Chromatography Tubes, Tubes
-
GBC Standard Graphite Tube, Pyrolytically Coated
PerkinElmerThe GBC Standard Graphite Tube is pyrolytically coated, D7/3.7x24.2 mm and comes in a quantity of 10. This tube is fit to perform on a GBC atomic absorption (AA) instrument and is the equivelant of GBC part 99-0059-00.
-
The graphite tube, the heart of the graphite furnace, plays a vital role in the overall stability of an analysis. In order to assure stable analytical conditions from one atomization cycle to the next, and from graphite tube to graphite tube, all graphite parts - contacts, tubes and platforms -…
-
Assay Tubes
G-BiosciencesWide bottomed protein assay tubes, 2ml reaction volumes. Allows proper mixing of assay reaction and good color development.
-
Inoculating Loops and Needles
MTC BioThese sterile disposable plastic loops and needles are designed for use in quantitative procedures such as sampling, urine counts and serial dilutions, as well as for bacterial inoculation. Because they are pre-sterilized and designed for single use, t
-
The exceptionally uniform temperature distribution obtained with transverse heating significantly reduces or eliminates condensation of the sample matrix components and "memory" effects and improves the atomization efficiency for refractory elements. For improved characteristic mass with volatile…
-
The new Advanced Platform design suspends the platform in the tube using three small pins in a triangular layout. This has the advantage of minimizing wall contact and reducing thermal conduction from the tube walls resulting in even and rapid heating almost exclusively from thermal radiation, an…
-
The spherically shaped platform accommodates up to 50 µL of sample. Graphite tubes with integrated platforms: Provide STPF conditions for volatile and nonvolatile refractory elements due to the significantly higher heating rates of tube and platform, which can be used for all elements. Offer an…
-
Standard HGA Graphite Walled Tubes
PerkinElmerThese HGA graphite walled tubes are pyrocoated to provide improved sensitivity and tube-to-tube reproducibility. The walled tube should be used in place of L'vov platform tubes when analyzing refractory elements such as Vanadium. NOTE: The tubes do not have an integrated platform and are not…
-
-
BioReactors Fixed Height Sample Tubes
ChemglassFixed height sampling tubes for bioreactors. Tubing is 1/4 inch OD.Like-for-like replacement parts for Applikon® Biotechnology and Broadley-James® brands of bioreactors.Applikon® is a registered trademark of Applikon Biotechnology, Inc. Broadley-James® and Broadley-James…
-
Thermo Electron Omega Graphite Tube
PerkinElmerThermo Electron Omega Graphite Tubes are compatible with your Thermo Electron atomic absorption instrument.
-
Overhead Drive
ChemglassADDITION DIP TUBE ASSEMBLIES, 3-PORT, SST, WITH HOSE BARBSOur hose barbed 3-port dip tube assemblies are designed for addition or sampling of media from Vertical Side Arm (VSA) Bioreactor Vessels. These addition dip tube assemblies are ideal for liquid addition of acid, base, antifoam or media.…
-
Bio Reactor Adjustable Sampling Tubes
ChemglassThese sampling tubes are adjustable to permit the culture fluid to be sampled at any desired level. Tubing is 1/4” OD.Like-for-like replacement parts for Applikon® Biotechnology and Broadley-James® brands of bioreactors.Applikon® is a registered trademark of Applikon…
-
The exceptionally uniform temperature distribution obtained with transverse heating significantly reduces or eliminates condensation of the sample matrix components and "memory" effects and improves the atomization efficiency for refractory elements. For improved characteristic mass with volatile…
-
FIAS-Furnace Sample Transfer Tube, Included in the kit (P/N B3140255)
-
Quartz Tube with Au/Pt Gauze for Amalgamation System
-
For the lowest possible detection limits, residual contaminant levels may not be low enough to meet your requirements. UltraClean graphite tubes offer unmatched analytical advantages for special applications such as the determination of extremely low traces of Na, Ca, Fe, Cr and Ni in ultra-clean…
-
The partition graphite tube for Agilent is pyrolytically coated, D6. 9/3. 9x24. 9 mm and comes in a quantity of 10. It has an extended life and is fit to perform on atomic absorption (AA) instruments for Agilent. The extended life partition graphite tube is equivalent to Agilent part 63-100012-EL.
-
These tubes are fit to perform on atomic absorption (AA) instruments for Agilent and is equivalent to Agilent/Varian part 63-100037-00. PerkinElmer supplies a wide range of graphite tubes for non-PerkinElmer instrumentation. Graphite tubes are made with the highest quality material guaranteed to…
-
The new Advanced Platform design suspends the platform in the tube using three small pins in a triangular layout. This has the advantage of minimizing wall contact and reducing thermal conduction from the tube walls resulting in even and rapid heating almost exclusively from thermal radiation, an…
-
We offer fit-to-perform Shimadzu Pyrolytically-Coated Graphite Tubes with Built-in Platforms, equivalent to Shimadzu part 206-5887-02RI.
-
Standard Graphite Tubes for Shimadzu
PerkinElmerThese tubes are fit to perform on atomic absorption (AA) instruments for Shimadzu, are pyrocoated, have a 90° contact cone and are equivalent to Shimadzu part 206-50588. PerkinElmer supplies a wide range of graphite tubes for non-PerkinElmer instrumentation. Graphite tubes are made with the…
-
Exhaust Tube 1.5 m for Titan MPS
PerkinElmerUsed with optional accessory for exhausting Titan MPS oven cavity in laboratories that do not have exhaust systems. Exhaust Tube 1. 5 m (ID 76 mm, OD 82 mm) (one included with Titan MPS)
-
The Shimadzu Uncoated Standard Graphite Tube is fit-to-perform on a Shimadzu atomic absorption instrument and is equivalent to Shimadzu part 206-50587.
-
-
The new Advanced Platform design suspends the platform in the tube using three small pins in a triangular layout. This has the advantage of minimizing wall contact and reducing thermal conduction from the tube walls resulting in even and rapid heating almost exclusively from thermal radiation, an…
-
Needle Port Tube for Rheodyne Injection Valves, Model 9725/8125/7125/7725
-
ESI Needle (Tube)
PerkinElmerThe innovative separation probes and holders facilitate chromatography directly at the ionization source. This minimizes dead volume effects in the system for superior signal-to-noise ratios, enhanced sensitivity and narrower peaks. Compatible with LC/MS systems using Flexar SQ300 or AxION 2 TOF MS.
-
Standard HGA Graphite Tubes with Lvov Groove
PerkinElmerThese HGA graphite tubes are pyrocoated to provide improved sensitivity and tube-to-tube reproducibility. They are slotted to accept L'vov platforms, PerkinElmer part number B3001256. PerkinElmer has over four decades of experience in the design/development of graphite furnace systems and…
-
Air Aeration Tube with Sparger
ChemglassThe 15 micron, sintered metal tip produces tiny air bubbles for optimum gas distribution. The “A” dimension listed allows for placement in different ports of the headplate. NOTE: Replacement O-Ring listed is for M10 connection.Like-for-like replacement parts for Applikon®…
-
Standard HGA Graphite Tubes with Lvov Groove
PerkinElmerThese HGA graphite tubes are pyrocoated to provide improved sensitivity and tube-to-tube reproducibility. They are slotted to accept L'vov platforms, PerkinElmer part number B3001256. PerkinElmer has over four decades of experience in the design/development of graphite furnace systems and…
-
The new Advanced Platform design suspends the platform in the tube using three small pins in a triangular layout. This has the advantage of minimizing wall contact and reducing thermal conduction from the tube walls resulting in even and rapid heating almost exclusively from thermal radiation, an…