MilliporeSigma Chromatography Vials
-
Vial crimp seals, BiMetal (magnetic)
MilliporeSigmaThe BiMetal caps are made of both tin and aluminum and are easier to crimp than tin 20mm seals. The sealing surface is aluminum and the inner diameter is made of tin to add the magnetic surface. These caps are available in a variety of colors. Other Notes: We recommend using the plier-type…
-
MSQ(TM) Caps with Septa
MilliporeSigmaWe recommend using LA Vials with the MSQ polypropylene cap with PTFE/silicone septa. This cap and septa combination was purposely designed for use with mass spectrometry. It shows little to no background contamination when compared to other cap and septa products in the marketplace. Legal…
-
Vials, screw-top
MilliporeSigmaGraduated. Autoclavable borosilicate USP Type 1 glass. PTFE faced rubber septum. Legal Information: V-Vial is a registered trademark of Wheaton Industries, Inc.
-
Screw cap black polypropylene
MilliporeSigmaApplication: Screw cap may be used for capping water samples in amber glass vial comprising of a polytetrafluoroethylene silicon septum for the analysis of chlorinated volatile organic compounds in water samples using headspace-solid-phase microextraction with gas chromatography (HS-SPME-GC).
-
-
Certified QSertVial(TM) (vial with fused-in insert) kit
MilliporeSigmaThe QSertVial(TM) is the ultimate microsampling device. It contains a 300 muL glass insert that is fused to the vial to form one precise integral unit. The rim of the insert is positioned slightly above the top of the vial so the septum can make a secure seal with the closure, eliminating…
-
Vials, crimp top
MilliporeSigmaThese vials are constructed of clear, borosilicate glass; closure not included.
-
Septa, PTFE/Silicone transparent PTFE/silicone
MilliporeSigmaApplication: Septa, PTFE/Silicone have been used to seal the headspace vial in the determination of methylene chloride in urine samples by solid-phase microextraction technique combined with gas chromatography.
-
Headspace vial, clear glass
MilliporeSigmaApplication: Headspace vial may be used in storing samples for stability analysis of freeze dried and fluid bed dried alginate microcapsules coated with chitosan containing model probiotic bacteria, Lactobacillus plantarum.
-
Vials, screw top
MilliporeSigmaVials (volume 15 mL, clear glass vial, O.D. x H 21 mm x 70 mm) are suitable basically to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials. Synonyms: PK100 15ML CLEAR VIAL,SCREW TOP,SOLID…
-
Wheaton sample vials with rubber lined caps
MilliporeSigmaCaps have white styrene-butadiene rubber liner and are packed in Lab-File® cases. Clear Wheaton-33, low extractable borosilicate glass or amber Wheaton-320 glass. Can be sterilized and stored at low temperatures. Legal Information: Lab File is a registered trademark of Wheaton Industries, Inc.
-
Septa, Blue PTFE/white silicone
MilliporeSigmaApplication: Septa, blue PTFE/white silicone (blue PTFE/white silicone) has been used as a part of injection port in the gas chromatographic (GC) analysis of nitrous oxide, methane and carbon-dioxide gases in soil samples subjected to irrigation.
-
Black plastic caps Solid top
MilliporeSigmaThese autoclavable caps are designed to ensure the ultimate in product safety.
-
Vials, screw top with solid green Thermoset cap
MilliporeSigmaSynonyms: PK100 2ML AMBER VIAL,SCREW TOP, SOLID CAP W/PTFE LINER
-
Standard screw-thread autosampler vials
MilliporeSigmaConstructed of borosilicate glass. Vials use 8mm septa and screw-caps
-
Insert for 2 mL standard opening vial
MilliporeSigmaVial inserts allow the use of smaller sample volumes with standard autosampler vials. Inserts are generally chosen based on the inner diameter of the vial neck. Standard opening vials (4.6 mm ID) require a 5 mm OD insert.
-
Application: It may be used to cut and store fresh plant material for collecting volatiles in solid phase microextraction (SPME) technique. It may also be used in liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining bisphenol A, 4-t-octylphenol and 4-nonylphenol in…
-
Vials, screw top
MilliporeSigmaVials (volume 7 mL, clear glass vial, O.D. x H 17 mm x 60 mm, tan PTFE/silicone septum) are suitable basically to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials. Caps are made from phenolic…
-
ABC Vial™
MilliporeSigmaLegal Information: ABC Vial is a trademark of Wheaton Industries, Inc. Other Notes: The diameter of inserts varies between manufacturers. Only the following insert part numbers are compatible with these large opening vials. •24719, 24720 Glass insert, conical bottom, 6 x 29mm •24721 Glass…
-
Vials, screw top, R.A.M.(TM)
MilliporeSigma•Compatible with robotic arm autosamplers •Replaces crimp top autosampler vials •Large target area for needle •Utilizes Step Vial design to center insertThe R.A.M.TM (robotic arm machine) vial is specifically designed to work with a robotic arm autosampler. This 12 x 32 mm vial has a shortened…
-
Vials Inserts
MilliporeSigmaMicro volume vial inserts, when used in conjunction with autosampler vials, allow for maximum sample recovery and easier sample removal. Vial inserts (volume 0.15 mL, glass insert (with bottom spring), O.D. x H 6 mm x 38 mm) allow the use of smaller sample volumes with standard autosampler vials.…
-
Mininert® Valve
MilliporeSigmaThese valves are very easy to use: 1. Push the green button to open the valve 2. Insert the needle through the septum and take sample 3. Remove the needle and push to closeBenefits include: •PTFE construction for inertness. PTFE is useful when working when acids and organic solvents…
-
Liquid scintillation vials
MilliporeSigmaReliable Wheaton "180" brand low-potassium glass. White 22 mm caps have tops suitable for writing. Vials with caps attached are packed in individual cells in trays of 100.
-
Application: It may be used to cut and store fresh plant material for collecting volatiles in solid phase microextraction (SPME) technique. It may also be used in liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for determining bisphenol A, 4-t-octylphenol and 4-nonylphenol in…
-
Liquid scintillation vials
MilliporeSigmaWheaton 180 brand low-potassium glass yielding consistent low backgrounds and high UV transmission. White caps fit tightly and can be written on.
-
Interlocked vial with fused glass insert
MilliporeSigmaThe new Interlock Vial/Insert limited volume vial is a 300 muL flange top glass insert permanently fused into 12 x 32 mm glass vials. This product provides the user with the convenience and performance of a one piece microvial at a fraction of the cost. •The flange top centers the inserts into the…
-
Liquid scintillation vials
MilliporeSigmaReliable Wheaton "180" brand low-potassium glass. White 22 mm caps have tops suitable for writing. Vials with caps attached are packed in individual cells in trays of 100.
-
Vials, screw top with phenolic open-top cap, pre-assembled
MilliporeSigmaVials are used basically to inject samples from an autosampler. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials. Screw top glass vials are used on many autosamplers with a standard opening of 4.6 mm. Amber glass prevents the…
-
Space Saver storage racks
MilliporeSigmaEconomical and convenient storage for samples in your screw cap and crimp seal vials. Can be stacked when empty or full. Autoclavable, 120C. Each case contains 5 racks. Synonyms: VIAL RACK,40ML EPA VIAL, 5/CS Legal Information: WHEATON is a registered trademark of Wheaton Industries, Inc.
-
Headspace vial, clear glass
MilliporeSigmaApplication: Headspace vial may be used in storing samples for stability analysis of freeze dried and fluid bed dried alginate microcapsules coated with chitosan containing model probiotic bacteria, Lactobacillus plantarum. Legal Information: WHEATON is a registered trademark of Wheaton…
-
Vials, screw top, clear glass
MilliporeSigmaVials are suitable basically to inject samples from an autosampler. They are varied in sizes, though 2 mL vials are more commonly used. Autosampler needle pierces through the cap during injection and withdraws the required aliquots of sample from the vials. Application: Clear glass, screw top…
-
Headspace vial, screw top, rounded bottom
MilliporeSigmaThese vials require a special cap with an 18 mm thread. The standard 18-400 threaded caps will not fit this vial. The part numbers for caps that are available for these vials are SU860101(with PTFE/silicone, 1.3 mm thick), SU860102 (with PTFE/butyl, 1.6 mm thick), and SU860103 (with PTFE/silicone,…