentration. Contains 40 tests. Easy to use, disposable, and inexpensive A great way to obtain quick,…

  • The ColorQ Pool 4 measures four basic pool and spa tests, Free Chlorine (0 to 10 ppm); Total Chlorine (0 to 10 ppm); Bromine (0 to 22 ppm) and pH (6.5 to 8.5 pH). As a bonus, the ColorQ Pool 4 can also measure Total Alkalinity (Code 7038-G), Calcium Hardness (Code 7041-G and 7042-G), and Cyanuric…

  • For measuring water turbidity (cloudiness) according to either EPA or ISO Standards Easy Calibration and Operation Auto Ranging from 0-1100 NTU Simple 5 key operation Signal Averaging for stable and accurate readings Long Battery and Bulb Life Portable for use either in the…

  • Yes/No qualitative test Sensitivity less than 2.2 per 100 mL of sample No incubation equipment required; only room temperature

  • Sodium Test Kit

    LaMotte

    Direct Reading Titrator For determining levels of sodium in natural and treated waters Range 0 to 500 ppm sodium in 10 ppm increments Test requires three titrations: one to determine bicarbonate and carbonate ions; one to determine sulfate and chloride ions; and one to determine calcium and…

  • About Nitrogen, Ammonia A product of microbiological decay of plant and animal protein. Its presence in raw surface waters usually indicates domestic or agricultural pollution. Above certain levels, it is toxic to fish. Fast, reliable, and safe test strips from Hach: Hach Test Strips are easy…

  • For determination of Ammonia Nitrogen by the Salicylate Method, using TNTplus vials. Hach Method 10205. Ultra Low Range: 0.015 - 2.00 mg/L NH3-N. 25 tests/package Reduce Errors with Bar-coded Vials No Reagent Blank Necessary Innovative Vial and Reagent Delivery Helpful package…

  • The Model SD Monitoring Kit was specifically designed and manufactured to meet US EPA requirements for field test procedures approved in the Federal Register (Volume 55, No. 217), to monitor illicit storm drain connections. Each unit includes tests for pH, Total Chlorine, Total Copper, Phenols,…

  • Method: colorimetric with test strips and reagents 2 - 5 - 20 - 50 - 100 mg/l Mn MQuant™ UN Number: UN3316 Storage class: 8B Non-combustible, corrosive hazardous materials Storage: Store at +15°C to +25°C. Hazard: Corrosive The manganese test can be…

  • Biological Activity Reaction Test (BART) biodetectors are excellent microbiological diagnostic tools used to identify the presence of process disruptors. Find out if you have bacteria creating slime layers and limiting disinfection, or if iron-reducing bacteria are corroding your pipes. Tests for…

  • This kit tests for nitrate nitrogen using the LRC Comparator. Range/sensitivity is 0, 0.2, 0.4, 0.6, 0.8, 1.0 ppm NO3--N. Applications: Food and Beverage, Environmental Education, Industrial Water Boiling and Cooling, Laundry and Sanitation, Water and Wastewater

  • Chlorine dioxide is used as an oxidizing microbiocide in industrial cooling water treatment, the dairy industry, the meat industry, and many other food and beverage industry applications. It is used as a bleaching agent in the pulp and paper industry, and as a disinfectant in municipal water…

  • No. 7436-01 Determines corrosion conditions in water supplies which can introduce lead and heavy metals Supports a water supplier’s lead abatement program in drinking water Includes TDS pocket tester to meet EPA requirements for corrosion testing Packaged in a portable…